Advanced search
2 files | 2.48 MB Add to list

Application of partial least squares regression for understanding and prediction of fouling in the transfer line heat exchanger of a steam cracker

(2017) p.46-47
Author
Organization

Downloads

  • Applicationofpartialleastsquaresregressionforunderstandingandpredictionoffoulinginthetransferlineheatexchangerofasteamcr.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 2.03 MB
  • Abstract(1).pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 454.00 KB

Citation

Please use this url to cite or link to this publication:

MLA
Ristic, Nenad, et al. Application of Partial Least Squares Regression for Understanding and Prediction of Fouling in the Transfer Line Heat Exchanger of a Steam Cracker. 2017, pp. 46–47.
APA
Ristic, N., Abrahamsson, V., Franz, K., Van Geem, K., & Marin, G. (2017). Application of partial least squares regression for understanding and prediction of fouling in the transfer line heat exchanger of a steam cracker. 46–47.
Chicago author-date
Ristic, Nenad, Victor Abrahamsson, Kristina Franz, Kevin Van Geem, and Guy Marin. 2017. “Application of Partial Least Squares Regression for Understanding and Prediction of Fouling in the Transfer Line Heat Exchanger of a Steam Cracker.” In , 46–47.
Chicago author-date (all authors)
Ristic, Nenad, Victor Abrahamsson, Kristina Franz, Kevin Van Geem, and Guy Marin. 2017. “Application of Partial Least Squares Regression for Understanding and Prediction of Fouling in the Transfer Line Heat Exchanger of a Steam Cracker.” In , 46–47.
Vancouver
1.
Ristic N, Abrahamsson V, Franz K, Van Geem K, Marin G. Application of partial least squares regression for understanding and prediction of fouling in the transfer line heat exchanger of a steam cracker. In 2017. p. 46–7.
IEEE
[1]
N. Ristic, V. Abrahamsson, K. Franz, K. Van Geem, and G. Marin, “Application of partial least squares regression for understanding and prediction of fouling in the transfer line heat exchanger of a steam cracker,” presented at the International Conference on Mathematics in (bio)Chemical Kinetics and Engineering (MaCKiE), Budapest, Hungary, 2017, pp. 46–47.
@inproceedings{8537629,
  author       = {{Ristic, Nenad and Abrahamsson, Victor and Franz, Kristina and Van Geem, Kevin and Marin, Guy}},
  language     = {{eng}},
  location     = {{Budapest, Hungary}},
  pages        = {{46--47}},
  title        = {{Application of partial least squares regression for understanding and prediction of fouling in the transfer line heat exchanger of a steam cracker}},
  year         = {{2017}},
}