Advanced search
1 file | 439.95 KB

Estimating the reliability of low-abundant signals and limited replicate measurements through MS2 peak area in SWATH

(2018) PROTEOMICS. 18(24).
Author
Organization
Abstract
Sequential windows acquisition of all theoretical fragment ions mass spectrometry (SWATH-MS) provides large-scale protein quantification with high accuracy and selectivity. Nevertheless, reliable quantification of low-abundant signals in complex samples remains challenging, as recently illustrated in a multicenter benchmark study of different label-free software tools. Here, the SWATH Replicates Analysis 2.0 template from Sciex is used to highlight that the relationship between the MS2 peak area and the variability can be described by a function. This functional relationship appears to be largely insensitive to variation in samples or acquisition conditions, suggesting a device-intrinsic property. By using a power regression, it is shown that the MS2 peak area can be used to predict the quantification repeatability without relying on replicate injections, thus contributing to high-throughput confident quantification of low-abundant signals with SWATH-MS.
Keywords
low-abundant signals, MS2 peak area, repeatability, sequential windows acquisition of all theoretical fragment ions mass spectrometry, DATA-INDEPENDENT ACQUISITION, PROTEOME, DYNAMICS, PEPTIDE

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 439.95 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Limonier, Franck, Sander Willems, Geneviève Waeterloos, Myriam Sneyers, Maarten Dhaenens, and Dieter Deforce. 2018. “Estimating the Reliability of Low-abundant Signals and Limited Replicate Measurements Through MS2 Peak Area in SWATH.” Proteomics 18 (24).
APA
Limonier, F., Willems, S., Waeterloos, G., Sneyers, M., Dhaenens, M., & Deforce, D. (2018). Estimating the reliability of low-abundant signals and limited replicate measurements through MS2 peak area in SWATH. PROTEOMICS, 18(24).
Vancouver
1.
Limonier F, Willems S, Waeterloos G, Sneyers M, Dhaenens M, Deforce D. Estimating the reliability of low-abundant signals and limited replicate measurements through MS2 peak area in SWATH. PROTEOMICS. 2018;18(24).
MLA
Limonier, Franck et al. “Estimating the Reliability of Low-abundant Signals and Limited Replicate Measurements Through MS2 Peak Area in SWATH.” PROTEOMICS 18.24 (2018): n. pag. Print.
@article{8580466,
  abstract     = {Sequential windows acquisition of all theoretical fragment ions mass spectrometry (SWATH-MS) provides large-scale protein quantification with high accuracy and selectivity. Nevertheless, reliable quantification of low-abundant signals in complex samples remains challenging, as recently illustrated in a multicenter benchmark study of different label-free software tools. Here, the SWATH Replicates Analysis 2.0 template from Sciex is used to highlight that the relationship between the MS2 peak area and the variability can be described by a function. This functional relationship appears to be largely insensitive to variation in samples or acquisition conditions, suggesting a device-intrinsic property. By using a power regression, it is shown that the MS2 peak area can be used to predict the quantification repeatability without relying on replicate injections, thus contributing to high-throughput confident quantification of low-abundant signals with SWATH-MS.},
  articleno    = {1800186},
  author       = {Limonier, Franck and Willems, Sander and Waeterloos, Genevi{\`e}ve and Sneyers, Myriam and Dhaenens, Maarten and Deforce, Dieter},
  issn         = {1615-9853},
  journal      = {PROTEOMICS},
  language     = {eng},
  number       = {24},
  pages        = {5},
  title        = {Estimating the reliability of low-abundant signals and limited replicate measurements through MS2 peak area in SWATH},
  url          = {http://dx.doi.org/10.1002/pmic.201800186},
  volume       = {18},
  year         = {2018},
}

Altmetric
View in Altmetric
Web of Science
Times cited: