Experimental assessment of polyphonic tones with cochlear implants

Richard Penninger (UGent) , Charles Limb, KATRIEN VERMEIRE (UGent) , Marc Leman (UGent) and Ingeborg Dhooge (UGent)
(2013) OTOLOGY & NEUROTOLOGY. 34(7). p.1267-1271
Author
Organization
Project
EBRAMUS (Europe, Brain and Music: New perspectives for stimulating cognitive and sensory processes)
Abstract
Hypothesis: We hypothesized that cochlear implant (CI) users are able to discriminate tones consisting of 1 and 2 modulation frequencies when the stimuli are applied through direct electrical stimulation. Background: Music perception is a very challenging task for CI users. In music, multiple tones often occur simultaneously, an essential feature of harmony. Proper encoding of simultaneous tones is crucial to musical perception and appreciation. With current implant processing strategies, CI users are severely impaired in the perception of pitch and polyphony. Methods: The ability of CI users to identify the number of simultaneous tones was assessed. Stimuli were applied with direct electrical stimulation. Stimuli with 1 modulation frequency were applied on a basal, a middle, and an apical electrode to determine if there was an effect of cochlear region. Stimuli with 2 modulation frequencies were applied on combinations of an apical electrode together with a basal or a middle electrode. Additionally, 2 modulations frequencies were presented at the same time on an apical electrode only. Results: Results demonstrate that subjects were generally able to identify the number of modulation frequencies in the presented stimuli. Performance for 1 modulation frequency stimuli was significantly above chance level on all 3 electrodes tested. Performance was best on the apical and the middle electrode, followed by the basal electrode. Subjects were also able to identify 2 modulation frequencies significantly above chance level on all 3 combinations tested. Performance was best on combination apical-basal followed by apical-middle. Performance was worst when 2 modulation frequencies were applied on an apical electrode only, but it was still significantly above chance level. Conclusion: If sound processing strategies were to use concurrent modulation frequencies on multiple or single electrodes, then possibly polyphonic tones would be better perceived by CI users yielding better music and language perception.
Keywords
PITCH PERCEPTS, Cochlear implants, Polyphonic pitch perception, Temporal pitch, Pitch perception

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 359.70 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Penninger, Richard, Charles Limb, KATRIEN VERMEIRE, Marc Leman, and Ingeborg Dhooge. 2013. “Experimental Assessment of Polyphonic Tones with Cochlear Implants.” Otology & Neurotology 34 (7): 1267–1271.
APA
Penninger, R., Limb, C., VERMEIRE, K., Leman, M., & Dhooge, I. (2013). Experimental assessment of polyphonic tones with cochlear implants. OTOLOGY & NEUROTOLOGY, 34(7), 1267–1271.
Vancouver
1.
Penninger R, Limb C, VERMEIRE K, Leman M, Dhooge I. Experimental assessment of polyphonic tones with cochlear implants. OTOLOGY & NEUROTOLOGY. 2013;34(7):1267–71.
MLA
Penninger, Richard, Charles Limb, KATRIEN VERMEIRE, et al. “Experimental Assessment of Polyphonic Tones with Cochlear Implants.” OTOLOGY & NEUROTOLOGY 34.7 (2013): 1267–1271. Print.
@article{3218293,
  abstract     = {Hypothesis: We hypothesized that cochlear implant (CI) users are able to discriminate tones consisting of 1 and 2 modulation frequencies when the stimuli are applied through direct electrical stimulation.
Background: Music perception is a very challenging task for CI users. In music, multiple tones often occur simultaneously, an essential feature of harmony. Proper encoding of simultaneous tones is crucial to musical perception and appreciation. With current implant processing strategies, CI users are severely impaired in the perception of pitch and polyphony.
Methods: The ability of CI users to identify the number of simultaneous tones was assessed. Stimuli were applied with direct electrical stimulation. Stimuli with 1 modulation frequency were applied on a basal, a middle, and an apical electrode to determine if there was an effect of cochlear region. Stimuli with 2 modulation frequencies were applied on combinations of an apical electrode together with a basal or a middle electrode. Additionally, 2 modulations frequencies were presented at the same time on an apical electrode only.
Results: Results demonstrate that subjects were generally able to identify the number of modulation frequencies in the presented stimuli. Performance for 1 modulation frequency stimuli was significantly above chance level on all 3 electrodes tested. Performance was best on the apical and the middle electrode, followed by the basal electrode. Subjects were also able to identify 2 modulation frequencies significantly above chance level on all 3 combinations tested. Performance was best on combination apical-basal followed by apical-middle. Performance was worst when 2 modulation frequencies were applied on an apical electrode only, but it was still significantly above chance level.
Conclusion: If sound processing strategies were to use concurrent modulation frequencies on multiple or single electrodes, then possibly polyphonic tones would be better perceived by CI users yielding better music and language perception.},
  author       = {Penninger, Richard and Limb, Charles and VERMEIRE, KATRIEN and Leman, Marc and Dhooge, Ingeborg},
  issn         = {1531-7129},
  journal      = {OTOLOGY \& NEUROTOLOGY},
  keyword      = {PITCH PERCEPTS,Cochlear implants,Polyphonic pitch perception,Temporal pitch,Pitch perception},
  language     = {eng},
  number       = {7},
  pages        = {1267--1271},
  title        = {Experimental assessment of polyphonic tones with cochlear implants},
  volume       = {34},
  year         = {2013},
}

Web of Science
Times cited: