Advanced search
1 file | 4.38 MB Add to list

Upgrade of the CMS muon system with triple-GEM detectors

Author
Organization
Abstract
The CMS collaboration considers upgrading the muon forward region which is particularly affected by the high-luminosity conditions at the LHC. The proposal involves Gas Electron Multiplier (GEM) chambers, which are able to handle the extreme particle rates expected in this region along with a high spatial resolution. This allows to combine tracking and triggering capabilities, which will improve the CMS muon High Level Trigger, the muon identification and the track reconstruction. Intense R&D has been going on since 2009 and it has lead to the development of several GEM prototypes and associated detector electronics. These GEM prototypes have been subjected to extensive tests in the laboratory and in test beams at the CERN Super Proton Synchrotron (SPS). This contribution will review the status of the CMS upgrade project with GEMs and its impact on the CMS performance.
Keywords
EM, Micropattern gaseous detectors (MSGC, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc), Electron multipliers (gas)

Downloads

  • tytgat4.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 4.38 MB

Citation

Please use this url to cite or link to this publication:

MLA
Abbaneo, D., et al. “Upgrade of the CMS Muon System with Triple-GEM Detectors.” JOURNAL OF INSTRUMENTATION, vol. 9, 2014, doi:10.1088/1748-0221/9/10/C10036.
APA
Abbaneo, D., Abbas, M., Abbrescia, M., Abdelalim, A., Akl, M., Ahmed, W., … Zhang, A. (2014). Upgrade of the CMS muon system with triple-GEM detectors. JOURNAL OF INSTRUMENTATION, 9. https://doi.org/10.1088/1748-0221/9/10/C10036
Chicago author-date
Abbaneo, D, M Abbas, M Abbrescia, AA Abdelalim, MA Akl, W Ahmed, W Ahmed, et al. 2014. “Upgrade of the CMS Muon System with Triple-GEM Detectors.” JOURNAL OF INSTRUMENTATION 9. https://doi.org/10.1088/1748-0221/9/10/C10036.
Chicago author-date (all authors)
Abbaneo, D, M Abbas, M Abbrescia, AA Abdelalim, MA Akl, W Ahmed, W Ahmed, P Altieri, R Aly, A Ashfaq, P Aspell, Y Assran, I Awan, S Bally, Y Ban, S Banerjee, P Barria, L Benussi, V Bhopatkar, S Bianco, J Bos, O Bouhali, S Braibant, S Buontempo, J Cai, C Calabria, C Caputo, F Cassese, A Castaneda, Simon Cauwenbergh, FR Cavallo, A Celik, M Choi, K Choi, S Choi, J Christiansen, Anna Cimmino, S Colafranceschi, A Colaleo, AC Garcia, MM Dabrowski, G De Lentdecker, R De Oliveira, G de Robertis, Sven Dildick, B Dorney, W Elmetenawee, G Fabrice, S Ferry, P Giacomelli, J Gilmore, L Guiducci, A Gutierrez, RM Hadjiiska, A Hassan, J Hauser, K Hoepfner, M Hohlmann, H Hoorani, YG Jeng, T Kamon, PE Karchin, H Kim, S Krutelyov, A Kumar, J Lee, J Lee, T Lenzi, L Litov, F Loddo, T Maerschalk, G Magazzu, M Maggi, Y Maghrbi, A Magnani, N Majumdar, PK Mal, K Mandal, A Marchioro, Andrey Marinov, JA Merlin, N Mohammed, AK Mohanty, A Mohapatra, S Muhammad, S Mukhopadhyay, S Nuzzo, E Oliveri, LM Pant, P Paolucci, I Park, G Passeggio, B Pavlov, B Philipps, M Phipps, D Piccolo, H Postema, G Pugliese, AP Baranac, A Radi, R Radogna, G Raffone, S Ramkrishna, A Ranieri, C Riccardi, A Rodrigues, L Ropelewski, S Roychoddhury, MS Ryu, G Ryu, A Safonov, A Sakharov, Sinem Salva, G Saviano, A Sharma, SK Swain, JP Talvitie, C Tamma, A Tatarinov, N Turini, T Tuuva, J Twigger, Michael Tytgat, I Vai, M van Stenis, R Venditi, E Verhagen, P Verwilligen, P Vitulo, U Yang, Y Yang, R Yonamine, Nikolaos Zaganidis, F Zenoni, and A Zhang. 2014. “Upgrade of the CMS Muon System with Triple-GEM Detectors.” JOURNAL OF INSTRUMENTATION 9. doi:10.1088/1748-0221/9/10/C10036.
Vancouver
1.
Abbaneo D, Abbas M, Abbrescia M, Abdelalim A, Akl M, Ahmed W, et al. Upgrade of the CMS muon system with triple-GEM detectors. JOURNAL OF INSTRUMENTATION. 2014;9.
IEEE
[1]
D. Abbaneo et al., “Upgrade of the CMS muon system with triple-GEM detectors,” JOURNAL OF INSTRUMENTATION, vol. 9, 2014.
@article{6832036,
  abstract     = {{The CMS collaboration considers upgrading the muon forward region which is particularly affected by the high-luminosity conditions at the LHC. The proposal involves Gas Electron Multiplier (GEM) chambers, which are able to handle the extreme particle rates expected in this region along with a high spatial resolution. This allows to combine tracking and triggering capabilities, which will improve the CMS muon High Level Trigger, the muon identification and the track reconstruction. Intense R&D has been going on since 2009 and it has lead to the development of several GEM prototypes and associated detector electronics. These GEM prototypes have been subjected to extensive tests in the laboratory and in test beams at the CERN Super Proton Synchrotron (SPS). This contribution will review the status of the CMS upgrade project with GEMs and its impact on the CMS performance.}},
  articleno    = {{C10036}},
  author       = {{Abbaneo, D and Abbas, M and Abbrescia, M and Abdelalim, AA and Akl, MA and Ahmed, W and Ahmed, W and Altieri, P and Aly, R and Ashfaq, A and Aspell, P and Assran, Y and Awan, I and Bally, S and Ban, Y and Banerjee, S and Barria, P and Benussi, L and Bhopatkar, V and Bianco, S and Bos, J and Bouhali, O and Braibant, S and Buontempo, S and Cai, J and Calabria, C and Caputo, C and Cassese, F and Castaneda, A and Cauwenbergh, Simon and Cavallo, FR and Celik, A and Choi, M and Choi, K and Choi, S and Christiansen, J and Cimmino, Anna and Colafranceschi, S and Colaleo, A and Garcia, AC and Dabrowski, MM and De Lentdecker, G and De Oliveira, R and de Robertis, G and Dildick, Sven and Dorney, B and Elmetenawee, W and Fabrice, G and Ferry, S and Giacomelli, P and Gilmore, J and Guiducci, L and Gutierrez, A and Hadjiiska, RM and Hassan, A and Hauser, J and Hoepfner, K and Hohlmann, M and Hoorani, H and Jeng, YG and Kamon, T and Karchin, PE and Kim, H and Krutelyov, S and Kumar, A and Lee, J and Lee, J and Lenzi, T and Litov, L and Loddo, F and Maerschalk, T and Magazzu, G and Maggi, M and Maghrbi, Y and Magnani, A and Majumdar, N and Mal, PK and Mandal, K and Marchioro, A and Marinov, Andrey and Merlin, JA and Mohammed, N and Mohanty, AK and Mohapatra, A and Muhammad, S and Mukhopadhyay, S and Nuzzo, S and Oliveri, E and Pant, LM and Paolucci, P and Park, I and Passeggio, G and Pavlov, B and Philipps, B and Phipps, M and Piccolo, D and Postema, H and Pugliese, G and Baranac, AP and Radi, A and Radogna, R and Raffone, G and Ramkrishna, S and Ranieri, A and Riccardi, C and Rodrigues, A and Ropelewski, L and Roychoddhury, S and Ryu, MS and Ryu, G and Safonov, A and Sakharov, A and Salva, Sinem and Saviano, G and Sharma, A and Swain, SK and Talvitie, JP and Tamma, C and Tatarinov, A and Turini, N and Tuuva, T and Twigger, J and Tytgat, Michael and Vai, I and van Stenis, M and Venditi, R and Verhagen, E and Verwilligen, P and Vitulo, P and Yang, U and Yang, Y and Yonamine, R and Zaganidis, Nikolaos and Zenoni, F and Zhang, A}},
  issn         = {{1748-0221}},
  journal      = {{JOURNAL OF INSTRUMENTATION}},
  keywords     = {{EM,Micropattern gaseous detectors (MSGC,THGEM,RETHGEM,MHSP,MICROPIC,MICROMEGAS,InGrid,etc),Electron multipliers (gas)}},
  language     = {{eng}},
  location     = {{Novosibirsk, Russia}},
  pages        = {{10}},
  title        = {{Upgrade of the CMS muon system with triple-GEM detectors}},
  url          = {{http://doi.org/10.1088/1748-0221/9/10/C10036}},
  volume       = {{9}},
  year         = {{2014}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: