Ghent University Academic Bibliography

Advanced

Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil

Michel Struys UGent, Hugo Vereecke, ANNELIESE MOERMAN, EW JENSEN, DAVID VERHAEGHEN, NIKOLAAS DE NEVE, Frank Dumortier and Eric Mortier UGent (2003) ANESTHESIOLOGY. 99(4). p.802-812
Please use this url to cite or link to this publication:
author
organization
year
type
journalArticle
publication status
published
subject
journal title
ANESTHESIOLOGY
Anesthesiology
volume
99
issue
4
pages
802-812 pages
publisher
LIPPINCOTT WILLIAMS & WILKINS
Web of Science type
Article
Web of Science id
000185573500008
JCR category
ANESTHESIOLOGY
JCR impact factor
3.503 (2003)
JCR rank
2/22 (2003)
JCR quartile
1 (2003)
ISSN
0003-3022
language
English
UGent publication?
yes
classification
A1
id
218709
handle
http://hdl.handle.net/1854/LU-218709
date created
2004-05-18 14:26:00
date last changed
2008-02-23 12:04:02
@article{218709,
  author       = {Struys, Michel and Vereecke, Hugo and MOERMAN, ANNELIESE and JENSEN, EW and VERHAEGHEN, DAVID and DE NEVE, NIKOLAAS and Dumortier, Frank and Mortier, Eric},
  issn         = {0003-3022},
  journal      = {ANESTHESIOLOGY},
  language     = {eng},
  number       = {4},
  pages        = {802--812},
  publisher    = {LIPPINCOTT WILLIAMS \& WILKINS},
  title        = {Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil},
  volume       = {99},
  year         = {2003},
}

Chicago
Struys, Michel, Hugo Vereecke, ANNELIESE MOERMAN, EW JENSEN, DAVID VERHAEGHEN, NIKOLAAS DE NEVE, Frank Dumortier, and Eric Mortier. 2003. “Ability of the Bispectral Index, Autoregressive Modelling with Exogenous Input-derived Auditory Evoked Potentials, and Predicted Propofol Concentrations to Measure Patient Responsiveness During Anesthesia with Propofol and Remifentanil.” Anesthesiology 99 (4): 802–812.
APA
Struys, M., Vereecke, H., MOERMAN, A., JENSEN, E., VERHAEGHEN, D., DE NEVE, N., Dumortier, F., et al. (2003). Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil. ANESTHESIOLOGY, 99(4), 802–812.
Vancouver
1.
Struys M, Vereecke H, MOERMAN A, JENSEN E, VERHAEGHEN D, DE NEVE N, et al. Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil. ANESTHESIOLOGY. LIPPINCOTT WILLIAMS & WILKINS; 2003;99(4):802–12.
MLA
Struys, Michel, Hugo Vereecke, ANNELIESE MOERMAN, et al. “Ability of the Bispectral Index, Autoregressive Modelling with Exogenous Input-derived Auditory Evoked Potentials, and Predicted Propofol Concentrations to Measure Patient Responsiveness During Anesthesia with Propofol and Remifentanil.” ANESTHESIOLOGY 99.4 (2003): 802–812. Print.