Advanced search
1 file | 1.16 MB

Performance of the gas gain monitoring system of the CMS RPC muon detector

Author
Organization
Project
CMS
Abstract
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.
Keywords
Gas systems and purification, Muon spectrometers, Materials for gaseous detectors, Particle tracking detectors (Gaseous detectors)

Downloads

  • tytgat1.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 1.16 MB

Citation

Please use this url to cite or link to this publication:

Chicago
Benussi, L, S Bianco, L Passamonti, D Piccolo, D Pierluigi, G Raffone, A Russo, et al. 2015. “Performance of the Gas Gain Monitoring System of the CMS RPC Muon Detector.” Journal of Instrumentation 10.
APA
Benussi, L., Bianco, S., Passamonti, L., Piccolo, D., Pierluigi, D., Raffone, G., Russo, A., et al. (2015). Performance of the gas gain monitoring system of the CMS RPC muon detector. JOURNAL OF INSTRUMENTATION, 10.
Vancouver
1.
Benussi L, Bianco S, Passamonti L, Piccolo D, Pierluigi D, Raffone G, et al. Performance of the gas gain monitoring system of the CMS RPC muon detector. JOURNAL OF INSTRUMENTATION. 2015;10.
MLA
Benussi, L, S Bianco, L Passamonti, et al. “Performance of the Gas Gain Monitoring System of the CMS RPC Muon Detector.” JOURNAL OF INSTRUMENTATION 10 (2015): n. pag. Print.
@article{6831637,
  abstract     = {The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.},
  articleno    = {C01003},
  author       = {Benussi, L and Bianco, S and Passamonti, L and Piccolo, D and Pierluigi, D and Raffone, G and Russo, A and Saviano, G and Ban, Y and Cai, J and Li, Q and Liu, S and Qian, S and Wang, D and Xu, Z and Zhang, F and Choi, Y and Kim, D and Choi, S and Hong, B and Kang, JW and Kang, M and Kwon, JH and Lee, KS and Park, SK and Pant, L and Singh, VBJ and Kumar, AMR and Kumar, S and Chand, S and Singh, A and Bhandari, VK and Cimmino, Anna and Ocampo Rios, Alberto Andres and Thyssen, Filip and Tytgat, Michael and Van Doninck, W and Ahmad, A and Muhammad, S and Shoaib, M and Hoorani, H and Awan, I and Ali, I and Ahmed, W and Asqhar, MI and Shahzad, H and Sayed, A and Ibrahim, A and Assran, Y and Aly, R and Radi, A and Elkafrawi, T and Sharma, A and Colafranceschi, S and Abbrescia, M and Verwilligen, P and Meola, S and Cavallo, N and Braghieri, A and Montagna, P and Riccardi, C and Salvini, P and Vitulo, P and Dimitrov, A and Hadjiiska, R and Litov, L and Pavlov, B and Petkov, P and Aleksandrov, A and Genchev, V and Iaydjiev, P and Rodozov, M and Sultanov, G and Vutova, M and Stoykova, S and Ibarguen, HS and Morales, MIP and Bernardino, SC and Bagaturia, I and Tsamalaidze, Z and Avila, C and Cabrera, A and Chaparro, L and Gomez, JP and Gomez, B and Sanabria, JC and Lee, SK and Mohanty, AK and Thomas, RG and Sehgal, R and Chudasama, R and Sehgal, ST},
  issn         = {1748-0221},
  journal      = {JOURNAL OF INSTRUMENTATION},
  language     = {eng},
  pages        = {8},
  title        = {Performance of the gas gain monitoring system of the CMS RPC muon detector},
  url          = {http://dx.doi.org/10.1088/1748-0221/10/01/C01003},
  volume       = {10},
  year         = {2015},
}

Altmetric
View in Altmetric
Web of Science
Times cited: