Development and validation of the Vietnamese primary care assessment tool

(2018) PLOS ONE. 13(1).
Author
Organization
Abstract
Objective : To adapt the consumer version of the Primary Care Assessment Tool (PCAT) for Vietnam and determine its internal consistency and validity. Design : A quantitative cross sectional study. Setting : 56 communes in 3 representative provinces of central Vietnam. Participants : Total of 3289 people who used health care services at health facility at least once over the past two years. Results : The Vietnamese adult expanded consumer version of the PCAT (VN PCAT-AE) is an instrument for evaluation of primary care in Vietnam with 70 items comprising six scales representing four core primary care domains, and three additional scales representing three derivative domains. Sixteen other items from the original tool were not included in the final instrument, due to problems with missing values, floor or ceiling effects, and item-total correlations. All the retained scales have a Cronbach’s alpha above 0.70 except for the subscale of Family Centeredness. Conclusions : The VN PCAT-AE demonstrates adequate internal consistency and validity to be used as an effective tool for measuring the quality of primary care in Vietnam from the consumer perspective. Additional work in the future to optimize valid measurement in all domains consistent with the original version of the tool may be helpful as the primary care system in Vietnam further develops.
Keywords
Primary Healthcare, PCAT, assessment, Vietnam, PRIMARY-HEALTH-CARE, QUALITY, COUNTRIES, OUTCOMES, SYSTEMS, VERSION

Downloads

  • journal.pone.0191181.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 1.69 MB

Citation

Please use this url to cite or link to this publication:

MLA
Nguyễn Thị, Hòa, et al. “Development and Validation of the Vietnamese Primary Care Assessment Tool.” PLOS ONE, vol. 13, no. 1, 2018, doi:10.1371/journal.pone.0191181.
APA
Nguyễn Thị, H., Nguyen Minh, T., Peersman, W., Derese, A., & Markuns, J. F. (2018). Development and validation of the Vietnamese primary care assessment tool. PLOS ONE, 13(1). https://doi.org/10.1371/journal.pone.0191181
Chicago author-date
Nguyễn Thị, Hòa, Tam Nguyen Minh, Wim Peersman, Anselme Derese, and Jeffrey F Markuns. 2018. “Development and Validation of the Vietnamese Primary Care Assessment Tool.” PLOS ONE 13 (1). https://doi.org/10.1371/journal.pone.0191181.
Chicago author-date (all authors)
Nguyễn Thị, Hòa, Tam Nguyen Minh, Wim Peersman, Anselme Derese, and Jeffrey F Markuns. 2018. “Development and Validation of the Vietnamese Primary Care Assessment Tool.” PLOS ONE 13 (1). doi:10.1371/journal.pone.0191181.
Vancouver
1.
Nguyễn Thị H, Nguyen Minh T, Peersman W, Derese A, Markuns JF. Development and validation of the Vietnamese primary care assessment tool. PLOS ONE. 2018;13(1).
IEEE
[1]
H. Nguyễn Thị, T. Nguyen Minh, W. Peersman, A. Derese, and J. F. Markuns, “Development and validation of the Vietnamese primary care assessment tool,” PLOS ONE, vol. 13, no. 1, 2018.
@article{8544842,
  abstract     = {{Objective : To adapt the consumer version of the Primary Care Assessment Tool (PCAT) for Vietnam and determine its internal consistency and validity.
Design : A quantitative cross sectional study.
Setting : 56 communes in 3 representative provinces of central Vietnam.
Participants : Total of 3289 people who used health care services at health facility at least once over the past two years.
Results : The Vietnamese adult expanded consumer version of the PCAT (VN PCAT-AE) is an instrument for evaluation of primary care in Vietnam with 70 items comprising six scales representing four core primary care domains, and three additional scales representing three derivative domains. Sixteen other items from the original tool were not included in the final instrument, due to problems with missing values, floor or ceiling effects, and item-total correlations. All the retained scales have a Cronbach’s alpha above 0.70 except for the subscale of Family Centeredness.
Conclusions : The VN PCAT-AE demonstrates adequate internal consistency and validity to be used as an effective tool for measuring the quality of primary care in Vietnam from the consumer perspective. Additional work in the future to optimize valid measurement in all domains consistent with the original version of the tool may be helpful as the primary care system in Vietnam further develops.}},
  articleno    = {{e0191181}},
  author       = {{Nguyễn Thị, Hòa and Nguyen Minh, Tam and Peersman, Wim and Derese, Anselme and Markuns, Jeffrey F}},
  issn         = {{1932-6203}},
  journal      = {{PLOS ONE}},
  keywords     = {{Primary Healthcare,PCAT,assessment,Vietnam,PRIMARY-HEALTH-CARE,QUALITY,COUNTRIES,OUTCOMES,SYSTEMS,VERSION}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{16}},
  title        = {{Development and validation of the Vietnamese primary care assessment tool}},
  url          = {{http://dx.doi.org/10.1371/journal.pone.0191181}},
  volume       = {{13}},
  year         = {{2018}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: