Ghent University Academic Bibliography

Advanced

The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade

W. Ahmed, D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Aki, D. Acosta, A. Ahmad, W. Ahmed, A. Aleksandrov, et al. (2017) JOURNAL OF INSTRUMENTATION. 12.
abstract
The CMS experiment at LHC will upgrade its forward muon spectrometer by incorporating Triple-GEM detectors. This upgrade referred to as GEM Endcap (GE1/1), consists of adding two back-to-back Triple-GEM detectors in front of the existing Cathode Strip Chambers (CSC) in the innermost ring of the endcap muon spectrometer. Before the full installation of 144 detectors in 2019-2020, CMS will first install ten single chamber prototypes during the early 2017. This pre-installation is referred as the slice test. These ten detectors will be read-out by VFAT2 chips [1]. On-detector there is also a FPGA mezzanine card which sends VFAT2 data optically to the mu TCA back-end electronics. The correct and safe operation of the GEM system requires a sophisticated and powerful online Detector Control System, able to monitor and control many heterogeneous hardware devices. The DCS system developed for the slice test has been tested with CMS Triple-GEM detectors in the laboratory. In this paper we describe the newly developed DCS system and present the first results obtained in the GEM assembly and quality assurance laboratory.
Please use this url to cite or link to this publication:
author
year
type
journalArticle (original)
publication status
published
journal title
JOURNAL OF INSTRUMENTATION
volume
12
article number
P02003
Web of Science type
J
Web of Science id
000397826200003
ISSN
1748-0221
DOI
10.1088/1748-0221/12/02/P02003
UGent publication?
yes
classification
A1
id
8568652
handle
http://hdl.handle.net/1854/LU-8568652
date created
2018-07-06 14:58:11
date last changed
2018-07-09 08:32:17
@article{8568652,
  abstract     = {The CMS experiment at LHC will upgrade its forward muon spectrometer by incorporating Triple-GEM detectors. This upgrade referred to as GEM Endcap (GE1/1), consists of adding two back-to-back Triple-GEM detectors in front of the existing Cathode Strip Chambers (CSC) in the innermost ring of the endcap muon spectrometer. Before the full installation of 144 detectors in 2019-2020, CMS will first install ten single chamber prototypes during the early 2017. This pre-installation is referred as the slice test. These ten detectors will be read-out by VFAT2 chips [1]. On-detector there is also a FPGA mezzanine card which sends VFAT2 data optically to the mu TCA back-end electronics. The correct and safe operation of the GEM system requires a sophisticated and powerful online Detector Control System, able to monitor and control many heterogeneous hardware devices. The DCS system developed for the slice test has been tested with CMS Triple-GEM detectors in the laboratory. In this paper we describe the newly developed DCS system and present the first results obtained in the GEM assembly and quality assurance laboratory.},
  articleno    = {P02003},
  author       = {Ahmed, W. and Abbaneo, D. and Abbas, M. and Abbrescia, M. and Abdelalim, A. A. and Aki, M. Abi and Acosta, D. and Ahmad, A. and Ahmed, W. and Aleksandrov, A. and Aly, R. and Altieri, P. and Asawatangtrakuldee, C. and Aspe, P. and Assran, Y. and Awan, I. and Bally, S. and Ban, Y. and Banerjee, S. and Barashko, V. and Barria, P. and Bencze, G. and Beni, N. and Benussi, L. and Bhopatkar, V. and Bianco, S. and Bos, J. and Bouhali, O. and Holme, O. and Braghieri, A. and Braibant, S. and Buontempo, S. and Khan, S. A. and Calabria, C. and Caponero, M. and Caputo, C. and Cassese, F. and Castaneda, A. and Cauwenbergh, S. and Cavallo, F. R. and Celik, A. and Choi, M. and Choi, S. and Christiansen, J. and Cimmino, Anna and Colafranceschi, S. and Colaleo, A. and Garcia, A. Conde and Czellar, S. and Dabrowski, M. M. and De Lentdecker, G. and De Oliveira, R. and De Robertis, G. and Dildick, Sven and Dorney, B. and Elmetenawee, W. and Endroczi, G. and Errico, F. and Fenyvesi, A. and Ferry, S. and Furic, I. and Giacomelli, P. and Gilmore, J. and Golovtsov, V. and Guiducci, L. and Guilloux, F. and Gutierrez, A. and Hadjiiska, R. M. and Hassan, A. and Hauser, J. and Hoepfner, K. and Hohlmann, M. and Hoorani, H. and Shah, A. H. and Laydjiev, P. and Jeng, Y. G. and Kamon, T. and Karchin, P. and Korytov, A. and Krutelyov, S. and Kumar, A. and Kim, H. and Lenzi, T. and Litov, L. and Loddo, F. and Madorsky, A. and Maerschalk, T. and Maggi, M. and Magnani, A. and Mal, P. K. and Mandal, K. and Marchioro, A. and Marinov, Andrey and Majumdar, N. and Merlin, J. A. and Mitselmakher, G. and Mohanty, A. K. and Mohapatra, A. and Molnar, J. and Muhammad, S. and Mukhopadhyay, S. and Naimuddin, M. and Nuzzo, S. and Oliveri, E. and Pant, L. M. and Paolucci, P. and Park, I. and Passeggio, G. and Pavlov, B. and Philipps, B. and Piccolo, D. and Postema, H. and Baranac, A. Puig and Radi, A. and Radogna, R. and Raffone, G. and Ranieri, A. and Rashevski, G. and Riccardi, C. and Rodozov, M. and Rodrigues, A. and Ropelewski, L. and RoyChowdhury, S. and Ryu, G. and Ryu, M. S. and Safonov, A. and Salva, Sinem and Saviano, G. and Sharma, A. and Sharma, R. and Shopova, M. and Sturdy, J. and Sultanov, G. and Swain, S. K. and Szillasi, Z. and Talvitie, J. and Tatarinov, A. and Tuuva, T. and Tytgat, Michael and Vai, I. and Van Stenis, M. and Venditti, R. and Verhagen, E. and Verwilligen, Piet and Vitulo, P. and Volkov, S. and Vorobyev, A. and Wang, D. and Wang, M. and Yang, U. and Yang, Y. and Yonamine, R. and Zaganidis, Nikolaos and Zenoni, F. and Zhang, A.},
  issn         = {1748-0221},
  journal      = {JOURNAL OF INSTRUMENTATION},
  title        = {The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade},
  url          = {http://dx.doi.org/10.1088/1748-0221/12/02/P02003},
  volume       = {12},
  year         = {2017},
}

Chicago
Ahmed, W., D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Aki, D. Acosta, et al. 2017. “The Triple GEM Detector Control System for CMS Forward Muon Spectrometer Upgrade.” Journal of Instrumentation 12.
APA
Ahmed, W., Abbaneo, D., Abbas, M., Abbrescia, M., Abdelalim, A. A., Aki, M. A., Acosta, D., et al. (2017). The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade. JOURNAL OF INSTRUMENTATION, 12.
Vancouver
1.
Ahmed W, Abbaneo D, Abbas M, Abbrescia M, Abdelalim AA, Aki MA, et al. The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade. JOURNAL OF INSTRUMENTATION. 2017;12.
MLA
Ahmed, W., D. Abbaneo, M. Abbas, et al. “The Triple GEM Detector Control System for CMS Forward Muon Spectrometer Upgrade.” JOURNAL OF INSTRUMENTATION 12 (2017): n. pag. Print.