Field test facility for the development of a reference method for ventilation rate and emission measurements in naturally ventilated pig houses
- Author
- Gerlinde De Vogeleer (UGent) , Jan Pieters (UGent) , Philippe Van Overbeke (UGent) and Peter Demeyer
- Organization
- Abstract
- A test facility for field measurements of natural ventilation in livestock buildings was developed. Choice of used materials and methods were taken into account: ultrasonic wind anemometers, linear guiding systems for sensor movement and data loggers were carefully chosen. The true scale test facility makes it possible to measure and study air flows and related characteristics for long periods, under real conditions of natural ventilation.
- Keywords
- neural networks, ultrasonic sensor, natural ventilation, test facility
Downloads
-
2013-24.pdf
- full text
- |
- open access
- |
- |
- 394.81 KB
Citation
Please use this url to cite or link to this publication: http://hdl.handle.net/1854/LU-4210910
- MLA
- De Vogeleer, Gerlinde, et al. “Field Test Facility for the Development of a Reference Method for Ventilation Rate and Emission Measurements in Naturally Ventilated Pig Houses.” 11. Tagung: Bau, Technik Und Umwelt in Der Landwirtschaftlichen Nutztierhaltung = 11th Conference Construction, Engineering and Environment in Livestock Farming, Kuratorium für Technik und Bauwesen in der Landwirtschaft, 2013, pp. 258–63.
- APA
- De Vogeleer, G., Pieters, J., Van Overbeke, P., & Demeyer, P. (2013). Field test facility for the development of a reference method for ventilation rate and emission measurements in naturally ventilated pig houses. 11. Tagung: Bau, Technik Und Umwelt in Der Landwirtschaftlichen Nutztierhaltung = 11th Conference Construction, Engineering and Environment in Livestock Farming, 258–263. Darmstadt, Germany: Kuratorium für Technik und Bauwesen in der Landwirtschaft.
- Chicago author-date
- De Vogeleer, Gerlinde, Jan Pieters, Philippe Van Overbeke, and Peter Demeyer. 2013. “Field Test Facility for the Development of a Reference Method for Ventilation Rate and Emission Measurements in Naturally Ventilated Pig Houses.” In 11. Tagung: Bau, Technik Und Umwelt in Der Landwirtschaftlichen Nutztierhaltung = 11th Conference Construction, Engineering and Environment in Livestock Farming, 258–63. Darmstadt, Germany: Kuratorium für Technik und Bauwesen in der Landwirtschaft.
- Chicago author-date (all authors)
- De Vogeleer, Gerlinde, Jan Pieters, Philippe Van Overbeke, and Peter Demeyer. 2013. “Field Test Facility for the Development of a Reference Method for Ventilation Rate and Emission Measurements in Naturally Ventilated Pig Houses.” In 11. Tagung: Bau, Technik Und Umwelt in Der Landwirtschaftlichen Nutztierhaltung = 11th Conference Construction, Engineering and Environment in Livestock Farming, 258–263. Darmstadt, Germany: Kuratorium für Technik und Bauwesen in der Landwirtschaft.
- Vancouver
- 1.De Vogeleer G, Pieters J, Van Overbeke P, Demeyer P. Field test facility for the development of a reference method for ventilation rate and emission measurements in naturally ventilated pig houses. In: 11 Tagung: Bau, Technik und Umwelt in der landwirtschaftlichen Nutztierhaltung = 11th Conference construction, engineering and environment in livestock farming. Darmstadt, Germany: Kuratorium für Technik und Bauwesen in der Landwirtschaft; 2013. p. 258–63.
- IEEE
- [1]G. De Vogeleer, J. Pieters, P. Van Overbeke, and P. Demeyer, “Field test facility for the development of a reference method for ventilation rate and emission measurements in naturally ventilated pig houses,” in 11. Tagung: Bau, Technik und Umwelt in der landwirtschaftlichen Nutztierhaltung = 11th Conference construction, engineering and environment in livestock farming, Vechta, Germany, 2013, pp. 258–263.
@inproceedings{4210910, abstract = {{A test facility for field measurements of natural ventilation in livestock buildings was developed. Choice of used materials and methods were taken into account: ultrasonic wind anemometers, linear guiding systems for sensor movement and data loggers were carefully chosen. The true scale test facility makes it possible to measure and study air flows and related characteristics for long periods, under real conditions of natural ventilation.}}, author = {{De Vogeleer, Gerlinde and Pieters, Jan and Van Overbeke, Philippe and Demeyer, Peter}}, booktitle = {{11. Tagung: Bau, Technik und Umwelt in der landwirtschaftlichen Nutztierhaltung = 11th Conference construction, engineering and environment in livestock farming}}, isbn = {{9783941583801}}, keywords = {{neural networks,ultrasonic sensor,natural ventilation,test facility}}, language = {{eng}}, location = {{Vechta, Germany}}, pages = {{258--263}}, publisher = {{Kuratorium für Technik und Bauwesen in der Landwirtschaft}}, title = {{Field test facility for the development of a reference method for ventilation rate and emission measurements in naturally ventilated pig houses}}, year = {{2013}}, }