Advanced search
1 file | 382.51 KB Add to list

An assessment of ductus venosus tapering and wave transmission from the fetal heart

Author
Organization
Abstract
Pressure and flow pulsations in the fetal heart propagate through the precordial vein and the ductus venosus (DV) but are normally not transmitted into the umbilical vein (UV). Pulsations in the umbilical vein do occur, however, in early pregnancy and in pathological conditions. Such transmission into the umbilical vein is not well understood. In particular, the effect of the impedance changes in the DV due to its tapered geometry is not known. This paper presents a mathematical model that we developed to study the transmission of pulsations, originating in the fetal heart, through the DV to the umbilical vein. In our model, the tapered geometry of the DV was found to be of minor importance and the only effective reflection site in the DV appears to be at the DV inlet. Differences between the DV inlet and outlet flow were also found to be minor for medium to large umbilical vein-DV diameter ratios. Finally, the results of a previously proposed lumped model were found to agree well with the present model of the DV-umbilical vein bifurcation.
Keywords
UMBILICAL VEIN, SHEEP, HUMAN FETUS, BIFURCATION, PULSATIONS, CIRCULATION, SIMULATION, Reflection, Ductus venosus, Wave propagation, VELOCITY, LIVER, BLOOD-FLOW

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 382.51 KB

Citation

Please use this url to cite or link to this publication:

MLA
Hellevik, Leif Rune, et al. “An Assessment of Ductus Venosus Tapering and Wave Transmission from the Fetal Heart.” BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, vol. 8, no. 6, 2009, pp. 509–17, doi:10.1007/s10237-009-0155-4.
APA
Hellevik, L. R., Vierendeels, J., Kiserud, T., Stergiopulos, N., Irgens, F., Dick, E., … Verdonck, P. (2009). An assessment of ductus venosus tapering and wave transmission from the fetal heart. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 8(6), 509–517. https://doi.org/10.1007/s10237-009-0155-4
Chicago author-date
Hellevik, Leif Rune, Jan Vierendeels, T Kiserud, N Stergiopulos, F Irgens, Erik Dick, K Riemslagh, and Pascal Verdonck. 2009. “An Assessment of Ductus Venosus Tapering and Wave Transmission from the Fetal Heart.” BIOMECHANICS AND MODELING IN MECHANOBIOLOGY 8 (6): 509–17. https://doi.org/10.1007/s10237-009-0155-4.
Chicago author-date (all authors)
Hellevik, Leif Rune, Jan Vierendeels, T Kiserud, N Stergiopulos, F Irgens, Erik Dick, K Riemslagh, and Pascal Verdonck. 2009. “An Assessment of Ductus Venosus Tapering and Wave Transmission from the Fetal Heart.” BIOMECHANICS AND MODELING IN MECHANOBIOLOGY 8 (6): 509–517. doi:10.1007/s10237-009-0155-4.
Vancouver
1.
Hellevik LR, Vierendeels J, Kiserud T, Stergiopulos N, Irgens F, Dick E, et al. An assessment of ductus venosus tapering and wave transmission from the fetal heart. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY. 2009;8(6):509–17.
IEEE
[1]
L. R. Hellevik et al., “An assessment of ductus venosus tapering and wave transmission from the fetal heart,” BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, vol. 8, no. 6, pp. 509–517, 2009.
@article{911611,
  abstract     = {{Pressure and flow pulsations in the fetal heart propagate through the precordial vein and the ductus venosus (DV) but are normally not transmitted into the umbilical vein (UV). Pulsations in the umbilical vein do occur, however, in early pregnancy and in pathological conditions. Such transmission into the umbilical vein is not well understood. In particular, the effect of the impedance changes in the DV due to its tapered geometry is not known. This paper presents a mathematical model that we developed to study the transmission of pulsations, originating in the fetal heart, through the DV to the umbilical vein. In our model, the tapered geometry of the DV was found to be of minor importance and the only effective reflection site in the DV appears to be at the DV inlet. Differences between the DV inlet and outlet flow were also found to be minor for medium to large umbilical vein-DV diameter ratios. Finally, the results of a previously proposed lumped model were found to agree well with the present model of the DV-umbilical vein bifurcation.}},
  author       = {{Hellevik, Leif Rune and Vierendeels, Jan and Kiserud, T and Stergiopulos, N and Irgens, F and Dick, Erik and Riemslagh, K and Verdonck, Pascal}},
  issn         = {{1617-7959}},
  journal      = {{BIOMECHANICS AND MODELING IN MECHANOBIOLOGY}},
  keywords     = {{UMBILICAL VEIN,SHEEP,HUMAN FETUS,BIFURCATION,PULSATIONS,CIRCULATION,SIMULATION,Reflection,Ductus venosus,Wave propagation,VELOCITY,LIVER,BLOOD-FLOW}},
  language     = {{eng}},
  number       = {{6}},
  pages        = {{509--517}},
  title        = {{An assessment of ductus venosus tapering and wave transmission from the fetal heart}},
  url          = {{http://doi.org/10.1007/s10237-009-0155-4}},
  volume       = {{8}},
  year         = {{2009}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: