Abstract
Pulse wave velocity (PWV) has proven to be an important parameter in diagnosing certain diseases, as well as predicting their outcomes. For PWV measurement the segmentation of MRI images of abdomen and four pairs of modulus-encoded and velocity-encoded images is required. We propose in this work a set of robust segmentation methods based on our segmentation using projections method and shortest path calculation.

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 92.91 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Babin, Danilo, Aleksandra Pizurica, and Wilfried Philips. 2011. “Robust Segmentation Methods for Aortic Pulse Wave Velocity Measurement.” In IEEE EMBS Benelux Chapter, Annual Symposium, Abstracts. IEEE Engineering in Medicine and Biology Society (EMBS). Benelux Chapter.
APA
Babin, D., Pizurica, A., & Philips, W. (2011). Robust segmentation methods for aortic pulse wave velocity measurement. IEEE EMBS Benelux Chapter, Annual symposium, Abstracts. Presented at the 2011 Annual symposium of the IEEE EMBS Benelux Chapter, IEEE Engineering in Medicine and Biology Society (EMBS). Benelux Chapter.
Vancouver
1.
Babin D, Pizurica A, Philips W. Robust segmentation methods for aortic pulse wave velocity measurement. IEEE EMBS Benelux Chapter, Annual symposium, Abstracts. IEEE Engineering in Medicine and Biology Society (EMBS). Benelux Chapter; 2011.
MLA
Babin, Danilo, Aleksandra Pizurica, and Wilfried Philips. “Robust Segmentation Methods for Aortic Pulse Wave Velocity Measurement.” IEEE EMBS Benelux Chapter, Annual Symposium, Abstracts. IEEE Engineering in Medicine and Biology Society (EMBS). Benelux Chapter, 2011. Print.
@inproceedings{1999117,
  abstract     = {Pulse wave velocity (PWV) has proven to be an important parameter in diagnosing certain diseases, as well as predicting their outcomes. For PWV measurement the segmentation of MRI images of abdomen and four pairs of modulus-encoded and velocity-encoded images is required. We propose in this work a set of robust segmentation methods based on our segmentation using projections method and shortest path calculation.},
  author       = {Babin, Danilo and Pizurica, Aleksandra and Philips, Wilfried},
  booktitle    = {IEEE EMBS Benelux Chapter, Annual symposium, Abstracts},
  language     = {eng},
  location     = {Leuven, Belgium},
  publisher    = {IEEE Engineering in Medicine and Biology Society (EMBS). Benelux Chapter},
  title        = {Robust segmentation methods for aortic pulse wave velocity measurement},
  year         = {2011},
}