Advanced search
1 file | 2.31 MB Add to list

R&D of a real-size mosaic MRPC within the framework of the CMS muon upgrade

Author
Organization
Abstract
Based on previous experience and attempt, a real-size mosaic Multi-gap Resistive Plate Chamber (MRPC) has been developed within the framework of the CMS muon upgrade efforts. The chamber is a 5-gap with plates made each of 6 pieces of low resistive glass. Cosmic ray test at CERN 904 shows that its efficiency can reach above 95% with a gas mixture of 90% C2H2F4, 5% i-C4H10 and 5% SF6. The chamber was also tested with CMS dry gas(95.2% C2H2F4, 4.5% i-C4H10, 0.3% SF6) at the CERN Gamma Irradiation Facility (GIF++). Efficiency results calculated by a simple tracking method show that the good performance is maintained at rates up to 10 kHz/cm(2).
Keywords
SF6, Gaseous detectors, Instrumentation and methods for time-of-flight (TOF), spectroscopy, Resistive-plate chambers

Downloads

  • (...).pdf
    • full text (Published version)
    • |
    • UGent only
    • |
    • PDF
    • |
    • 2.31 MB

Citation

Please use this url to cite or link to this publication:

MLA
Yu, Y., et al. “R&D of a Real-Size Mosaic MRPC within the Framework of the CMS Muon Upgrade.” JOURNAL OF INSTRUMENTATION, vol. 14, Iop Publishing Ltd, 2019, doi:10.1088/1748-0221/14/10/C10042.
APA
Yu, Y., Han, D., Wang, Y., Guo, B., Lyu, P., Chen, X., … Vaitkus, J. (2019). R&D of a real-size mosaic MRPC within the framework of the CMS muon upgrade. JOURNAL OF INSTRUMENTATION, 14. https://doi.org/10.1088/1748-0221/14/10/C10042
Chicago author-date
Yu, Y., D. Han, Y. Wang, B. Guo, P. Lyu, X. Chen, C. Shen, et al. 2019. “R&D of a Real-Size Mosaic MRPC within the Framework of the CMS Muon Upgrade.” JOURNAL OF INSTRUMENTATION 14. https://doi.org/10.1088/1748-0221/14/10/C10042.
Chicago author-date (all authors)
Yu, Y., D. Han, Y. Wang, B. Guo, P. Lyu, X. Chen, C. Shen, F. Wang, Y. Li, Anna Cimmino, Shannon Rebecca Crucy, Alexis Fagot, Muhammad Gul, Alberto Andres Ocampo Rios, Michael Tytgat, Nikolaos Zaganidis, S. Aly, Y. Assran, A. Radi, A. Sayed, G. Singh, M. Abbrescia, G. Iaselli, M. Maggi, G. Pugliese, P. Verwilligen, W. Van Doninck, S. Colafranceschi, A. Sharma, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, V Bhatnagar, R. Kumari, A. Mehta, J. Singh, A. Ahmad, W. Ahmed, I Asghar, M., I. M. Awan, R. Hoorani, S. Muhammad, H. Shahzad, M. A. Shah, S. W. Cho, S. Y. Choi, B. Hong, M. H. Kang, K. S. Lee, J. H. Lim, S. K. Park, M. S. Kim, S. Carpinteyro Bernardino, I Pedraza, C. Uribe Estrada, S. Carrillo Moreno, F. Vazquez Valencia, L. M. Pant, S. Buontempo, N. Cavallo, M. Esposito, F. Fabozzi, G. Lanza, I Orso, L. Lista, S. Meola, M. Merola, P. Paolucci, F. Thyssen, A. Braghieri, A. Magnani, P. Montagna, C. Riccardi, P. Salvini, I Vai, P. Vitulo, Y. Ban, S. J. Qian, M. Choi, Y. Choi, J. Goh, D. Kim, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, S. Stoykova, G. Sultanov, M. Vutova, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, I Bagaturia, D. Lomidze, C. Avila, A. Cabrera, J. C. Sanabria, I Crotty, and J. Vaitkus. 2019. “R&D of a Real-Size Mosaic MRPC within the Framework of the CMS Muon Upgrade.” JOURNAL OF INSTRUMENTATION 14. doi:10.1088/1748-0221/14/10/C10042.
Vancouver
1.
Yu Y, Han D, Wang Y, Guo B, Lyu P, Chen X, et al. R&D of a real-size mosaic MRPC within the framework of the CMS muon upgrade. JOURNAL OF INSTRUMENTATION. 2019;14.
IEEE
[1]
Y. Yu et al., “R&D of a real-size mosaic MRPC within the framework of the CMS muon upgrade,” JOURNAL OF INSTRUMENTATION, vol. 14, 2019.
@article{8666097,
  abstract     = {{Based on previous experience and attempt, a real-size mosaic Multi-gap Resistive Plate Chamber (MRPC) has been developed within the framework of the CMS muon upgrade efforts. The chamber is a 5-gap with plates made each of 6 pieces of low resistive glass. Cosmic ray test at CERN 904 shows that its efficiency can reach above 95% with a gas mixture of 90% C2H2F4, 5% i-C4H10 and 5% SF6. The chamber was also tested with CMS dry gas(95.2% C2H2F4, 4.5% i-C4H10, 0.3% SF6) at the CERN Gamma Irradiation Facility (GIF++). Efficiency results calculated by a simple tracking method show that the good performance is maintained at rates up to 10 kHz/cm(2).}},
  articleno    = {{C10042}},
  author       = {{Yu, Y. and Han, D. and Wang, Y. and Guo, B. and Lyu, P. and Chen, X. and Shen, C. and Wang, F. and Li, Y. and Cimmino, Anna and Crucy, Shannon Rebecca and Fagot, Alexis and Gul, Muhammad and Ocampo Rios, Alberto Andres and Tytgat, Michael and Zaganidis, Nikolaos and Aly, S. and Assran, Y. and Radi, A. and Sayed, A. and Singh, G. and Abbrescia, M. and Iaselli, G. and Maggi, M. and Pugliese, G. and Verwilligen, P. and Van Doninck, W. and Colafranceschi, S. and Sharma, A. and Benussi, L. and Bianco, S. and Piccolo, D. and Primavera, F. and Bhatnagar, V and Kumari, R. and Mehta, A. and Singh, J. and Ahmad, A. and Ahmed, W. and Asghar, M., I and Awan, I. M. and Hoorani, R. and Muhammad, S. and Shahzad, H. and Shah, M. A. and Cho, S. W. and Choi, S. Y. and Hong, B. and Kang, M. H. and Lee, K. S. and Lim, J. H. and Park, S. K. and Kim, M. S. and Carpinteyro Bernardino, S. and Pedraza, I and Uribe Estrada, C. and Carrillo Moreno, S. and Vazquez Valencia, F. and Pant, L. M. and Buontempo, S. and Cavallo, N. and Esposito, M. and Fabozzi, F. and Lanza, G. and Orso, I and Lista, L. and Meola, S. and Merola, M. and Paolucci, P. and Thyssen, F. and Braghieri, A. and Magnani, A. and Montagna, P. and Riccardi, C. and Salvini, P. and Vai, I and Vitulo, P. and Ban, Y. and Qian, S. J. and Choi, M. and Choi, Y. and Goh, J. and Kim, D. and Aleksandrov, A. and Hadjiiska, R. and Iaydjiev, P. and Rodozov, M. and Stoykova, S. and Sultanov, G. and Vutova, M. and Dimitrov, A. and Litov, L. and Pavlov, B. and Petkov, P. and Bagaturia, I and Lomidze, D. and Avila, C. and Cabrera, A. and Sanabria, J. C. and Crotty, I and Vaitkus, J.}},
  issn         = {{1748-0221}},
  journal      = {{JOURNAL OF INSTRUMENTATION}},
  keywords     = {{SF6,Gaseous detectors,Instrumentation and methods for time-of-flight (TOF),spectroscopy,Resistive-plate chambers}},
  language     = {{eng}},
  location     = {{Puerto Vallarta, Mexico}},
  pages        = {{9}},
  publisher    = {{Iop Publishing Ltd}},
  title        = {{R&D of a real-size mosaic MRPC within the framework of the CMS muon upgrade}},
  url          = {{http://doi.org/10.1088/1748-0221/14/10/C10042}},
  volume       = {{14}},
  year         = {{2019}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: