Advanced search
1 file | 437.11 KB Add to list

CMS RPC commissioning of the existing detector during the long shutdown

Author
Organization
Abstract
February 14th 2013 marked the end of the first period of running of the Large Hadron Collider (LHC) and the start of a two-year break from operation (LS1) aimed at consolidating both the accelerator as well as the detectors. By the end of LS1, the LHC is expected to provide collisions at 13 Tev. While, by 2020, the ultimate instantaneous luminosity is expected to be 10(34)/cm(2)/s. To prepare for this scenario, the Resistive Plate Chamber system at the CMS experiment is planning several detector maintainance and consolidation interventions. These include High Voltage and Low Voltage system reparations, gas leak identification and reparation, signal channel connectivity and functionality. Commissioning and upgrade plans for the existing CMS RPC system are presented here.
Keywords
Particle tracking detectors (Gaseous detectors), Gaseous detectors

Downloads

  • tytgat5.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 437.11 KB

Citation

Please use this url to cite or link to this publication:

MLA
Cimmino, Anna et al. “CMS RPC Commissioning of the Existing Detector During the Long Shutdown.” JOURNAL OF INSTRUMENTATION 9 (2014): n. pag. Print.
APA
Cimmino, A., Ban, Y., Cai, J., Li, Q., Liu, S., Qian, S., Wang, D., et al. (2014). CMS RPC commissioning of the existing detector during the long shutdown. JOURNAL OF INSTRUMENTATION, 9. Presented at the 12th Workshop on Resistive Plate Chambers and Related Detectors.
Chicago author-date
Cimmino, Anna, Y Ban, J Cai, Q Li, S Liu, S Qian, D Wang, et al. 2014. “CMS RPC Commissioning of the Existing Detector During the Long Shutdown.” Journal of Instrumentation 9.
Chicago author-date (all authors)
Cimmino, Anna, Y Ban, J Cai, Q Li, S Liu, S Qian, D Wang, Z Xu, F Zhang, Y Choi, D Kim, J Goh, S Choi, B Hong, JW Kang, M Kang, JH Kwon, KS Lee, SK Lee, SK Park, LM Pant, AK Mohanty, R Chudasama, JB Singh, V Bhatnagar, A Mehta, R Kumar, Simon Cauwenbergh, Silvia Costantini, Shannon Rebecca Crucy, Alexis Fagot, Guillaume Garcia, Alberto Andres Ocampo Rios, Deniz Poyraz, Sinem Salva, Filip Thyssen, Michael Tytgat, Nikolaos Zaganidis, WV Doninck, A Cabrera, L Chaparro, JP Gomez, B Gomez, JC Sanabria, C Avila, A Ahmad, S Muhammad, M Shoaib, H Hoorani, I Awan, I Ali, W Ahmed, MI Asghar, H Shahzad, A Sayed, A Ibrahim, S Aly, Y Assran, A Radi, T Elkafrawy, A Sharma, S Colafranceschi, M Abbrescia, C Calabria, A Colaleo, G Iaselli, F Loddo, M Maggi, S Nuzzo, G Pugliese, R Radogna, R Venditti, P Verwillingen, L Benussi, S Bianco, D Piccolo, P Paolucci, S Buontempo, N Cavallo, M Merola, F Fabozzi, OM Iorio, A Braghieri, P Montagna, C Riccardi, P Salvini, P Vitulo, I Vai, A Magnani, A Dimitrov, L Litov, B Pavlov, P Petkov, A Aleksandrov, V Genchev, P Iaydjiev, M Rodozov, G Sultanov, M Vutova, S Stoykova, R Hadjiiska, HS Ibarguen, MIP Morales, SC Bernardino, I Bagaturia, Z Tsamalaidze, I Crottyt, and MS Kim. 2014. “CMS RPC Commissioning of the Existing Detector During the Long Shutdown.” Journal of Instrumentation 9.
Vancouver
1.
Cimmino A, Ban Y, Cai J, Li Q, Liu S, Qian S, et al. CMS RPC commissioning of the existing detector during the long shutdown. JOURNAL OF INSTRUMENTATION. 2014;9.
IEEE
[1]
A. Cimmino et al., “CMS RPC commissioning of the existing detector during the long shutdown,” JOURNAL OF INSTRUMENTATION, vol. 9, 2014.
@article{6832173,
  abstract     = {February 14th 2013 marked the end of the first period of running of the Large Hadron Collider (LHC) and the start of a two-year break from operation (LS1) aimed at consolidating both the accelerator as well as the detectors. By the end of LS1, the LHC is expected to provide collisions at 13 Tev. While, by 2020, the ultimate instantaneous luminosity is expected to be 10(34)/cm(2)/s. To prepare for this scenario, the Resistive Plate Chamber system at the CMS experiment is planning several detector maintainance and consolidation interventions. These include High Voltage and Low Voltage system reparations, gas leak identification and reparation, signal channel connectivity and functionality. Commissioning and upgrade plans for the existing CMS RPC system are presented here.},
  articleno    = {C10043},
  author       = {Cimmino, Anna and Ban, Y and Cai, J and Li, Q and Liu, S and Qian, S and Wang, D and Xu, Z and Zhang, F and Choi, Y and Kim, D and Goh, J and Choi, S and Hong, B and Kang, JW and Kang, M and Kwon, JH and Lee, KS and Lee, SK and Park, SK and Pant, LM and Mohanty, AK and Chudasama, R and Singh, JB and Bhatnagar, V and Mehta, A and Kumar, R and Cauwenbergh, Simon and Costantini, Silvia and Crucy, Shannon Rebecca and Fagot, Alexis and Garcia, Guillaume and Ocampo Rios, Alberto Andres and Poyraz Lauwers, Deniz and Salva, Sinem and Thyssen, Filip and Tytgat, Michael and Zaganidis, Nikolaos and Doninck, WV and Cabrera, A and Chaparro, L and Gomez, JP and Gomez, B and Sanabria, JC and Avila, C and Ahmad, A and Muhammad, S and Shoaib, M and Hoorani, H and Awan, I and Ali, I and Ahmed, W and Asghar, MI and Shahzad, H and Sayed, A and Ibrahim, A and Aly, S and Assran, Y and Radi, A and Elkafrawy, T and Sharma, A and Colafranceschi, S and Abbrescia, M and Calabria, C and Colaleo, A and Iaselli, G and Loddo, F and Maggi, M and Nuzzo, S and Pugliese, G and Radogna, R and Venditti, R and Verwillingen, P and Benussi, L and Bianco, S and Piccolo, D and Paolucci, P and Buontempo, S and Cavallo, N and Merola, M and Fabozzi, F and Iorio, OM and Braghieri, A and Montagna, P and Riccardi, C and Salvini, P and Vitulo, P and Vai, I and Magnani, A and Dimitrov, A and Litov, L and Pavlov, B and Petkov, P and Aleksandrov, A and Genchev, V and Iaydjiev, P and Rodozov, M and Sultanov, G and Vutova, M and Stoykova, S and Hadjiiska, R and Ibarguen, HS and Morales, MIP and Bernardino, SC and Bagaturia, I and Tsamalaidze, Z and Crottyt, I and Kim, MS},
  issn         = {1748-0221},
  journal      = {JOURNAL OF INSTRUMENTATION},
  keywords     = {Particle tracking detectors (Gaseous detectors),Gaseous detectors},
  language     = {eng},
  location     = {Beijing, PR China},
  pages        = {8},
  title        = {CMS RPC commissioning of the existing detector during the long shutdown},
  url          = {http://dx.doi.org/10.1088/1748-0221/9/10/C10043},
  volume       = {9},
  year         = {2014},
}

Altmetric
View in Altmetric
Web of Science
Times cited: