A study of film and foil materials for the GEM detector proposed for the CMS muon system upgrade
- Author
- D Abbaneo, M Abbrescia, MA Akl, C Armaingaud, P Aspell, Y Assran, S Bally, Y Ban, S Banerjee, P Barria, L Benussi, V Bhopatkar, S Bianco, J Bos, O Bouhali, J Cai, C Calabria, M Caponero, A Castaneda, Simon Cauwenbergh (UGent) , A Celik, J Christiansen, S Colafranceschi, A Colaleo, AC Garcia, G De Lentdecker, R De Oliveira, G de Robertis, Sven Dildick, M Ferrini, S Ferry, S Ferry, AV Franchi, J Gilmore, A Gutierrez, K Hoepfner, M Hohlmann, T Kamon, PE Karchin, V Khotilovich, S Krutelyov, F Loddo, T Maerschalk, G Magazzu, M Maggi, Y Maghrbi, A Marchioro, Andrey Marinov (UGent) , N Majumdar, JA Merlin, S Mukhopadhyay, S Nuzzo, E Oliveri, L Passamonti, B Philipps, D Piccolo, D Pierluigi, H Postema, A Radi, R Radogna, G Raffone, A Ranieri, A Rodrigues, L Ropelewski, A Russo, A Safonov, A Sakharov, Sinem Salva (UGent) , G Saviano, A Sharma, A Tatarinov, H Teng, N Turini, J Twigger, Michael Tytgat (UGent) , M Van Stenis, E Verhagen, M Valente, Y Yang, Nikolaos Zaganidis (UGent) and F Zenonig
- Organization
- Abstract
- During the next shutdown of the LHC at CERN, the CMS experiment plans to start installing GEM detectors in the endcap (high pseudorapidity) region. These muon detectors have excellent spatial and temporal resolution as well as a high chemical stability and radiation hardness. A report is given on preliminary results of materials studies that aimed to fully characterize the GEM detector components before and after the exposure to a high-radiation environment.
- Keywords
- Manufacturing, Detection of defects, Materials for gaseous detectors, Muon spectrometers
Downloads
-
mt1.pdf
- full text
- |
- open access
- |
- |
- 953.47 KB
Citation
Please use this url to cite or link to this publication: http://hdl.handle.net/1854/LU-5333363
- MLA
- Abbaneo, D., et al. “A Study of Film and Foil Materials for the GEM Detector Proposed for the CMS Muon System Upgrade.” JOURNAL OF INSTRUMENTATION, vol. 9, 2014, doi:10.1088/1748-0221/9/04/C04022.
- APA
- Abbaneo, D., Abbrescia, M., Akl, M., Armaingaud, C., Aspell, P., Assran, Y., … Zenonig, F. (2014). A study of film and foil materials for the GEM detector proposed for the CMS muon system upgrade. JOURNAL OF INSTRUMENTATION, 9. https://doi.org/10.1088/1748-0221/9/04/C04022
- Chicago author-date
- Abbaneo, D, M Abbrescia, MA Akl, C Armaingaud, P Aspell, Y Assran, S Bally, et al. 2014. “A Study of Film and Foil Materials for the GEM Detector Proposed for the CMS Muon System Upgrade.” JOURNAL OF INSTRUMENTATION 9. https://doi.org/10.1088/1748-0221/9/04/C04022.
- Chicago author-date (all authors)
- Abbaneo, D, M Abbrescia, MA Akl, C Armaingaud, P Aspell, Y Assran, S Bally, Y Ban, S Banerjee, P Barria, L Benussi, V Bhopatkar, S Bianco, J Bos, O Bouhali, J Cai, C Calabria, M Caponero, A Castaneda, Simon Cauwenbergh, A Celik, J Christiansen, S Colafranceschi, A Colaleo, AC Garcia, G De Lentdecker, R De Oliveira, G de Robertis, Sven Dildick, M Ferrini, S Ferry, S Ferry, AV Franchi, J Gilmore, A Gutierrez, K Hoepfner, M Hohlmann, T Kamon, PE Karchin, V Khotilovich, S Krutelyov, F Loddo, T Maerschalk, G Magazzu, M Maggi, Y Maghrbi, A Marchioro, Andrey Marinov, N Majumdar, JA Merlin, S Mukhopadhyay, S Nuzzo, E Oliveri, L Passamonti, B Philipps, D Piccolo, D Pierluigi, H Postema, A Radi, R Radogna, G Raffone, A Ranieri, A Rodrigues, L Ropelewski, A Russo, A Safonov, A Sakharov, Sinem Salva, G Saviano, A Sharma, A Tatarinov, H Teng, N Turini, J Twigger, Michael Tytgat, M Van Stenis, E Verhagen, M Valente, Y Yang, Nikolaos Zaganidis, and F Zenonig. 2014. “A Study of Film and Foil Materials for the GEM Detector Proposed for the CMS Muon System Upgrade.” JOURNAL OF INSTRUMENTATION 9. doi:10.1088/1748-0221/9/04/C04022.
- Vancouver
- 1.Abbaneo D, Abbrescia M, Akl M, Armaingaud C, Aspell P, Assran Y, et al. A study of film and foil materials for the GEM detector proposed for the CMS muon system upgrade. JOURNAL OF INSTRUMENTATION. 2014;9.
- IEEE
- [1]D. Abbaneo et al., “A study of film and foil materials for the GEM detector proposed for the CMS muon system upgrade,” JOURNAL OF INSTRUMENTATION, vol. 9, 2014.
@article{5333363, abstract = {{During the next shutdown of the LHC at CERN, the CMS experiment plans to start installing GEM detectors in the endcap (high pseudorapidity) region. These muon detectors have excellent spatial and temporal resolution as well as a high chemical stability and radiation hardness. A report is given on preliminary results of materials studies that aimed to fully characterize the GEM detector components before and after the exposure to a high-radiation environment.}}, articleno = {{C04022}}, author = {{Abbaneo, D and Abbrescia, M and Akl, MA and Armaingaud, C and Aspell, P and Assran, Y and Bally, S and Ban, Y and Banerjee, S and Barria, P and Benussi, L and Bhopatkar, V and Bianco, S and Bos, J and Bouhali, O and Cai, J and Calabria, C and Caponero, M and Castaneda, A and Cauwenbergh, Simon and Celik, A and Christiansen, J and Colafranceschi, S and Colaleo, A and Garcia, AC and De Lentdecker, G and De Oliveira, R and de Robertis, G and Dildick, Sven and Ferrini, M and Ferry, S and Ferry, S and Franchi, AV and Gilmore, J and Gutierrez, A and Hoepfner, K and Hohlmann, M and Kamon, T and Karchin, PE and Khotilovich, V and Krutelyov, S and Loddo, F and Maerschalk, T and Magazzu, G and Maggi, M and Maghrbi, Y and Marchioro, A and Marinov, Andrey and Majumdar, N and Merlin, JA and Mukhopadhyay, S and Nuzzo, S and Oliveri, E and Passamonti, L and Philipps, B and Piccolo, D and Pierluigi, D and Postema, H and Radi, A and Radogna, R and Raffone, G and Ranieri, A and Rodrigues, A and Ropelewski, L and Russo, A and Safonov, A and Sakharov, A and Salva, Sinem and Saviano, G and Sharma, A and Tatarinov, A and Teng, H and Turini, N and Twigger, J and Tytgat, Michael and Van Stenis, M and Verhagen, E and Valente, M and Yang, Y and Zaganidis, Nikolaos and Zenonig, F}}, issn = {{1748-0221}}, journal = {{JOURNAL OF INSTRUMENTATION}}, keywords = {{Manufacturing,Detection of defects,Materials for gaseous detectors,Muon spectrometers}}, language = {{eng}}, location = {{Siena, Italy}}, pages = {{8}}, title = {{A study of film and foil materials for the GEM detector proposed for the CMS muon system upgrade}}, url = {{http://doi.org/10.1088/1748-0221/9/04/C04022}}, volume = {{9}}, year = {{2014}}, }
- Altmetric
- View in Altmetric
- Web of Science
- Times cited: