Advanced search
1 file | 978.23 KB Add to list

In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: a pilot study using open-MRI

(2014) CLINICAL BIOMECHANICS. 29(8). p.898-905
Author
Organization
Keywords
Kinematics, Polycarbonate-urethane implant, Displacement, TIBIOFEMORAL KINEMATICS, WEIGHT-BEARING, LIVING KNEE, MOVEMENT, OSTEOARTHRITIS, EXTRUSION, FLEXION, MOTION, FEMUR, JOINT, Meniscus, Open MRI

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 978.23 KB

Citation

Please use this url to cite or link to this publication:

MLA
De Coninck, Tineke et al. “In-vivo Evaluation of the Kinematic Behavior of an Artificial Medial Meniscus Implant: a Pilot Study Using open-MRI.” CLINICAL BIOMECHANICS 29.8 (2014): 898–905. Print.
APA
De Coninck, T., Elsner, J. J., Linder-Ganz, E., Cromheecke, M., Shemesh, M., Huysse, W., Verdonk, R., et al. (2014). In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: a pilot study using open-MRI. CLINICAL BIOMECHANICS, 29(8), 898–905.
Chicago author-date
De Coninck, Tineke, Jonahan J Elsner, Eran Linder-Ganz, Michiel Cromheecke, Maoz Shemesh, Wouter Huysse, René Verdonk, Koenraad Verstraete, and Peter Verdonk. 2014. “In-vivo Evaluation of the Kinematic Behavior of an Artificial Medial Meniscus Implant: a Pilot Study Using open-MRI.” Clinical Biomechanics 29 (8): 898–905.
Chicago author-date (all authors)
De Coninck, Tineke, Jonahan J Elsner, Eran Linder-Ganz, Michiel Cromheecke, Maoz Shemesh, Wouter Huysse, René Verdonk, Koenraad Verstraete, and Peter Verdonk. 2014. “In-vivo Evaluation of the Kinematic Behavior of an Artificial Medial Meniscus Implant: a Pilot Study Using open-MRI.” Clinical Biomechanics 29 (8): 898–905.
Vancouver
1.
De Coninck T, Elsner JJ, Linder-Ganz E, Cromheecke M, Shemesh M, Huysse W, et al. In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: a pilot study using open-MRI. CLINICAL BIOMECHANICS. 2014;29(8):898–905.
IEEE
[1]
T. De Coninck et al., “In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: a pilot study using open-MRI,” CLINICAL BIOMECHANICS, vol. 29, no. 8, pp. 898–905, 2014.
@article{5875717,
  author       = {De Coninck, Tineke and Elsner, Jonahan J and Linder-Ganz, Eran and Cromheecke, Michiel and Shemesh, Maoz and Huysse, Wouter and Verdonk, René and Verstraete, Koenraad and Verdonk, Peter},
  issn         = {0268-0033},
  journal      = {CLINICAL BIOMECHANICS},
  keywords     = {Kinematics,Polycarbonate-urethane implant,Displacement,TIBIOFEMORAL KINEMATICS,WEIGHT-BEARING,LIVING KNEE,MOVEMENT,OSTEOARTHRITIS,EXTRUSION,FLEXION,MOTION,FEMUR,JOINT,Meniscus,Open MRI},
  language     = {eng},
  number       = {8},
  pages        = {898--905},
  title        = {In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: a pilot study using open-MRI},
  url          = {http://dx.doi.org/10.1016/j.clinbiomech.2014.07.001},
  volume       = {29},
  year         = {2014},
}

Altmetric
View in Altmetric
Web of Science
Times cited: