Advanced search
1 file | 1.24 MB Add to list

CMS RPC muon detector performance with 2010-2012 LHC data

Author
Organization
Project
CMS
Abstract
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers (RPCs) and Drift Tube (DT) chambers in the barrel, RPC and Cathode Strip Chambers (CSCs) in the endcap region. In this paper, the operations and the performance of the RPC system during the first three years of LHC activity are presented. The stability of the RPC performance, in terms of efficiency, cluster size and noise, is also reported. Finally, the radiation background levels on the RPC system have been measured as a function of the LHC luminosity. Extrapolations to the High Luminosity LHC conditions are also discussed.
Keywords
IRRADIATION, Trigger detectors, Resistive-plate chambers

Downloads

  • tytgat2.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 1.24 MB

Citation

Please use this url to cite or link to this publication:

MLA
Pugliese, G et al. “CMS RPC Muon Detector Performance with 2010-2012 LHC Data.” JOURNAL OF INSTRUMENTATION 9 (2014): n. pag. Print.
APA
Pugliese, G., Ban, Y., Cai, J., Li, Q., Liu, S., Qian, S., Wang, D., et al. (2014). CMS RPC muon detector performance with 2010-2012 LHC data. JOURNAL OF INSTRUMENTATION, 9.
Chicago author-date
Pugliese, G, Y Ban, J Cai, Q Li, S Liu, S Qian, D Wang, et al. 2014. “CMS RPC Muon Detector Performance with 2010-2012 LHC Data.” Journal of Instrumentation 9.
Chicago author-date (all authors)
Pugliese, G, Y Ban, J Cai, Q Li, S Liu, S Qian, D Wang, Z Xu, F Zhang, Y Choi, D Kim, J Goh, S Choi, B Hong, JW Kang, M Kang, JH Kwon, KS Lee, SK Lee, SK Park, LM Pant, AK Mohanty, R Chudasama, JB Singh, V Bhatnagar, A Mehta, R Kumar, Simon Cauwenbergh, Silvia Costantini, Anna Cimmino, Shannon Rebecca Crucy, Alexis Fagot, Guillaume Garcia, Alberto Andres Ocampo Rios, Deniz Poyraz, Sinem Salva, Filip Thyssen, Michael Tytgat, Nikolaos Zaganidis, WV Doninck, A Cabrera, L Chaparro, JP Gomez, B Gomez, JC Sanabria, C Avila, A Ahmad, S Muhammad, M Shoaib, H Hoorani, I Awan, I Ali, W Ahmed, MI Asghar, H Shahzad, A Sayed, A Ibrahim, S Aly, Y Assran, A Radi, T Elkafrawy, A Sharma, S Colafranceschi, M Abbrescia, C Calabria, A Colaleo, G Iaselli, F Loddo, M Maggi, S Nuzzo, R Radogna, R Venditti, P Verwillingen, L Benussi, S Bianco, D Piccolo, P Paolucci, S Buontempo, N Cavallo, M Merola, F Fabozzi, OM Iorio, A Braghieri, P Montagna, C Riccardi, P Salvini, P Vitulo, I Vai, A Magnani, A Dimitrov, L Litov, B Pavlov, P Petkov, A Aleksandrov, V Genchev, P Iaydjiev, M Rodozov, G Sultanov, M Vutova, S Stoykova, R Hadjiiska, HS Ibarguen, MIP Morales, SC Bernardino, I Bagaturia, Z Tsamalaidze, I Crotty, and MS Kim. 2014. “CMS RPC Muon Detector Performance with 2010-2012 LHC Data.” Journal of Instrumentation 9.
Vancouver
1.
Pugliese G, Ban Y, Cai J, Li Q, Liu S, Qian S, et al. CMS RPC muon detector performance with 2010-2012 LHC data. JOURNAL OF INSTRUMENTATION. 2014;9.
IEEE
[1]
G. Pugliese et al., “CMS RPC muon detector performance with 2010-2012 LHC data,” JOURNAL OF INSTRUMENTATION, vol. 9, 2014.
@article{6831731,
  abstract     = {The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers (RPCs) and Drift Tube (DT) chambers in the barrel, RPC and Cathode Strip Chambers (CSCs) in the endcap region. In this paper, the operations and the performance of the RPC system during the first three years of LHC activity are presented. The stability of the RPC performance, in terms of efficiency, cluster size and noise, is also reported. Finally, the radiation background levels on the RPC system have been measured as a function of the LHC luminosity. Extrapolations to the High Luminosity LHC conditions are also discussed.},
  articleno    = {C12016},
  author       = {Pugliese, G and Ban, Y and Cai, J and Li, Q and Liu, S and Qian, S and Wang, D and Xu, Z and Zhang, F and Choi, Y and Kim, D and Goh, J and Choi, S and Hong, B and Kang, JW and Kang, M and Kwon, JH and Lee, KS and Lee, SK and Park, SK and Pant, LM and Mohanty, AK and Chudasama, R and Singh, JB and Bhatnagar, V and Mehta, A and Kumar, R and Cauwenbergh, Simon and Costantini, Silvia and Cimmino, Anna and Crucy, Shannon Rebecca and Fagot, Alexis and Garcia, Guillaume and Ocampo Rios, Alberto Andres and Poyraz Lauwers, Deniz and Salva, Sinem and Thyssen, Filip and Tytgat, Michael and Zaganidis, Nikolaos and Doninck, WV and Cabrera, A and Chaparro, L and Gomez, JP and Gomez, B and Sanabria, JC and Avila, C and Ahmad, A and Muhammad, S and Shoaib, M and Hoorani, H and Awan, I and Ali, I and Ahmed, W and Asghar, MI and Shahzad, H and Sayed, A and Ibrahim, A and Aly, S and Assran, Y and Radi, A and Elkafrawy, T and Sharma, A and Colafranceschi, S and Abbrescia, M and Calabria, C and Colaleo, A and Iaselli, G and Loddo, F and Maggi, M and Nuzzo, S and Radogna, R and Venditti, R and Verwillingen, P and Benussi, L and Bianco, S and Piccolo, D and Paolucci, P and Buontempo, S and Cavallo, N and Merola, M and Fabozzi, F and Iorio, OM and Braghieri, A and Montagna, P and Riccardi, C and Salvini, P and Vitulo, P and Vai, I and Magnani, A and Dimitrov, A and Litov, L and Pavlov, B and Petkov, P and Aleksandrov, A and Genchev, V and Iaydjiev, P and Rodozov, M and Sultanov, G and Vutova, M and Stoykova, S and Hadjiiska, R and Ibarguen, HS and Morales, MIP and Bernardino, SC and Bagaturia, I and Tsamalaidze, Z and Crotty, I and Kim, MS},
  issn         = {1748-0221},
  journal      = {JOURNAL OF INSTRUMENTATION},
  keywords     = {IRRADIATION,Trigger detectors,Resistive-plate chambers},
  language     = {eng},
  pages        = {8},
  title        = {CMS RPC muon detector performance with 2010-2012 LHC data},
  url          = {http://dx.doi.org/10.1088/1748-0221/9/12/C12016},
  volume       = {9},
  year         = {2014},
}

Altmetric
View in Altmetric
Web of Science
Times cited: