Advanced search
1 file | 309.68 KB

Variability of cut-off values for the detection of lupus anticoagulants : results of an international multicenter multiplatform study

Author
Organization
Keywords
activated partial thromboplastin time, antiphospholipid syndrome, dilute Russell viper venom test, screening, standardization, ANTIPHOSPHOLIPID SYNDROME, TIME, THROMBOPHILIA, LABORATORIES, PATHOLOGISTS, PERFORMANCE, DIAGNOSIS, COLLEGE, PROGRAM, UPDATE

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 309.68 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Tripodi, A, V Chantarangkul, M Cini, Katrien Devreese, JS Dlott, R Giacomello, E Gray, et al. 2017. “Variability of Cut-off Values for the Detection of Lupus Anticoagulants : Results of an International Multicenter Multiplatform Study.” Journal of Thrombosis and Haemostasis 15 (6): 1180–1190.
APA
Tripodi, A., Chantarangkul, V., Cini, M., Devreese, K., Dlott, J., Giacomello, R., Gray, E., et al. (2017). Variability of cut-off values for the detection of lupus anticoagulants : results of an international multicenter multiplatform study. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 15(6), 1180–1190.
Vancouver
1.
Tripodi A, Chantarangkul V, Cini M, Devreese K, Dlott J, Giacomello R, et al. Variability of cut-off values for the detection of lupus anticoagulants : results of an international multicenter multiplatform study. JOURNAL OF THROMBOSIS AND HAEMOSTASIS. 2017;15(6):1180–90.
MLA
Tripodi, A, V Chantarangkul, M Cini, et al. “Variability of Cut-off Values for the Detection of Lupus Anticoagulants : Results of an International Multicenter Multiplatform Study.” JOURNAL OF THROMBOSIS AND HAEMOSTASIS 15.6 (2017): 1180–1190. Print.
@article{8548954,
  author       = {Tripodi, A and Chantarangkul, V and Cini, M and Devreese, Katrien and Dlott, JS and Giacomello, R and Gray, E and Legnani, C and Martinuzzo, ME and Pradella, P and Siegemund, A and Subramanian, S and Suchon, P and Testa, S},
  issn         = {1538-7933},
  journal      = {JOURNAL OF THROMBOSIS AND HAEMOSTASIS},
  keywords     = {activated partial thromboplastin time,antiphospholipid syndrome,dilute Russell viper venom test,screening,standardization,ANTIPHOSPHOLIPID SYNDROME,TIME,THROMBOPHILIA,LABORATORIES,PATHOLOGISTS,PERFORMANCE,DIAGNOSIS,COLLEGE,PROGRAM,UPDATE},
  language     = {eng},
  number       = {6},
  pages        = {1180--1190},
  title        = {Variability of cut-off values for the detection of lupus anticoagulants : results of an international multicenter multiplatform study},
  url          = {http://dx.doi.org/10.1111/jth.13678},
  volume       = {15},
  year         = {2017},
}

Altmetric
View in Altmetric
Web of Science
Times cited: