Evaluation of in-line spatial filter velocimetry as PAT monitoring tool for particle growth during fluid bed granulation

Author
Organization
Keywords
NEAR-INFRARED SPECTROSCOPY, END-POINT DETERMINATION, HIGH-SHEAR GRANULATION, IMAGE-PROCESSING SYSTEM, Spatial filter velocimetry (SFV), Particle size (distribution), Process understanding, Fluid bed granulation, In-line measurements, Process analytical technology (PAT), SIZE DISTRIBUTION, VALIDATION, MOISTURE, VELOCITY, PROBE, SHAPE

Downloads

  • Evaluation.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 275.46 KB
  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 663.54 KB

Citation

Please use this url to cite or link to this publication:

MLA
Burggraeve, Anneleen et al. “Evaluation of In-line Spatial Filter Velocimetry as PAT Monitoring Tool for Particle Growth During Fluid Bed Granulation.” EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS 76.1 (2010): 138–146. Print.
APA
Burggraeve, A., Van Den Kerkhof, T., Hellings, M., Remon, J. P., Vervaet, C., & De Beer, T. (2010). Evaluation of in-line spatial filter velocimetry as PAT monitoring tool for particle growth during fluid bed granulation. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 76(1), 138–146.
Chicago author-date
Burggraeve, Anneleen, Tom Van Den Kerkhof, Mario Hellings, Jean Paul Remon, Chris Vervaet, and Thomas De Beer. 2010. “Evaluation of In-line Spatial Filter Velocimetry as PAT Monitoring Tool for Particle Growth During Fluid Bed Granulation.” European Journal of Pharmaceutics and Biopharmaceutics 76 (1): 138–146.
Chicago author-date (all authors)
Burggraeve, Anneleen, Tom Van Den Kerkhof, Mario Hellings, Jean Paul Remon, Chris Vervaet, and Thomas De Beer. 2010. “Evaluation of In-line Spatial Filter Velocimetry as PAT Monitoring Tool for Particle Growth During Fluid Bed Granulation.” European Journal of Pharmaceutics and Biopharmaceutics 76 (1): 138–146.
Vancouver
1.
Burggraeve A, Van Den Kerkhof T, Hellings M, Remon JP, Vervaet C, De Beer T. Evaluation of in-line spatial filter velocimetry as PAT monitoring tool for particle growth during fluid bed granulation. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS. 2010;76(1):138–46.
IEEE
[1]
A. Burggraeve, T. Van Den Kerkhof, M. Hellings, J. P. Remon, C. Vervaet, and T. De Beer, “Evaluation of in-line spatial filter velocimetry as PAT monitoring tool for particle growth during fluid bed granulation,” EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, vol. 76, no. 1, pp. 138–146, 2010.
@article{978837,
  author       = {Burggraeve, Anneleen and Van Den Kerkhof, Tom and Hellings, Mario and Remon, Jean Paul and Vervaet, Chris and De Beer, Thomas},
  issn         = {0939-6411},
  journal      = {EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS},
  keywords     = {NEAR-INFRARED SPECTROSCOPY,END-POINT DETERMINATION,HIGH-SHEAR GRANULATION,IMAGE-PROCESSING SYSTEM,Spatial filter velocimetry (SFV),Particle size (distribution),Process understanding,Fluid bed granulation,In-line measurements,Process analytical technology (PAT),SIZE DISTRIBUTION,VALIDATION,MOISTURE,VELOCITY,PROBE,SHAPE},
  language     = {eng},
  number       = {1},
  pages        = {138--146},
  title        = {Evaluation of in-line spatial filter velocimetry as PAT monitoring tool for particle growth during fluid bed granulation},
  url          = {http://dx.doi.org/10.1016/j.ejpb.2010.06.001},
  volume       = {76},
  year         = {2010},
}