Advanced search
1 file | 999.58 KB

Investigations into the reliability of SAR-OSL equivalent doses obtained for quartz samples displaying dose response curves with more than one component

(2012) RADIATION MEASUREMENTS. 47(9). p.740-745
Author
Organization
Keywords
OPTICALLY STIMULATED LUMINESCENCE, CHINESE LOESS PLATEAU, SAND-SIZED QUARTZ, GROWTH-CURVE, CHRONOLOGY, ROMANIA, RESOLUTION, DOSIMETER, FELDSPAR, PROTOCOL, Quartz, OSL, Dose response, Saturation characteristics

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 999.58 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Timar-Gabor, Alida, Stefan Vasiliniuc, Dimitri Vandenberghe, C Cosma, and AG Wintle. 2012. “Investigations into the Reliability of SAR-OSL Equivalent Doses Obtained for Quartz Samples Displaying Dose Response Curves with More Than One Component.” Radiation Measurements 47 (9): 740–745.
APA
Timar-Gabor, A., Vasiliniuc, S., Vandenberghe, D., Cosma, C., & Wintle, A. (2012). Investigations into the reliability of SAR-OSL equivalent doses obtained for quartz samples displaying dose response curves with more than one component. RADIATION MEASUREMENTS, 47(9), 740–745.
Vancouver
1.
Timar-Gabor A, Vasiliniuc S, Vandenberghe D, Cosma C, Wintle A. Investigations into the reliability of SAR-OSL equivalent doses obtained for quartz samples displaying dose response curves with more than one component. RADIATION MEASUREMENTS. 2012;47(9):740–5.
MLA
Timar-Gabor, Alida, Stefan Vasiliniuc, Dimitri Vandenberghe, et al. “Investigations into the Reliability of SAR-OSL Equivalent Doses Obtained for Quartz Samples Displaying Dose Response Curves with More Than One Component.” RADIATION MEASUREMENTS 47.9 (2012): 740–745. Print.
@article{2083043,
  author       = {Timar-Gabor, Alida and Vasiliniuc, Stefan and Vandenberghe, Dimitri and Cosma, C and Wintle, AG},
  issn         = {1350-4487},
  journal      = {RADIATION MEASUREMENTS},
  keyword      = {OPTICALLY STIMULATED LUMINESCENCE,CHINESE LOESS PLATEAU,SAND-SIZED QUARTZ,GROWTH-CURVE,CHRONOLOGY,ROMANIA,RESOLUTION,DOSIMETER,FELDSPAR,PROTOCOL,Quartz,OSL,Dose response,Saturation characteristics},
  language     = {eng},
  number       = {9},
  pages        = {740--745},
  title        = {Investigations into the reliability of SAR-OSL equivalent doses obtained for quartz samples displaying dose response curves with more than one component},
  url          = {http://dx.doi.org/10.1016/j.radmeas.2011.12.001},
  volume       = {47},
  year         = {2012},
}

Altmetric
View in Altmetric
Web of Science
Times cited: