Advanced search
1 file | 460.92 KB Add to list
Author
Organization
Abstract
During the future LHC upgrade planned in 2018, the forward endcap region of the CMS muon spectrometer will be upgraded with GEM chambers. GEM technology is able to withstand the radiation environment expected in the forward region. The GE1/1 station will be included in the muon L1 trigger, allowing to keep low p(T) threshold even at high luminosity. Moreover, it will bring detection redundancy in the most critical part of the CMS muon system, along with benefits to muon reconstruction performance.

Downloads

  • CMSMichael9.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 460.92 KB

Citation

Please use this url to cite or link to this publication:

MLA
Magnani, A., et al. “Impact of the GE1/1 Upgrade on CMS Muon System Performance.” NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, vol. 39, no. 1, 2016, doi:10.1393/ncc/i2016-16260-7.
APA
Magnani, A., Abbaneo, D., Abbas, M., Abbrescia, M., Abdelalim, A. A., Akl, M. A., … Zhang, A. (2016). Impact of the GE1/1 upgrade on CMS muon system performance. NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 39(1). https://doi.org/10.1393/ncc/i2016-16260-7
Chicago author-date
Magnani, A., D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, O. Aboamer, et al. 2016. “Impact of the GE1/1 Upgrade on CMS Muon System Performance.” NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS 39 (1). https://doi.org/10.1393/ncc/i2016-16260-7.
Chicago author-date (all authors)
Magnani, A., D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, A. Braghieri, S. Braibant, S. Buontempo, C. Calabria, M. Caponero, C. Caputo, F. Cassese, A. Castaneda, S. Cauwenbergh, F. R. Cavallo, A. Celik, M. Choi, S. Choi, J. Christiansen, Anna Cimmino, S. Colafranceschi, A. Colaleo, A. Conde Garcia, S. Czellar, M. M. Dabrowski, G. De Lentdecker, R. De Oliveira, G. de Robertis, S. Dildick, B. Dorney, W. Elmetenawee, G. Endroczi, F. Errico, A. Fenyvesi, S. Ferry, I. Furic, P. Giacomelli, J. Gilmore, V. Golovtsov, L. Guiducci, F. Guilloux, A. Gutierrez, R. M. Hadjiiska, A. Hassan, J. Hauser, K. Hoepfner, M. Hohlmann, H. Hoorani, P. Iaydjiev, Y. G. Jeng, T. Kamon, P. Karchin, A. Korytov, S. Krutelyov, A. Kumar, H. Kim, J. Lee, T. Lenzi, L. Litov, F. Loddo, A. Madorsky, T. Maerschalk, M. Maggi, P. K. Mal, K. Mandal, A. Marchioro, A. Marinov, R. Masod, N. Majumdar, J. A. Merlin, G. Mitselmakher, A. K. Mohanty, S. Mohamed, A. Mohapatra, J. Molnar, S. Muhammad, S. Mukhopadhyay, M. Naimuddin, S. Nuzzo, E. Oliveri, L. M. Pant, P. Paolucci, I. Park, G. Passeggio, B. Pavlov, B. Philipps, D. Piccolo, H. Postema, A. Puig Baranac, A. Radi, R. Radogna, G. Raffone, A. Ranieri, G. Rashevski, C. Riccardi, M. Rodozov, A. Rodrigues, L. Ropelewski, S. RoyChowdhury, G. Ryu, M. S. Ryu, A. Safonov, S. Salva, G. Saviano, A. Sharma, A. Sharma, R. Sharma, A. H. Sha, M. Shopova, J. Sturdy, G. Sultanov, S. K. Swain, Z. Szillasi, J. Talvitie, A. Tatarinov, T. Tuuva, Michael Tytgat, I. Vai, M. Van Stenis, R. Venditti, E. Verhagen, P. Verwilligen, P. Vitulo, S. Volkov, A. Vorobyev, D. Wang, M. Wang, U. Yang, Y. Yang, R. Yonamine, Nikolaos Zaganidis, F. Zenoni, and A. Zhang. 2016. “Impact of the GE1/1 Upgrade on CMS Muon System Performance.” NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS 39 (1). doi:10.1393/ncc/i2016-16260-7.
Vancouver
1.
Magnani A, Abbaneo D, Abbas M, Abbrescia M, Abdelalim AA, Akl MA, et al. Impact of the GE1/1 upgrade on CMS muon system performance. NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS. 2016;39(1).
IEEE
[1]
A. Magnani et al., “Impact of the GE1/1 upgrade on CMS muon system performance,” NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, vol. 39, no. 1, 2016.
@article{8523507,
  abstract     = {{During the future LHC upgrade planned in 2018, the forward endcap region of the CMS muon spectrometer will be upgraded with GEM chambers. GEM technology is able to withstand the radiation environment expected in the forward region. The GE1/1 station will be included in the muon L1 trigger, allowing to keep low p(T) threshold even at high luminosity. Moreover, it will bring detection redundancy in the most critical part of the CMS muon system, along with benefits to muon reconstruction performance.}},
  articleno    = {{260}},
  author       = {{Magnani, A. and Abbaneo, D. and Abbas, M. and Abbrescia, M. and Abdelalim, A. A. and Akl, M. Abi and Aboamer, O. and Acosta, D. and Ahmad, A. and Ahmed, W. and Ahmed, W. and Aleksandrov, A. and Aly, R. and Altieri, P. and Asawatangtrakuldee, C. and Aspell, P. and Assran, Y. and Awan, I. and Bally, S. and Ban, Y. and Banerjee, S. and Barashko, V. and Barria, P. and Bencze, G. and Beni, N. and Benussi, L. and Bhopatkar, V. and Bianco, S. and Bos, J. and Bouhali, O. and Braghieri, A. and Braibant, S. and Buontempo, S. and Calabria, C. and Caponero, M. and Caputo, C. and Cassese, F. and Castaneda, A. and Cauwenbergh, S. and Cavallo, F. R. and Celik, A. and Choi, M. and Choi, S. and Christiansen, J. and Cimmino, Anna and Colafranceschi, S. and Colaleo, A. and Garcia, A. Conde and Czellar, S. and Dabrowski, M. M. and De Lentdecker, G. and De Oliveira, R. and de Robertis, G. and Dildick, S. and Dorney, B. and Elmetenawee, W. and Endroczi, G. and Errico, F. and Fenyvesi, A. and Ferry, S. and Furic, I. and Giacomelli, P. and Gilmore, J. and Golovtsov, V. and Guiducci, L. and Guilloux, F. and Gutierrez, A. and Hadjiiska, R. M. and Hassan, A. and Hauser, J. and Hoepfner, K. and Hohlmann, M. and Hoorani, H. and Iaydjiev, P. and Jeng, Y. G. and Kamon, T. and Karchin, P. and Korytov, A. and Krutelyov, S. and Kumar, A. and Kim, H. and Lee, J. and Lenzi, T. and Litov, L. and Loddo, F. and Madorsky, A. and Maerschalk, T. and Maggi, M. and Mal, P. K. and Mandal, K. and Marchioro, A. and Marinov, A. and Masod, R. and Majumdar, N. and Merlin, J. A. and Mitselmakher, G. and Mohanty, A. K. and Mohamed, S. and Mohapatra, A. and Molnar, J. and Muhammad, S. and Mukhopadhyay, S. and Naimuddin, M. and Nuzzo, S. and Oliveri, E. and Pant, L. M. and Paolucci, P. and Park, I. and Passeggio, G. and Pavlov, B. and Philipps, B. and Piccolo, D. and Postema, H. and Baranac, A. Puig and Radi, A. and Radogna, R. and Raffone, G. and Ranieri, A. and Rashevski, G. and Riccardi, C. and Rodozov, M. and Rodrigues, A. and Ropelewski, L. and RoyChowdhury, S. and Ryu, G. and Ryu, M. S. and Safonov, A. and Salva, S. and Saviano, G. and Sharma, A. and Sharma, A. and Sharma, R. and Sha, A. H. and Shopova, M. and Sturdy, J. and Sultanov, G. and Swain, S. K. and Szillasi, Z. and Talvitie, J. and Tatarinov, A. and Tuuva, T. and Tytgat, Michael and Vai, I. and Van Stenis, M. and Venditti, R. and Verhagen, E. and Verwilligen, P. and Vitulo, P. and Volkov, S. and Vorobyev, A. and Wang, D. and Wang, M. and Yang, U. and Yang, Y. and Yonamine, R. and Zaganidis, Nikolaos and Zenoni, F. and Zhang, A.}},
  issn         = {{2037-4909}},
  journal      = {{NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{5}},
  title        = {{Impact of the GE1/1 upgrade on CMS muon system performance}},
  url          = {{http://doi.org/10.1393/ncc/i2016-16260-7}},
  volume       = {{39}},
  year         = {{2016}},
}

Altmetric
View in Altmetric