Ghent University Academic Bibliography

Advanced

Detector control system and efficiency performance for CMS RPC at GIF++

Muhammad Gul UGent, G Gonzalez Blanco, Anna Cimmino, Shannon Rebecca Crucy, Alexis Fagot, Alberto Andres Ocampo Rios, Michael Tytgat UGent, Nikolaos Zaganidis UGent, S Aly, Y Assran, et al. (2016) JOURNAL OF INSTRUMENTATION. 11(10).
abstract
In the framework of the High Luminosity LHC upgrade program, the CMS muon group built several different RPC prototypes that are now under test at the new CERN Gamma Irradiation Facility (GIF++). A dedicated Detector Control System (DCS) has been developed using the WinCC-OA tool to control and monitor these prototype detectors and to store the measured parameters data. Preliminary efficiency studies that set the base performance measurements of CMS RPC for starting aging studies are also presented.
Please use this url to cite or link to this publication:
author
organization
alternative title
Detector control system and efficiency performance for CMS RPC at GIF plus
year
type
journalArticle (proceedingsPaper)
publication status
published
subject
keyword
Detector control systems (detector and experiment monitoring and slow-control systems, architecture, hardware, algorithms, databases), Resistive-plate chambers
journal title
JOURNAL OF INSTRUMENTATION
J. Instrum.
volume
11
issue
10
article number
C10013
pages
9 pages
conference name
13th Workshop on Resistive Plate Chambers and Related Detectors
conference location
Ghent, Belgium
conference start
2016-02-22
conference end
2016-02-26
Web of Science type
Article; Proceedings Paper
Web of Science id
000387876200013
JCR category
INSTRUMENTS & INSTRUMENTATION
JCR impact factor
1.22 (2016)
JCR rank
40/58 (2016)
JCR quartile
3 (2016)
ISSN
1748-0221
DOI
10.1088/1748-0221/11/10/c10013
language
English
UGent publication?
yes
classification
A1
copyright statement
I have transferred the copyright for this publication to the publisher
id
8523429
handle
http://hdl.handle.net/1854/LU-8523429
date created
2017-06-13 08:11:10
date last changed
2017-11-03 23:30:10
@article{8523429,
  abstract     = {In the framework of the High Luminosity LHC upgrade program, the CMS muon group built several different RPC prototypes that are now under test at the new CERN Gamma Irradiation Facility (GIF++). A dedicated Detector Control System (DCS) has been developed using the WinCC-OA tool to control and monitor these prototype detectors and to store the measured parameters data. Preliminary efficiency studies that set the base performance measurements of CMS RPC for starting aging studies are also presented.},
  articleno    = {C10013},
  author       = {Gul, Muhammad and Gonzalez Blanco, G and Cimmino, Anna and Crucy, Shannon Rebecca and Fagot, Alexis and Ocampo Rios, Alberto Andres and Tytgat, Michael and Zaganidis, Nikolaos and Aly, S and Assran, Y and Radi, A and Sayed, A and Singh, G and Abbrescia, M and Iaselli, G and Maggi, M and Pugliese, G and Verwilligen, P and Van Doninck, W and Colafranceschi, S and Sharma, A and Benussi, L and Bianco, S and Piccolo, D and Primavera, F and Bhatnagar, V and Kumari, R and Mehta, A and Singh, J and Ahmad, A and Asghar, MI and Muhammad, S and Awan, IM and Hoorani, HR and Ahmed, W and Shahzad, H and Shah, MA and Cho, SW and Choi, SY and Hong, B and Kang, MH and Lee, KS and Lim, JH and Park, SK and Kim, MS and Goutzvitz, M and Grenier, G and Lagarde, F and Lagarde, F and Estrada, CU and Pedraza, I and Severiano, CB and Carrillo Moreno, S and Vazquez Valencia, F and Pant, LM and Buontempo, S and Cavallo, N and Esposito, M and Fabozzi, F and Lanza, G and Lista, L and Meola, S and Merola, M and Orso, I and Paolucci, P and Thyssen, F and Braghieri, A and Magnani, A and Montagna, P and Riccardi, C and Salvini, P and Vai, I and Vitulo, P and Ban, Y and Qian, SJ and Choi, M and Choi, Y and Goh, J and Kim, D and Aleksandrov, A and Hadjiiska, R and Iaydjiev, P and Rodozov, M and Stoykova, S and Sultanov, G and Vutova, M and Dimitrov, A and Litov, L and Pavlov, B and Petkov, P and Lomidze, D and Bagaturia, I and Avila, C and Cabrera, A and Sanabria, JC and Crotty, I and Vaitkus, J},
  issn         = {1748-0221},
  journal      = {JOURNAL OF INSTRUMENTATION},
  keyword      = {Detector control systems (detector and experiment monitoring and slow-control systems,architecture,hardware,algorithms,databases),Resistive-plate chambers},
  language     = {eng},
  location     = {Ghent, Belgium},
  number       = {10},
  pages        = {9},
  title        = {Detector control system and efficiency performance for CMS RPC at GIF++},
  url          = {http://dx.doi.org/10.1088/1748-0221/11/10/c10013},
  volume       = {11},
  year         = {2016},
}

Chicago
Gul, Muhammad, G Gonzalez Blanco, Anna Cimmino, Shannon Rebecca Crucy, Alexis Fagot, Alberto Andres Ocampo Rios, Michael Tytgat, et al. 2016. “Detector Control System and Efficiency Performance for CMS RPC at GIF++.” Journal of Instrumentation 11 (10).
APA
Gul, M., Gonzalez Blanco, G., Cimmino, A., Crucy, S. R., Fagot, A., Ocampo Rios, A. A., Tytgat, M., et al. (2016). Detector control system and efficiency performance for CMS RPC at GIF++. JOURNAL OF INSTRUMENTATION, 11(10). Presented at the 13th Workshop on Resistive Plate Chambers and Related Detectors.
Vancouver
1.
Gul M, Gonzalez Blanco G, Cimmino A, Crucy SR, Fagot A, Ocampo Rios AA, et al. Detector control system and efficiency performance for CMS RPC at GIF++. JOURNAL OF INSTRUMENTATION. 2016;11(10).
MLA