Reproducibility study of normoxic polyacrylamide gel (nPAG) dosimeters

Giuliana Russo, Jan Vandecasteele UGent, TOM VERCAUTEREN UGent, Salvatore De Pasquale and Yves De Deene UGent (2009) JOURNAL OF PHYSICS CONFERENCE SERIES. 164(1).
abstract
In this study, the overall accuracy of normoxic polyacrylamide gel (nPAG) dosimeters is considered. Different badges of nPAG are fabricated, poured in containers of glass and Barex" and irradiated with a 6MV square photon beam. The polymer gel dosimeters were read out using MRI. The overall reproducibility and accuracy of nPAG gel dosimeters was determined by comparison with depth-dose profiles acquired with a Pin Point ionization chamber. Additionally, the effect of the container wall on the depth-dose profile and the effect of temperature changes before and after irradiation on the R2-dose response have been investigated. The average standard deviation and maximum deviation between 8 gel-measured depth-dose profiles and a depth-dose profile measured with an ionization chamber amounted to 0.543 Gy (2.5%) and 2.579 Gy (11.7%) respectively.
Please use this url to cite or link to this publication:
author
organization
year
type
conference
publication status
published
subject
keyword
ionisation chambers, dosimeters, polymer gels, nPAG dosimeters, pin point ionization chamber, depth-dose profiles, MRI
in
JOURNAL OF PHYSICS CONFERENCE SERIES
J. Phys. Conf. Ser.
volume
164
issue
1
article_number
012010
pages
5 pages
publisher
IOP
place of publication
Bristol, UK
conference name
5th International conference on Radiotherapy Gel Dosimetry (DOSGEL 2008)
conference location
Hersonissos, Crete, Greece
conference start
2008-09-29
conference end
2008-10-03
ISSN
1742-6596
DOI
10.1088/1742-6596/164/1/012010
language
English
UGent publication?
yes
classification
C1
copyright statement
I have transferred the copyright for this publication to the publisher
id
841706
handle
http://hdl.handle.net/1854/LU-841706
date created
2010-01-27 09:33:22
date last changed
2011-07-26 09:45:15
@inproceedings{841706,
  abstract     = {In this study, the overall accuracy of normoxic polyacrylamide gel (nPAG) dosimeters is considered. Different badges of nPAG are fabricated, poured in containers of glass and Barex{\textacutedbl} and irradiated with a 6MV square photon beam. The polymer gel dosimeters were read out using MRI. The overall reproducibility and accuracy of nPAG gel dosimeters was determined by comparison with depth-dose profiles acquired with a Pin Point ionization chamber. Additionally, the effect of the container wall on the depth-dose profile and the effect of temperature changes before and after irradiation on the R2-dose response have been investigated. The average standard deviation and maximum deviation between 8 gel-measured depth-dose profiles and a depth-dose profile measured with an ionization chamber amounted to 0.543 Gy (2.5\%) and 2.579 Gy (11.7\%) respectively.},
  articleno    = {012010},
  author       = {Russo, Giuliana and Vandecasteele, Jan and VERCAUTEREN, TOM and De Pasquale, Salvatore and De Deene, Yves},
  booktitle    = {JOURNAL OF PHYSICS CONFERENCE SERIES},
  issn         = {1742-6596},
  keyword      = {ionisation chambers,dosimeters,polymer gels,nPAG dosimeters,pin point ionization chamber,depth-dose profiles,MRI},
  language     = {eng},
  location     = {Hersonissos, Crete, Greece},
  number       = {1},
  pages        = {5},
  publisher    = {IOP},
  title        = {Reproducibility study of normoxic polyacrylamide gel (nPAG) dosimeters},
  url          = {http://dx.doi.org/10.1088/1742-6596/164/1/012010},
  volume       = {164},
  year         = {2009},
}

Chicago
Russo, Giuliana, Jan Vandecasteele, TOM VERCAUTEREN, Salvatore De Pasquale, and Yves De Deene. 2009. “Reproducibility Study of Normoxic Polyacrylamide Gel (nPAG) Dosimeters.” In Journal of Physics Conference Series. Vol. 164. Bristol, UK: IOP.
APA
Russo, G., Vandecasteele, J., VERCAUTEREN, T., De Pasquale, S., & De Deene, Y. (2009). Reproducibility study of normoxic polyacrylamide gel (nPAG) dosimeters. JOURNAL OF PHYSICS CONFERENCE SERIES (Vol. 164). Presented at the 5th International conference on Radiotherapy Gel Dosimetry (DOSGEL 2008), Bristol, UK: IOP.
Vancouver
1.
Russo G, Vandecasteele J, VERCAUTEREN T, De Pasquale S, De Deene Y. Reproducibility study of normoxic polyacrylamide gel (nPAG) dosimeters. JOURNAL OF PHYSICS CONFERENCE SERIES. Bristol, UK: IOP; 2009.
MLA
Russo, Giuliana, Jan Vandecasteele, TOM VERCAUTEREN, et al. “Reproducibility Study of Normoxic Polyacrylamide Gel (nPAG) Dosimeters.” Journal of Physics Conference Series. Vol. 164. Bristol, UK: IOP, 2009. Print.