Advanced search
1 file | 631.71 KB

Effects of design and operational parameters on ammonium removal by single-stage French vertical flow filters treating raw domestic wastewater

(2016) ECOLOGICAL ENGINEERING. 97. p.516-523
Author
Organization
Keywords
Ammonium, Vertical flow constructed wetland, Domestic wastewater, Design, TOTAL NITROGEN REMOVAL, CONSTRUCTED WETLANDS, TREATMENT PERFORMANCES, RECIRCULATION, SORPTION

Downloads

  • ECOLENG-D-16-00362R1.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 631.71 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Millot, Yoann, Stéphane Troesch, Dirk Esser, Pascal Molle, Ania Morvannou, Rémy Gourdon, and Diederik Rousseau. 2016. “Effects of Design and Operational Parameters on Ammonium Removal by Single-stage French Vertical Flow Filters Treating Raw Domestic Wastewater.” Ecological Engineering 97: 516–523.
APA
Millot, Y., Troesch, S., Esser, D., Molle, P., Morvannou, A., Gourdon, R., & Rousseau, D. (2016). Effects of design and operational parameters on ammonium removal by single-stage French vertical flow filters treating raw domestic wastewater. ECOLOGICAL ENGINEERING, 97, 516–523.
Vancouver
1.
Millot Y, Troesch S, Esser D, Molle P, Morvannou A, Gourdon R, et al. Effects of design and operational parameters on ammonium removal by single-stage French vertical flow filters treating raw domestic wastewater. ECOLOGICAL ENGINEERING. 2016;97:516–23.
MLA
Millot, Yoann, Stéphane Troesch, Dirk Esser, et al. “Effects of Design and Operational Parameters on Ammonium Removal by Single-stage French Vertical Flow Filters Treating Raw Domestic Wastewater.” ECOLOGICAL ENGINEERING 97 (2016): 516–523. Print.
@article{8503147,
  author       = {Millot, Yoann and Troesch, St{\'e}phane and Esser, Dirk and Molle, Pascal and Morvannou, Ania and Gourdon, R{\'e}my and Rousseau, Diederik},
  issn         = {0925-8574},
  journal      = {ECOLOGICAL ENGINEERING},
  keyword      = {Ammonium,Vertical flow constructed wetland,Domestic wastewater,Design,TOTAL NITROGEN REMOVAL,CONSTRUCTED WETLANDS,TREATMENT PERFORMANCES,RECIRCULATION,SORPTION},
  language     = {eng},
  pages        = {516--523},
  title        = {Effects of design and operational parameters on ammonium removal by single-stage French vertical flow filters treating raw domestic wastewater},
  url          = {http://dx.doi.org/10.1016/j.ecoleng.2016.10.002},
  volume       = {97},
  year         = {2016},
}

Altmetric
View in Altmetric
Web of Science
Times cited: