Advanced search
2 files | 1.95 MB

Design and calibration of a wearable personal distributed exposimeter for LTE 800-2600 MHz downlink bands

Reza Aminzadeh (UGent) , Arno Thielens (UGent) , Patrick Van Torre (UGent) , Sam Agneessens (UGent) , Matthias Van den Bossche (UGent) , Hendrik Rogier (UGent) , Luc Martens (UGent) and Wout Joseph (UGent)
Author
Organization
Abstract
For the first time, a wearable personal distributed exposimeter (WPDE) is designed and calibrated for the Long-Term Evolution (LTE) 800 and 2600 MHz downlink bands. The proposed WPDE has a 68% confidence interval of 4.8-5.6 dB for different number of antennas and polarizations. Measurements of the WPDE are compared and validated with a commercial exposimeter in a real environment.
Keywords
UHF antennas, biomedical equipment, biomedical measurement, calibration, wearable antennas, LTE downlink bands, WPDE, WPDE measurements, antennas, calibration, frequency 800 MHz to 2600 MHz, long-term evolution, wearable personal distributed exposimeter, Antenna measurements, Apertures, Calibration, Density measurement, Downlink, Power system measurements

Downloads

  • WICA 720a.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 616.61 KB
  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 1.33 MB

Citation

Please use this url to cite or link to this publication:

Chicago
Aminzadeh, Reza, Arno Thielens, Patrick Van Torre, Sam Agneessens, Matthias Van den Bossche, Hendrik Rogier, Luc Martens, and Wout Joseph. 2017. “Design and Calibration of a Wearable Personal Distributed Exposimeter for LTE 800-2600 MHz Downlink Bands.” In 2017 IEEE 14TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN) , 153–156.
APA
Aminzadeh, R., Thielens, A., Van Torre, P., Agneessens, S., Van den Bossche, M., Rogier, H., Martens, L., et al. (2017). Design and calibration of a wearable personal distributed exposimeter for LTE 800-2600 MHz downlink bands. 2017 IEEE 14TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN) (pp. 153–156). Presented at the 14th Annual IEEE International Conference on Wearable and Implantable Body Sensor Networks (BSN) .
Vancouver
1.
Aminzadeh R, Thielens A, Van Torre P, Agneessens S, Van den Bossche M, Rogier H, et al. Design and calibration of a wearable personal distributed exposimeter for LTE 800-2600 MHz downlink bands. 2017 IEEE 14TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN) . 2017. p. 153–6.
MLA
Aminzadeh, Reza et al. “Design and Calibration of a Wearable Personal Distributed Exposimeter for LTE 800-2600 MHz Downlink Bands.” 2017 IEEE 14TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN) . 2017. 153–156. Print.
@inproceedings{8536812,
  abstract     = {For the first time, a wearable personal distributed exposimeter (WPDE) is designed and calibrated for the Long-Term Evolution (LTE) 800 and 2600 MHz downlink bands. The proposed WPDE has a 68\% confidence interval of 4.8-5.6 dB for different number of antennas and polarizations. Measurements of the WPDE are compared and validated with a commercial exposimeter in a real environment.},
  author       = {Aminzadeh, Reza and Thielens, Arno and Van Torre, Patrick and Agneessens, Sam and Van den Bossche, Matthias and Rogier, Hendrik and Martens, Luc and Joseph, Wout},
  booktitle    = {2017 IEEE 14TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN) },
  isbn         = {978-1-5090-6244-7},
  language     = {eng},
  location     = {Eindhoven, The Netherlands},
  pages        = {153--156},
  title        = {Design and calibration of a wearable personal distributed exposimeter for LTE 800-2600 MHz downlink bands},
  url          = {http://dx.doi.org/10.1109/BSN.2017.7936030},
  year         = {2017},
}

Altmetric
View in Altmetric
Web of Science
Times cited: