The pelvifemoral rhythm in cam-type femoroacetabular impingement

(2014) CLINICAL BIOMECHANICS. 29(1). p.63-67
Author
Organization
Keywords
OSTEOARTHRITIS, RANGE, KINEMATICS, ROTATION, LENGTH, TRACKING DEVICE, MOTION, BILATERAL HIP FLEXION, Kinematics, Range of motion, Pelvifemoral rhythm, Femoroacetabular impingement, Hip, 3-DIMENSIONAL ASSESSMENT

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 485.56 KB

Citation

Please use this url to cite or link to this publication:

MLA
Van Houcke, Jan, et al. “The Pelvifemoral Rhythm in Cam-Type Femoroacetabular Impingement.” CLINICAL BIOMECHANICS, vol. 29, no. 1, 2014, pp. 63–67, doi:10.1016/j.clinbiomech.2013.10.019.
APA
Van Houcke, J., Pattyn, C., Vanden Bossche, L., Redant, C., Maes, J.-W., & Audenaert, E. (2014). The pelvifemoral rhythm in cam-type femoroacetabular impingement. CLINICAL BIOMECHANICS, 29(1), 63–67. https://doi.org/10.1016/j.clinbiomech.2013.10.019
Chicago author-date
Van Houcke, Jan, Christophe Pattyn, Luc Vanden Bossche, Caroline Redant, J-W Maes, and Emmanuel Audenaert. 2014. “The Pelvifemoral Rhythm in Cam-Type Femoroacetabular Impingement.” CLINICAL BIOMECHANICS 29 (1): 63–67. https://doi.org/10.1016/j.clinbiomech.2013.10.019.
Chicago author-date (all authors)
Van Houcke, Jan, Christophe Pattyn, Luc Vanden Bossche, Caroline Redant, J-W Maes, and Emmanuel Audenaert. 2014. “The Pelvifemoral Rhythm in Cam-Type Femoroacetabular Impingement.” CLINICAL BIOMECHANICS 29 (1): 63–67. doi:10.1016/j.clinbiomech.2013.10.019.
Vancouver
1.
Van Houcke J, Pattyn C, Vanden Bossche L, Redant C, Maes J-W, Audenaert E. The pelvifemoral rhythm in cam-type femoroacetabular impingement. CLINICAL BIOMECHANICS. 2014;29(1):63–7.
IEEE
[1]
J. Van Houcke, C. Pattyn, L. Vanden Bossche, C. Redant, J.-W. Maes, and E. Audenaert, “The pelvifemoral rhythm in cam-type femoroacetabular impingement,” CLINICAL BIOMECHANICS, vol. 29, no. 1, pp. 63–67, 2014.
@article{5661626,
  author       = {{Van Houcke, Jan and Pattyn, Christophe and Vanden Bossche, Luc and Redant, Caroline and Maes, J-W and Audenaert, Emmanuel}},
  issn         = {{0268-0033}},
  journal      = {{CLINICAL BIOMECHANICS}},
  keywords     = {{OSTEOARTHRITIS,RANGE,KINEMATICS,ROTATION,LENGTH,TRACKING DEVICE,MOTION,BILATERAL HIP FLEXION,Kinematics,Range of motion,Pelvifemoral rhythm,Femoroacetabular impingement,Hip,3-DIMENSIONAL ASSESSMENT}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{63--67}},
  title        = {{The pelvifemoral rhythm in cam-type femoroacetabular impingement}},
  url          = {{http://doi.org/10.1016/j.clinbiomech.2013.10.019}},
  volume       = {{29}},
  year         = {{2014}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: