Advanced search
2 files | 3.32 MB

Evaluation of spin freezing versus conventional freezing as part of a continuous pharmaceutical freeze-drying concept for unit doses

Author
Organization
Keywords
Freeze-drying, Continuous freeze drying, Spin freezing, NIR spectroscopy, NEAR-INFRARED SPECTROSCOPY, PRODUCT TEMPERATURE, LYOPHILIZATION

Downloads

  • Evaluation.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 1.33 MB
  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 1.99 MB

Citation

Please use this url to cite or link to this publication:

Chicago
De Meyer, Laurens, Pieter-Jan Van Bockstal, Jos Corver, Chris Vervaet, Jean Paul Remon, and Thomas De Beer. 2015. “Evaluation of Spin Freezing Versus Conventional Freezing as Part of a Continuous Pharmaceutical Freeze-drying Concept for Unit Doses.” International Journal of Pharmaceutics 496 (1): 75–85.
APA
De Meyer, Laurens, Van Bockstal, P.-J., Corver, J., Vervaet, C., Remon, J. P., & De Beer, T. (2015). Evaluation of spin freezing versus conventional freezing as part of a continuous pharmaceutical freeze-drying concept for unit doses. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 496(1), 75–85.
Vancouver
1.
De Meyer L, Van Bockstal P-J, Corver J, Vervaet C, Remon JP, De Beer T. Evaluation of spin freezing versus conventional freezing as part of a continuous pharmaceutical freeze-drying concept for unit doses. INTERNATIONAL JOURNAL OF PHARMACEUTICS. 2015;496(1):75–85.
MLA
De Meyer, Laurens, Pieter-Jan Van Bockstal, Jos Corver, et al. “Evaluation of Spin Freezing Versus Conventional Freezing as Part of a Continuous Pharmaceutical Freeze-drying Concept for Unit Doses.” INTERNATIONAL JOURNAL OF PHARMACEUTICS 496.1 (2015): 75–85. Print.
@article{8507440,
  author       = {De Meyer, Laurens and Van Bockstal, Pieter-Jan and Corver, Jos and Vervaet, Chris and Remon, Jean Paul and De Beer, Thomas},
  issn         = {0378-5173},
  journal      = {INTERNATIONAL JOURNAL OF PHARMACEUTICS},
  keyword      = {Freeze-drying,Continuous freeze drying,Spin freezing,NIR spectroscopy,NEAR-INFRARED SPECTROSCOPY,PRODUCT TEMPERATURE,LYOPHILIZATION},
  language     = {eng},
  number       = {1},
  pages        = {75--85},
  title        = {Evaluation of spin freezing versus conventional freezing as part of a continuous pharmaceutical freeze-drying concept for unit doses},
  url          = {http://dx.doi.org/10.1016/j.ijpharm.2015.05.025},
  volume       = {496},
  year         = {2015},
}

Altmetric
View in Altmetric
Web of Science
Times cited: