EPI-CT: in vitro assessment of the applicability of the γ-H2AX-foci assay as cellular biomarker for exposure in a multicentre study of children in diagnostic radiology
- Author
- Charlot Vandevoorde (UGent) , Maria Gomolka, Ute Roessler, Daniel Samaga, Carita Lindholm, Maria Fernet, Janet Hall, Eileen Pernot, Houssein El Saghire (UGent) , Sarah Baatout (UGent) , Ausrele Kesminiene and Hubert Thierens (UGent)
- Organization
- Project
-
- EPI-CT (Epidemiological study to quantify risks for paediatric computerized tomography and to optimise doses)
- Abstract
- Purpose : To conduct a feasibility study on the application of the gamma-H2AX foci assay as an exposure biomarker in a prospective multicentre paediatric radiology setting. Materials and methods : A set of in vitro experiments was performed to evaluate technical hurdles related to biological sample collection in a paediatric radiology setting (small blood sample volume), processing and storing of blood samples (effect of storing blood at 4 degrees C), the reliability of foci scoring for low-doses (merge gamma-H2AX/53BP1 scoring), as well as the impact of contrast agent administration as potential confounding factor. Given the exploratory nature of this study and the ethical constraints related to paediatric blood sampling, blood samples from adult volunteers were used for these experiments. In order to test the feasibility of pooling the gamma-H2AX data when different centres are involved in an international multicentre study, two intercomparison studies in the low-dose range (10-500 mGy) were performed. Results : Determination of the number of X-ray induced gamma-H2AX foci is feasible with one 2 ml blood sample pre- and post-computed tomography (CT) scan. Lymphocyte isolation and fixation on slides is necessary within 5 h of blood sampling to guarantee reliable results. The possible enhancement effect of contrast medium on the induction of DNA DSB in a patient study can be ruled out if radiation doses and the contrast agent concentration are within diagnostic ranges. The intercomparison studies using in vitro irradiated blood samples showed that the participating laboratories, executing successfully the gamma-H2AX foci assay in lymphocytes, were able to rank blind samples in order of lowest to highest radiation dose based on mean foci/cell counts. The dose response of all intercomparison data shows that a dose point of 10 mGy could be distinguished from the sham-irradiated control (p = 0.006). Conclusions : The results demonstrate that it is feasible to apply the gamma-H2AX foci assay as a cellular biomarker of exposure in a multicentre prospective study in paediatric CT imaging after validating it in an in vivo international pilot study on paediatric patients.
- Keywords
- molecular radiobiology, low dose eff ects, DNA damage, computed tomography, gamma-H2AX foci, epidemiology, ATOMIC-BOMB SURVIVORS, DOUBLE-STRAND BREAKS, HISTONE H2AX PHOSPHORYLATION, IONIZING-RADIATION EXPOSURE, COMPUTED-TOMOGRAPHY, DNA-DAMAGE, CANCER INCIDENCE, SUBSEQUENT RISK, FOCI, LYMPHOCYTES
Downloads
-
(...).pdf
- full text
- |
- UGent only
- |
- |
- 2.41 MB
Citation
Please use this url to cite or link to this publication: http://hdl.handle.net/1854/LU-7248000
- MLA
- Vandevoorde, Charlot, et al. “EPI-CT: In Vitro Assessment of the Applicability of the γ-H2AX-Foci Assay as Cellular Biomarker for Exposure in a Multicentre Study of Children in Diagnostic Radiology.” INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, vol. 91, no. 8, 2015, pp. 653–63, doi:10.3109/09553002.2015.1047987.
- APA
- Vandevoorde, C., Gomolka, M., Roessler, U., Samaga, D., Lindholm, C., Fernet, M., … Thierens, H. (2015). EPI-CT: in vitro assessment of the applicability of the γ-H2AX-foci assay as cellular biomarker for exposure in a multicentre study of children in diagnostic radiology. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 91(8), 653–663. https://doi.org/10.3109/09553002.2015.1047987
- Chicago author-date
- Vandevoorde, Charlot, Maria Gomolka, Ute Roessler, Daniel Samaga, Carita Lindholm, Maria Fernet, Janet Hall, et al. 2015. “EPI-CT: In Vitro Assessment of the Applicability of the γ-H2AX-Foci Assay as Cellular Biomarker for Exposure in a Multicentre Study of Children in Diagnostic Radiology.” INTERNATIONAL JOURNAL OF RADIATION BIOLOGY 91 (8): 653–63. https://doi.org/10.3109/09553002.2015.1047987.
- Chicago author-date (all authors)
- Vandevoorde, Charlot, Maria Gomolka, Ute Roessler, Daniel Samaga, Carita Lindholm, Maria Fernet, Janet Hall, Eileen Pernot, Houssein El Saghire, Sarah Baatout, Ausrele Kesminiene, and Hubert Thierens. 2015. “EPI-CT: In Vitro Assessment of the Applicability of the γ-H2AX-Foci Assay as Cellular Biomarker for Exposure in a Multicentre Study of Children in Diagnostic Radiology.” INTERNATIONAL JOURNAL OF RADIATION BIOLOGY 91 (8): 653–663. doi:10.3109/09553002.2015.1047987.
- Vancouver
- 1.Vandevoorde C, Gomolka M, Roessler U, Samaga D, Lindholm C, Fernet M, et al. EPI-CT: in vitro assessment of the applicability of the γ-H2AX-foci assay as cellular biomarker for exposure in a multicentre study of children in diagnostic radiology. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY. 2015;91(8):653–63.
- IEEE
- [1]C. Vandevoorde et al., “EPI-CT: in vitro assessment of the applicability of the γ-H2AX-foci assay as cellular biomarker for exposure in a multicentre study of children in diagnostic radiology,” INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, vol. 91, no. 8, pp. 653–663, 2015.
@article{7248000, abstract = {{Purpose : To conduct a feasibility study on the application of the gamma-H2AX foci assay as an exposure biomarker in a prospective multicentre paediatric radiology setting. Materials and methods : A set of in vitro experiments was performed to evaluate technical hurdles related to biological sample collection in a paediatric radiology setting (small blood sample volume), processing and storing of blood samples (effect of storing blood at 4 degrees C), the reliability of foci scoring for low-doses (merge gamma-H2AX/53BP1 scoring), as well as the impact of contrast agent administration as potential confounding factor. Given the exploratory nature of this study and the ethical constraints related to paediatric blood sampling, blood samples from adult volunteers were used for these experiments. In order to test the feasibility of pooling the gamma-H2AX data when different centres are involved in an international multicentre study, two intercomparison studies in the low-dose range (10-500 mGy) were performed. Results : Determination of the number of X-ray induced gamma-H2AX foci is feasible with one 2 ml blood sample pre- and post-computed tomography (CT) scan. Lymphocyte isolation and fixation on slides is necessary within 5 h of blood sampling to guarantee reliable results. The possible enhancement effect of contrast medium on the induction of DNA DSB in a patient study can be ruled out if radiation doses and the contrast agent concentration are within diagnostic ranges. The intercomparison studies using in vitro irradiated blood samples showed that the participating laboratories, executing successfully the gamma-H2AX foci assay in lymphocytes, were able to rank blind samples in order of lowest to highest radiation dose based on mean foci/cell counts. The dose response of all intercomparison data shows that a dose point of 10 mGy could be distinguished from the sham-irradiated control (p = 0.006). Conclusions : The results demonstrate that it is feasible to apply the gamma-H2AX foci assay as a cellular biomarker of exposure in a multicentre prospective study in paediatric CT imaging after validating it in an in vivo international pilot study on paediatric patients.}}, author = {{Vandevoorde, Charlot and Gomolka, Maria and Roessler, Ute and Samaga, Daniel and Lindholm, Carita and Fernet, Maria and Hall, Janet and Pernot, Eileen and El Saghire, Houssein and Baatout, Sarah and Kesminiene, Ausrele and Thierens, Hubert}}, issn = {{0955-3002}}, journal = {{INTERNATIONAL JOURNAL OF RADIATION BIOLOGY}}, keywords = {{molecular radiobiology,low dose eff ects,DNA damage,computed tomography,gamma-H2AX foci,epidemiology,ATOMIC-BOMB SURVIVORS,DOUBLE-STRAND BREAKS,HISTONE H2AX PHOSPHORYLATION,IONIZING-RADIATION EXPOSURE,COMPUTED-TOMOGRAPHY,DNA-DAMAGE,CANCER INCIDENCE,SUBSEQUENT RISK,FOCI,LYMPHOCYTES}}, language = {{eng}}, number = {{8}}, pages = {{653--663}}, title = {{EPI-CT: in vitro assessment of the applicability of the γ-H2AX-foci assay as cellular biomarker for exposure in a multicentre study of children in diagnostic radiology}}, url = {{http://doi.org/10.3109/09553002.2015.1047987}}, volume = {{91}}, year = {{2015}}, }
- Altmetric
- View in Altmetric
- Web of Science
- Times cited: