Advanced search
1 file | 764.10 KB Add to list
Author
Organization
Abstract
The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time.
Keywords
Detector alignment and calibration methods (lasers, sources, particle-beams), Performance of High Energy Physics Detectors, Resistive-plate chambers

Downloads

  • Reyes-Almanza 2019 J. Inst. 14 C09046.pdf
    • full text (Published version)
    • |
    • open access
    • |
    • PDF
    • |
    • 764.10 KB

Citation

Please use this url to cite or link to this publication:

MLA
Reyes-Almanza, R., et al. “High Voltage Calibration Method for the CMS RPC Detector.” JOURNAL OF INSTRUMENTATION, vol. 14, no. 9, 2019, doi:10.1088/1748-0221/14/09/C09046.
APA
Reyes-Almanza, R., Dimitrov, A., Fagot, A., Gul, M., Roskas, C., Tytgat, M., … Crotty, I. (2019). High voltage calibration method for the CMS RPC detector. JOURNAL OF INSTRUMENTATION, 14(9). https://doi.org/10.1088/1748-0221/14/09/C09046
Chicago author-date
Reyes-Almanza, R., A. Dimitrov, A. Fagot, M. Gul, C. Roskas, M. Tytgat, N. Zaganidis, et al. 2019. “High Voltage Calibration Method for the CMS RPC Detector.” JOURNAL OF INSTRUMENTATION 14 (9). https://doi.org/10.1088/1748-0221/14/09/C09046.
Chicago author-date (all authors)
Reyes-Almanza, R., A. Dimitrov, A. Fagot, M. Gul, C. Roskas, M. Tytgat, N. Zaganidis, S. Fonseca De Souza, A. Santoro, F. Torres Da Silva De Araujo, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, L. Litov, B. Pavlov, P. Petkov, A. Petrov, S. J. Qian, D. Han, W. Yi, C. Avila, A. Cabrera, C. Carrillo, M. Segura, S. Aly, Y. Assran, A. Mahrous, A. Mohamed, C. Combaret, M. Gouzevitch, G. Grenier, F. Lagarde, I. B. Laktineh, H. Mathez, L. Mirabito, K. Shchablo, I. Bagaturia, D. Lomidze, I. Lomidze, L. M. Pant, V. Bhatnagar, R. Gupta, R. Kumari, M. Lohan, J. B. Singh, V. Amoozegar, B. Boghrati, H. Ghasemy, S. Malmir, M. Mohammadi Najafabadi, M. Abbrescia, A. Gelmi, G. Iaselli, S. Lezki, G. Pugliese, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, S. Buontempo, A. Crescenzo, G. Galati, F. Fienga, I. Orso, L. Lista, S. Meola, P. Paolucci, E. Voevodina, A. Braghieri, P. Montagna, M. Ressegotti, C. Riccardi, P. Salvini, P. Vitulo, S. W. Cho, S. Y. Choi, B. Hong, K. S. Lee, J. H. Lim, S. K. Park, J. Goh, T. J. Kim, S. Carrillo Moreno, O. Miguel Colin, F. Vazquez Valencia, S. Carpinteyro Bernardino, J. Eysermans, I. Pedraza, C. Uribe Estrada, M. C. Duran-Osuna, M. Ramirez-Garcia, G. Ramirez-Sanchez, A. Sanchez-Hernandez, R. I. Rabadan-Trejo, H. Castilla-Valdez, A. Radi, H. Hoorani, S. Muhammad, M. A. Shah, and I. Crotty. 2019. “High Voltage Calibration Method for the CMS RPC Detector.” JOURNAL OF INSTRUMENTATION 14 (9). doi:10.1088/1748-0221/14/09/C09046.
Vancouver
1.
Reyes-Almanza R, Dimitrov A, Fagot A, Gul M, Roskas C, Tytgat M, et al. High voltage calibration method for the CMS RPC detector. JOURNAL OF INSTRUMENTATION. 2019;14(9).
IEEE
[1]
R. Reyes-Almanza et al., “High voltage calibration method for the CMS RPC detector,” JOURNAL OF INSTRUMENTATION, vol. 14, no. 9, 2019.
@article{8666102,
  abstract     = {The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time.},
  articleno    = {C09046},
  author       = {Reyes-Almanza, R. and Dimitrov, A. and Fagot, A. and Gul, M. and Roskas, C. and Tytgat, M. and Zaganidis, N. and Fonseca De Souza, S. and Santoro, A. and Da Silva De Araujo, F. Torres and Aleksandrov, A. and Hadjiiska, R. and Iaydjiev, P. and Rodozov, M. and Shopova, M. and Sultanov, G. and Litov, L. and Pavlov, B. and Petkov, P. and Petrov, A. and Qian, S. J. and Han, D. and Yi, W. and Avila, C. and Cabrera, A. and Carrillo, C. and Segura, M. and Aly, S. and Assran, Y. and Mahrous, A. and Mohamed, A. and Combaret, C. and Gouzevitch, M. and Grenier, G. and Lagarde, F. and Laktineh, I. B. and Mathez, H. and Mirabito, L. and Shchablo, K. and Bagaturia, I. and Lomidze, D. and Lomidze, I. and Pant, L. M. and Bhatnagar, V. and Gupta, R. and Kumari, R. and Lohan, M. and Singh, J. B. and Amoozegar, V. and Boghrati, B. and Ghasemy, H. and Malmir, S. and Najafabadi, M. Mohammadi and Abbrescia, M. and Gelmi, A. and Iaselli, G. and Lezki, S. and Pugliese, G. and Benussi, L. and Bianco, S. and Piccolo, D. and Primavera, F. and Buontempo, S. and Crescenzo, A. and Galati, G. and Fienga, F. and Orso, I. and Lista, L. and Meola, S. and Paolucci, P. and Voevodina, E. and Braghieri, A. and Montagna, P. and Ressegotti, M. and Riccardi, C. and Salvini, P. and Vitulo, P. and Cho, S. W. and Choi, S. Y. and Hong, B. and Lee, K. S. and Lim, J. H. and Park, S. K. and Goh, J. and Kim, T. J. and Carrillo Moreno, S. and Miguel Colin, O. and Vazquez Valencia, F. and Carpinteyro Bernardino, S. and Eysermans, J. and Pedraza, I. and Uribe Estrada, C. and Duran-Osuna, M. C. and Ramirez-Garcia, M. and Ramirez-Sanchez, G. and Sanchez-Hernandez, A. and Rabadan-Trejo, R. I. and Castilla-Valdez, H. and Radi, A. and Hoorani, H. and Muhammad, S. and Shah, M. A. and Crotty, I.},
  issn         = {1748-0221},
  journal      = {JOURNAL OF INSTRUMENTATION},
  keywords     = {Detector alignment and calibration methods (lasers,sources,particle-beams),Performance of High Energy Physics Detectors,Resistive-plate chambers},
  language     = {eng},
  location     = {Puerto Vallarta, MEXICO},
  number       = {9},
  pages        = {7},
  title        = {High voltage calibration method for the CMS RPC detector},
  url          = {http://dx.doi.org/10.1088/1748-0221/14/09/C09046},
  volume       = {14},
  year         = {2019},
}

Altmetric
View in Altmetric
Web of Science
Times cited: