1 – 28 of 28
- show: 250
- |
- sort: year (new to old)
- |
- Export
- 2015
- Kan preventie gezondheidsverschillen verkleinen?: impact van populatiegerichte interventies op sociale ongelijkheid (2015) HUISARTS NU. 44(1). p.20-22
- 2013
- Preventieve interventies door een equity-bril: een gelijke gezondheidswinst voor iedereen? (2013) HUISARTS NU. 42(5). p.233-238
- 2007
- Mathematical modeling of ventricular assist devices (2007) Cardiac perfusion and pumping engineering. In Clinically-Oriented Biomedical Engineering 1. p.419-475
- 2006
- Modeling ventricular function during cardiac assist: Does time-varying elastance work? (2006) ASAIO JOURNAL. 52(1). p.4-8
- 2005
- Accuracy of 4 different algorithms for the analysis of tomographic radionuclide ventriculography using a physical, dynamic 4-chamber cardiac phantom (2005) JOURNAL OF NUCLEAR MEDICINE. 46(1). p.165-171
- Hemodynamic modes of ventricular assist with a rotary blood pump: Continuous, pulsatile, and failure. (2005) ASAIO JOURNAL. 51(6). p.711-718
- 2004
- Accuracy of commercially available processing algorithms for planar radionuclide ventriculography using data for a dynamic left ventricular phantom. (2004) NUCLEAR MEDICINE COMMUNICATIONS. 25(12). p.1197-1202
- In vitro assessment of the unloading and perfusion capacities of the PUCA II and the IABP. (2004) PERFUSION-UK. 19(1). p.25-32
- Model dependence of gated blood pool SPECT ventricular function measurements (2004) JOURNAL OF NUCLEAR CARDIOLOGY. 11(3). p.282-292
- The impact of pump speed and inlet cannulation site on left ventricular unloading with a rotary blood pump (2004) ARTIFICIAL ORGANS. 28(7). p.660-667
- Hydraulic bench testing of the TruCATH/TruCCOM Continuous Cardiac Output Monitor (2004) CARDIOVASCULAR ENGINEERING. 3(3). p.93-102
- The impact of pump speed and inlet cannulation site on left ventricular unloading with a rotary blood pump (2004) ESB 2004.
- Modeling the interaction between cardiac assist devices and the left ventricle (2004)
- 2003
- In vitro evaluation of the PUCA II intra-arterial LVAD (2003) INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. 26(8). p.743-752
- Unloading effect of a rotary blood pump assessed by mathematical modeling (2003) ARTIFICIAL ORGANS. 27(12). p.1094-1101
- Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom (2003) JOURNAL OF NUCLEAR MEDICINE. 44(6). p.967-972
- Validation of planar and tomographic radionuclide ventriculography by a dynamic ventricular phantom (2003) NUCLEAR MEDICINE COMMUNICATIONS. 24(7). p.771-777
- A comparison of PUCA II LVAD and IABP for cardiac unloading and perfusion in an in vitro setup (2003) ASAIO JOURNAL. 49(2). p.158-158
- A comparison of PUCA II LVAD and IABP for cardiac unloading and perfusion in an in vitro setup (2003) ARTIFICIAL ORGANS. 27(4). p.318-318
- Cardiac unloading and perfusion achieved with the PUCA II system and an IABP: a comparative in vitro study (2003) Proceedings of the XXXVIII Congres of the European Society for Surgical Research. p.215-216
- Unloading and perfusion capacities of the IABP and PUCA II assist systems (2003) Abstracts of the 10th FECECT congress. p.16-16
- 2002
- Design of a new pulsatile bioreactor for tissue engineered aortic heart valve formation (2002) ARTIFICIAL ORGANS. 26(8). p.710-714
- Effect of rotary blood pump failure on left ventricular energetics assessed by mathematical modeling. (2002) ARTIFICIAL ORGANS. 26(12). p.1032-1039
- Mock loop testing of On-X prosthetic mitral valve with Doppler echocardiography. (2002) ARTIFICIAL ORGANS. 26(10). p.872-878
- Omnicarbon (TM) 21 mm aortic valve prosthesis: In vitro hydrodynamic and echo-doppler study. (2002) INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. 25(8). p.783-790
- 2001
- Hydrodynamic characterisation of ventricular assist devices. (2001) INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. 24(7). p.470-477
- 'Development of pulsatile bioreactor for the in vitro formation of tissue engineered heart valves'. (2001) TECHNOLOGY AND HEALTH CARE. 9(2. p.66-68
- Characterisation of cardiac assist devices. (2001) TECHNOLOGY AND HEALTH CARE. 9(2). p.70-72