Imaging artifacts in continuous scanning 2D LA-ICPMS imaging due to nonsynchronization issues

(2018) ANALYTICAL CHEMISTRY. 90(4). p.2896-2901
Author
Organization
Abstract
Pulsed laser ablation (LA) devices in laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) imaging have become very advanced, delivering laser pulses with high temporal accuracy and stable energy density. However, unintentional imaging artifacts may be generated in 2D element maps when the LA repetition rate and the data acquisition parameters of ICPMS instruments with a sequential mass spectrometer (i.e., quadrupole filter or sector-field mass spectrometer) are desynchronized. This may potentially lead to interference patterns, visible as ripples in elemental images, and thus, compromised image quality. This paper describes the background of aliasing in continuous scanning mode through simulation experiments and ways to modulate the effect. The existence of this image degradation source is demonstrated experimentally via real-life imaging of a homogeneous glass standard.
Keywords
PLASMA-MASS SPECTROMETRY, LASER-ABLATION, MODELING APPROACH, RESOLUTION, METRICS, DESIGN, CELLS

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 2.75 MB

Citation

Please use this url to cite or link to this publication:

Chicago
van Elteren, Johannes T, Vid S Šelih, Martin Šala, Stijn Van Malderen, and Frank Vanhaecke. 2018. “Imaging Artifacts in Continuous Scanning 2D LA-ICPMS Imaging Due to Nonsynchronization Issues.” Analytical Chemistry 90 (4): 2896–2901.
APA
van Elteren, Johannes T, Šelih, V. S., Šala, M., Van Malderen, S., & Vanhaecke, F. (2018). Imaging artifacts in continuous scanning 2D LA-ICPMS imaging due to nonsynchronization issues. ANALYTICAL CHEMISTRY, 90(4), 2896–2901.
Vancouver
1.
van Elteren JT, Šelih VS, Šala M, Van Malderen S, Vanhaecke F. Imaging artifacts in continuous scanning 2D LA-ICPMS imaging due to nonsynchronization issues. ANALYTICAL CHEMISTRY. 2018;90(4):2896–901.
MLA
van Elteren, Johannes T, Vid S Šelih, Martin Šala, et al. “Imaging Artifacts in Continuous Scanning 2D LA-ICPMS Imaging Due to Nonsynchronization Issues.” ANALYTICAL CHEMISTRY 90.4 (2018): 2896–2901. Print.
@article{8562895,
  abstract     = {Pulsed laser ablation (LA) devices in laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) imaging have become very advanced, delivering laser pulses with high temporal accuracy and stable energy density. However, unintentional imaging artifacts may be generated in 2D element maps when the LA repetition rate and the data acquisition parameters of ICPMS instruments with a sequential mass spectrometer (i.e., quadrupole filter or sector-field mass spectrometer) are desynchronized. This may potentially lead to interference patterns, visible as ripples in elemental images, and thus, compromised image quality. This paper describes the background of aliasing in continuous scanning mode through simulation experiments and ways to modulate the effect. The existence of this image degradation source is demonstrated experimentally via real-life imaging of a homogeneous glass standard.},
  author       = {van Elteren, Johannes T and \v{S}elih, Vid S and \v{S}ala, Martin and Van Malderen, Stijn and Vanhaecke, Frank},
  issn         = {0003-2700},
  journal      = {ANALYTICAL CHEMISTRY},
  keyword      = {PLASMA-MASS SPECTROMETRY,LASER-ABLATION,MODELING APPROACH,RESOLUTION,METRICS,DESIGN,CELLS},
  language     = {eng},
  number       = {4},
  pages        = {2896--2901},
  title        = {Imaging artifacts in continuous scanning 2D LA-ICPMS imaging due to nonsynchronization issues},
  url          = {http://dx.doi.org/10.1021/acs.analchem.7b05134},
  volume       = {90},
  year         = {2018},
}

Altmetric
View in Altmetric
Web of Science
Times cited: