Advanced search
2 files | 2.34 MB Add to list

Thermo-mechanical analysis of an underground car park structure exposed to fire

(2013) FIRE SAFETY JOURNAL. 57. p.96-106
Author
Organization
Keywords
CFD, Punching shear, FE analysis, Global structural analysis, Fire, Flat concrete slabs, REINFORCED-CONCRETE SLABS

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 2.18 MB
  • manuscript.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 158.97 KB

Citation

Please use this url to cite or link to this publication:

MLA
Annerel, Emmanuel, et al. “Thermo-Mechanical Analysis of an Underground Car Park Structure Exposed to Fire.” FIRE SAFETY JOURNAL, vol. 57, 2013, pp. 96–106, doi:10.1016/j.firesaf.2012.07.006.
APA
Annerel, E., Taerwe, L., Merci, B., Jansen, D., Bamonte, P., & Felicetti, R. (2013). Thermo-mechanical analysis of an underground car park structure exposed to fire. FIRE SAFETY JOURNAL, 57, 96–106. https://doi.org/10.1016/j.firesaf.2012.07.006
Chicago author-date
Annerel, Emmanuel, Luc Taerwe, Bart Merci, D Jansen, P Bamonte, and R Felicetti. 2013. “Thermo-Mechanical Analysis of an Underground Car Park Structure Exposed to Fire.” FIRE SAFETY JOURNAL 57: 96–106. https://doi.org/10.1016/j.firesaf.2012.07.006.
Chicago author-date (all authors)
Annerel, Emmanuel, Luc Taerwe, Bart Merci, D Jansen, P Bamonte, and R Felicetti. 2013. “Thermo-Mechanical Analysis of an Underground Car Park Structure Exposed to Fire.” FIRE SAFETY JOURNAL 57: 96–106. doi:10.1016/j.firesaf.2012.07.006.
Vancouver
1.
Annerel E, Taerwe L, Merci B, Jansen D, Bamonte P, Felicetti R. Thermo-mechanical analysis of an underground car park structure exposed to fire. FIRE SAFETY JOURNAL. 2013;57:96–106.
IEEE
[1]
E. Annerel, L. Taerwe, B. Merci, D. Jansen, P. Bamonte, and R. Felicetti, “Thermo-mechanical analysis of an underground car park structure exposed to fire,” FIRE SAFETY JOURNAL, vol. 57, pp. 96–106, 2013.
@article{4096379,
  author       = {{Annerel, Emmanuel and Taerwe, Luc and Merci, Bart and Jansen, D and Bamonte, P and Felicetti, R}},
  issn         = {{0379-7112}},
  journal      = {{FIRE SAFETY JOURNAL}},
  keywords     = {{CFD,Punching shear,FE analysis,Global structural analysis,Fire,Flat concrete slabs,REINFORCED-CONCRETE SLABS}},
  language     = {{eng}},
  pages        = {{96--106}},
  title        = {{Thermo-mechanical analysis of an underground car park structure exposed to fire}},
  url          = {{http://doi.org/10.1016/j.firesaf.2012.07.006}},
  volume       = {{57}},
  year         = {{2013}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: