Advanced search
Add to list

Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla

(2005) MAGNETIC RESONANCE IN MEDICINE. 54(6). p.1465-1472
Author
Organization
Abstract
The blood oxygen level dependent (BOLD) response, as measured with fMRI, offers good spatial resolution compared to other non-invasive neuroimaging methods. The use of a spin echo technique rather than the conventional gradient echo technique may further improve the resolution by refocusing static dephasing effects around the larger vessels, so sensitizing the signal to the microvasculature. In this work the width of the point spread function (PSF) of the BOLD response at a field strength of 3 Tesla is compared for these two approaches. A double echo EPI pulse sequence with simultaneous collection of gradient echo and spin echo signal allows a direct comparison of the techniques. Rotating multiple-wedge stimuli of different spatial frequencies are used to estimate the width of the BOLD response. Waves of activation are created on the surface of the visual cortex, which begin to overlap as the wedge separation decreases. The modulation of the BOLD response decreases with increasing spatial frequency in a manner dependent on its width. The spin echo response shows a 13% reduction in the width of the PSF, but at a cost of at least 3-fold reduction in contrast to noise ratio.
Keywords
HUMAN VISUAL-CORTEX, HUMAN BRAIN, FUNCTIONAL MRI, 1.5 T, FMRI, CONTRAST, SUPPRESSION, SIGNAL, MOTOR, TIME, BOLD, fMRI, spatial resolution, spin echo

Citation

Please use this url to cite or link to this publication:

MLA
Parkes, LM, et al. “Quantifying the Spatial Resolution of the Gradient Echo and Spin Echo BOLD Response at 3 Tesla.” MAGNETIC RESONANCE IN MEDICINE, vol. 54, no. 6, 2005, pp. 1465–72.
APA
Parkes, L., Schwarzbach, J., Bouts, A., Deckers, R., Pullens, P., Kerskens, C., & Norris, D. (2005). Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla. MAGNETIC RESONANCE IN MEDICINE, 54(6), 1465–1472.
Chicago author-date
Parkes, LM, JV Schwarzbach, AA Bouts, RHR Deckers, Pim Pullens, CM Kerskens, and DG Norris. 2005. “Quantifying the Spatial Resolution of the Gradient Echo and Spin Echo BOLD Response at 3 Tesla.” MAGNETIC RESONANCE IN MEDICINE 54 (6): 1465–72.
Chicago author-date (all authors)
Parkes, LM, JV Schwarzbach, AA Bouts, RHR Deckers, Pim Pullens, CM Kerskens, and DG Norris. 2005. “Quantifying the Spatial Resolution of the Gradient Echo and Spin Echo BOLD Response at 3 Tesla.” MAGNETIC RESONANCE IN MEDICINE 54 (6): 1465–1472.
Vancouver
1.
Parkes L, Schwarzbach J, Bouts A, Deckers R, Pullens P, Kerskens C, et al. Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla. MAGNETIC RESONANCE IN MEDICINE. 2005;54(6):1465–72.
IEEE
[1]
L. Parkes et al., “Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla,” MAGNETIC RESONANCE IN MEDICINE, vol. 54, no. 6, pp. 1465–1472, 2005.
@article{8632136,
  abstract     = {{The blood oxygen level dependent (BOLD) response, as measured with fMRI, offers good spatial resolution compared to other non-invasive neuroimaging methods. The use of a spin echo technique rather than the conventional gradient echo technique may further improve the resolution by refocusing static dephasing effects around the larger vessels, so sensitizing the signal to the microvasculature. In this work the width of the point spread function (PSF) of the BOLD response at a field strength of 3 Tesla is compared for these two approaches. A double echo EPI pulse sequence with simultaneous collection of gradient echo and spin echo signal allows a direct comparison of the techniques. Rotating multiple-wedge stimuli of different spatial frequencies are used to estimate the width of the BOLD response. Waves of activation are created on the surface of the visual cortex, which begin to overlap as the wedge separation decreases. The modulation of the BOLD response decreases with increasing spatial frequency in a manner dependent on its width. The spin echo response shows a 13% reduction in the width of the PSF, but at a cost of at least 3-fold reduction in contrast to noise ratio.}},
  author       = {{Parkes, LM and Schwarzbach, JV and Bouts, AA and Deckers, RHR and Pullens, Pim and Kerskens, CM and Norris, DG}},
  issn         = {{0740-3194}},
  journal      = {{MAGNETIC RESONANCE IN MEDICINE}},
  keywords     = {{HUMAN VISUAL-CORTEX,HUMAN BRAIN,FUNCTIONAL MRI,1.5 T,FMRI,CONTRAST,SUPPRESSION,SIGNAL,MOTOR,TIME,BOLD,fMRI,spatial resolution,spin echo}},
  language     = {{eng}},
  number       = {{6}},
  pages        = {{1465--1472}},
  title        = {{Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla}},
  url          = {{http://dx.doi.org/10.1002/mrm.20712}},
  volume       = {{54}},
  year         = {{2005}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: