The kinetic plot method applied to gradient chromatography: theoretical framework and experimental validation
- Author
- K Broeckhoven, D Cabooter, Frederic Lynen (UGent) , Patrick Sandra (UGent) and G Desmet
- Organization
- Keywords
- PEAK-CAPACITY, CONVENTIONAL COLUMNS, PERFORMANCE LIQUID-CHROMATOGRAPHY, PACKED CAPILLARY COLUMNS, TEMPERATURE, SPEED, STATIONARY PHASES, PARTICLE-SIZE, ELUTION, HIGH-PRESSURE, Numerical simulation, Peak compression, Band broadening, Gradient elution, Kinetic performance
Downloads
-
(...).pdf
- full text
- |
- UGent only
- |
- |
- 434.03 KB
-
Grad Kin plot non edited.pdf
- full text
- |
- open access
- |
- |
- 823.34 KB
Citation
Please use this url to cite or link to this publication: http://hdl.handle.net/1854/LU-966839
- MLA
- Broeckhoven, K., et al. “The Kinetic Plot Method Applied to Gradient Chromatography: Theoretical Framework and Experimental Validation.” JOURNAL OF CHROMATOGRAPHY A, vol. 1217, no. 17, 2010, pp. 2787–95, doi:10.1016/j.chroma.2010.02.023.
- APA
- Broeckhoven, K., Cabooter, D., Lynen, F., Sandra, P., & Desmet, G. (2010). The kinetic plot method applied to gradient chromatography: theoretical framework and experimental validation. JOURNAL OF CHROMATOGRAPHY A, 1217(17), 2787–2795. https://doi.org/10.1016/j.chroma.2010.02.023
- Chicago author-date
- Broeckhoven, K, D Cabooter, Frederic Lynen, Patrick Sandra, and G Desmet. 2010. “The Kinetic Plot Method Applied to Gradient Chromatography: Theoretical Framework and Experimental Validation.” JOURNAL OF CHROMATOGRAPHY A 1217 (17): 2787–95. https://doi.org/10.1016/j.chroma.2010.02.023.
- Chicago author-date (all authors)
- Broeckhoven, K, D Cabooter, Frederic Lynen, Patrick Sandra, and G Desmet. 2010. “The Kinetic Plot Method Applied to Gradient Chromatography: Theoretical Framework and Experimental Validation.” JOURNAL OF CHROMATOGRAPHY A 1217 (17): 2787–2795. doi:10.1016/j.chroma.2010.02.023.
- Vancouver
- 1.Broeckhoven K, Cabooter D, Lynen F, Sandra P, Desmet G. The kinetic plot method applied to gradient chromatography: theoretical framework and experimental validation. JOURNAL OF CHROMATOGRAPHY A. 2010;1217(17):2787–95.
- IEEE
- [1]K. Broeckhoven, D. Cabooter, F. Lynen, P. Sandra, and G. Desmet, “The kinetic plot method applied to gradient chromatography: theoretical framework and experimental validation,” JOURNAL OF CHROMATOGRAPHY A, vol. 1217, no. 17, pp. 2787–2795, 2010.
@article{966839, author = {{Broeckhoven, K and Cabooter, D and Lynen, Frederic and Sandra, Patrick and Desmet, G}}, issn = {{0021-9673}}, journal = {{JOURNAL OF CHROMATOGRAPHY A}}, keywords = {{PEAK-CAPACITY,CONVENTIONAL COLUMNS,PERFORMANCE LIQUID-CHROMATOGRAPHY,PACKED CAPILLARY COLUMNS,TEMPERATURE,SPEED,STATIONARY PHASES,PARTICLE-SIZE,ELUTION,HIGH-PRESSURE,Numerical simulation,Peak compression,Band broadening,Gradient elution,Kinetic performance}}, language = {{eng}}, number = {{17}}, pages = {{2787--2795}}, title = {{The kinetic plot method applied to gradient chromatography: theoretical framework and experimental validation}}, url = {{http://doi.org/10.1016/j.chroma.2010.02.023}}, volume = {{1217}}, year = {{2010}}, }
- Altmetric
- View in Altmetric
- Web of Science
- Times cited: