In-line NDT with X-Ray CT combining sample rotation and translation

(2016) NDT & E INTERNATIONAL. 84. p.89-98
Author
Organization
Keywords
In-line, Iterative reconstruction, Inspection systems, X-ray tomography

Downloads

  • manuscript conveyor belt CT.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 3.09 MB

Citation

Please use this url to cite or link to this publication:

Chicago
De Schryver, Thomas, Jelle Dhaene, Manuel Dierick, Matthieu Boone, Eline Janssens, Jan Sijbers, Mattias van Dael, Pieter Verboven, Bart Nicolai, and Luc Van Hoorebeke. 2016. “In-line NDT with X-Ray CT Combining Sample Rotation and Translation.” Ndt & E International 84: 89–98.
APA
De Schryver, T., Dhaene, J., Dierick, M., Boone, M., Janssens, E., Sijbers, J., van Dael, M., et al. (2016). In-line NDT with X-Ray CT combining sample rotation and translation. NDT & E INTERNATIONAL, 84, 89–98.
Vancouver
1.
De Schryver T, Dhaene J, Dierick M, Boone M, Janssens E, Sijbers J, et al. In-line NDT with X-Ray CT combining sample rotation and translation. NDT & E INTERNATIONAL. 2016;84:89–98.
MLA
De Schryver, Thomas et al. “In-line NDT with X-Ray CT Combining Sample Rotation and Translation.” NDT & E INTERNATIONAL 84 (2016): 89–98. Print.
@article{8083830,
  author       = {De Schryver, Thomas and Dhaene, Jelle and Dierick, Manuel and Boone, Matthieu and Janssens, Eline and Sijbers, Jan and van Dael, Mattias and Verboven, Pieter and Nicolai, Bart and Van Hoorebeke, Luc},
  issn         = {0963-8695},
  journal      = {NDT & E INTERNATIONAL},
  keywords     = {In-line,Iterative reconstruction,Inspection systems,X-ray tomography},
  language     = {eng},
  pages        = {89--98},
  title        = {In-line NDT with X-Ray CT combining sample rotation and translation},
  url          = {http://dx.doi.org/10.1016/j.ndteint.2016.09.001},
  volume       = {84},
  year         = {2016},
}

Altmetric
View in Altmetric
Web of Science
Times cited: