Advanced search
1 file | 133.46 KB

Use of remote monitoring in the management of system-related complications in implantable defibrillator patients

(2012) NETHERLANDS HEART JOURNAL. 20(2). p.82-85
Author
Organization
Abstract
Remote monitoring of implantable defibrillators (ICDs) is designed to minimise regular follow-up visits and to facilitate early detection of adverse events. With the increased rate of ICD implantations in today's clinical setting and multiple device advisories, which pose management challenges, this approach becomes very attractive. The aim of this article is to present the role of remote monitoring in the detection of system-related complications, its potential benefits and its barriers in the outpatient management of ICD patients.
Keywords
Remote monitoring, REDUCE INAPPROPRIATE SHOCKS, Lead failure, Arrhythmias, Complications, CARDIAC-RESYNCHRONIZATION THERAPY, SOCIETY TASK-FORCE, CARDIOVERTER-DEFIBRILLATOR, FOLLOW-UP, PROPHYLACTIC IMPLANTATION, PERFORMANCE POLICIES, HEART-FAILURE, LEAD FAILURE, RECOMMENDATIONS, Implantable cardioverter-defibrillator

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 133.46 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Theuns, Dominic AMJ, and Luc Jordaens. 2012. “Use of Remote Monitoring in the Management of System-related Complications in Implantable Defibrillator Patients.” Netherlands Heart Journal 20 (2): 82–85.
APA
Theuns, D. A., & Jordaens, L. (2012). Use of remote monitoring in the management of system-related complications in implantable defibrillator patients. NETHERLANDS HEART JOURNAL, 20(2), 82–85.
Vancouver
1.
Theuns DA, Jordaens L. Use of remote monitoring in the management of system-related complications in implantable defibrillator patients. NETHERLANDS HEART JOURNAL. 2012;20(2):82–5.
MLA
Theuns, Dominic AMJ, and Luc Jordaens. “Use of Remote Monitoring in the Management of System-related Complications in Implantable Defibrillator Patients.” NETHERLANDS HEART JOURNAL 20.2 (2012): 82–85. Print.
@article{8124211,
  abstract     = {Remote monitoring of implantable defibrillators (ICDs) is designed to minimise regular follow-up visits and to facilitate early detection of adverse events. With the increased rate of ICD implantations in today's clinical setting and multiple device advisories, which pose management challenges, this approach becomes very attractive. The aim of this article is to present the role of remote monitoring in the detection of system-related complications, its potential benefits and its barriers in the outpatient management of ICD patients.},
  author       = {Theuns, Dominic AMJ and Jordaens, Luc},
  issn         = {1568-5888},
  journal      = {NETHERLANDS HEART JOURNAL},
  keywords     = {Remote monitoring,REDUCE INAPPROPRIATE SHOCKS,Lead failure,Arrhythmias,Complications,CARDIAC-RESYNCHRONIZATION THERAPY,SOCIETY TASK-FORCE,CARDIOVERTER-DEFIBRILLATOR,FOLLOW-UP,PROPHYLACTIC IMPLANTATION,PERFORMANCE POLICIES,HEART-FAILURE,LEAD FAILURE,RECOMMENDATIONS,Implantable cardioverter-defibrillator},
  language     = {eng},
  number       = {2},
  pages        = {82--85},
  title        = {Use of remote monitoring in the management of system-related complications in implantable defibrillator patients},
  url          = {http://dx.doi.org/10.1007/s12471-011-0228-8},
  volume       = {20},
  year         = {2012},
}

Altmetric
View in Altmetric
Web of Science
Times cited: