Advanced search
1 file | 404.17 KB

Determination of the isotopic composition of sub-ng amounts of Sr in Antarctic snow by multi-collector ICP-mass spectrometry

Andrea Bazzano (UGent) , Kris Latruwe (UGent) , Marco Grotti and Frank Vanhaecke (UGent)
Author
Organization
Abstract
Determination of the Sr-87/Sr-86 isotope ratio in Antarctic snow can provide useful information on the sources of the atmospheric particulates in present and ancient times. However, precise and accurate determination of the Sr-87/Sr-86 ratio is challenging because of the low analyte concentration and the limited amount of sample typically available. In this work, Sr was first pre-concentrated 30-fold via evaporation, after which Sr was chromatographically isolated from the matrix (and thus separated from Rb, avoiding isobaric overlap of Sr-87 and Rb-87). Subsequently, the sensitivity of the multi-collector ICP-mass spectrometer was maximized by using an Aridus II membrane desolvating system, a high-transmission interface and 10(12) Omega amplifiers instead of the standard 10(11) Omega ones. With this instrumental setup, the repeatability for Sr-87/Sr-86 ratio measurements was 0.3 and 0.5& RSD at 0.8 ng mL(-1) (or for 320 pg in the 0.4 mL of sample solution consumed) and at 0.4 ng mL(-1) (or for 160 pg) of Sr, respectively. The procedural blank was 2.5 +/- 0.5 pg and did not significantly affect the Sr-87/Sr-86 ratio measured using 160 pg of analyte (at 0.4 ng mL(-1)). The accuracy of the procedure was evaluated via replicate analysis of NIST SRM 987 SrCO3 isotopic reference material. The experimental data agreed with the accepted value within the experimental uncertainty both at 0.8 ng mL(-1) (for 320 pg) and at 0.4 ng mL(-1) (for 160 pg) of Sr. The method was applied to the analysis of Antarctic snow samples (30 g) containing 0.5-2.1 ng of Sr. The precision was fit for the purpose of discriminating between potential source areas (PSAs). The entire procedure required similar to 30 g of snow per sample, potentially enabling the contributions of PSAs to be unravelled with high temporal resolution.
Keywords
EAST ANTARCTICA, SURFACE SNOW, AEOLIAN DUST, STRONTIUM, SAMPLES, PRECISION, SINGLE, DOME, MS, RATIO

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 404.17 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Bazzano, Andrea, Kris Latruwe, Marco Grotti, and Frank Vanhaecke. 2017. “Determination of the Isotopic Composition of Sub-ng Amounts of Sr in Antarctic Snow by Multi-collector ICP-mass Spectrometry.” Journal of Analytical Atomic Spectrometry 32 (5): 1004–1008.
APA
Bazzano, A., Latruwe, K., Grotti, M., & Vanhaecke, F. (2017). Determination of the isotopic composition of sub-ng amounts of Sr in Antarctic snow by multi-collector ICP-mass spectrometry. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 32(5), 1004–1008.
Vancouver
1.
Bazzano A, Latruwe K, Grotti M, Vanhaecke F. Determination of the isotopic composition of sub-ng amounts of Sr in Antarctic snow by multi-collector ICP-mass spectrometry. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY. 2017;32(5):1004–8.
MLA
Bazzano, Andrea, Kris Latruwe, Marco Grotti, et al. “Determination of the Isotopic Composition of Sub-ng Amounts of Sr in Antarctic Snow by Multi-collector ICP-mass Spectrometry.” JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY 32.5 (2017): 1004–1008. Print.
@article{8528219,
  abstract     = {Determination of the Sr-87/Sr-86 isotope ratio in Antarctic snow can provide useful information on the sources of the atmospheric particulates in present and ancient times. However, precise and accurate determination of the Sr-87/Sr-86 ratio is challenging because of the low analyte concentration and the limited amount of sample typically available. In this work, Sr was first pre-concentrated 30-fold via evaporation, after which Sr was chromatographically isolated from the matrix (and thus separated from Rb, avoiding isobaric overlap of Sr-87 and Rb-87). Subsequently, the sensitivity of the multi-collector ICP-mass spectrometer was maximized by using an Aridus II membrane desolvating system, a high-transmission interface and 10(12) Omega amplifiers instead of the standard 10(11) Omega ones. With this instrumental setup, the repeatability for Sr-87/Sr-86 ratio measurements was 0.3 and 0.5\& RSD at 0.8 ng mL(-1) (or for 320 pg in the 0.4 mL of sample solution consumed) and at 0.4 ng mL(-1) (or for 160 pg) of Sr, respectively. The procedural blank was 2.5 +/- 0.5 pg and did not significantly affect the Sr-87/Sr-86 ratio measured using 160 pg of analyte (at 0.4 ng mL(-1)). The accuracy of the procedure was evaluated via replicate analysis of NIST SRM 987 SrCO3 isotopic reference material. The experimental data agreed with the accepted value within the experimental uncertainty both at 0.8 ng mL(-1) (for 320 pg) and at 0.4 ng mL(-1) (for 160 pg) of Sr. The method was applied to the analysis of Antarctic snow samples (30 g) containing 0.5-2.1 ng of Sr. The precision was fit for the purpose of discriminating between potential source areas (PSAs). The entire procedure required similar to 30 g of snow per sample, potentially enabling the contributions of PSAs to be unravelled with high temporal resolution.},
  author       = {Bazzano, Andrea and Latruwe, Kris and Grotti, Marco and Vanhaecke, Frank},
  issn         = {0267-9477},
  journal      = {JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY},
  language     = {eng},
  number       = {5},
  pages        = {1004--1008},
  title        = {Determination of the isotopic composition of sub-ng amounts of Sr in Antarctic snow by multi-collector ICP-mass spectrometry},
  url          = {http://dx.doi.org/10.1039/c7ja00062f},
  volume       = {32},
  year         = {2017},
}

Altmetric
View in Altmetric
Web of Science
Times cited: