Analytical characteristics of an inductively coupled plasma mass spectrometer coupled with a thermospray nebulization system

Author
Organization
Abstract
The analytical characteristics of a thermospray sample introduction system coupled to an inductively coupled plasma mass spectrometer have been evaluated, The results obtained with the thermospray system were compared with those obtained with two other arrangements, namely the pneumatic nebulizer coupled with a spray chamber (the conventional arrangement) and the same pneumatic nebulizer coupled with the desolvating unit employed with the thermospray nebulizer, In the presence of salts of Na (NaNO3) or Ca[Ca(NO3)(2)], the non-spectroscopic interferences (analyte ion signal suppression) were more pronounced in the thermospray system than in the conventional arrangement, whereas in the presence of mineral acids (H2SO4, H3PO4) both systems gave similar suppressions. The apparent analyte element concentrations due to spectral overlap with MO(x)(+) (e,g,, SO+, SO2+, PO+, PO2+, CaO+) or ArM(+) (e.g, ArNa+, ArS+, ArP+) were lower or similar for the thermospray nebulizer in comparison with those obtained with the conventional arrangement, In order to reduce memory effects, a sample Bow injection system was used for the analysis of three candidate environmental reference materials [Community Bureau of Reference (BCR) Certified Reference Materials 141R Soil-calcareous loam, 144R Sewage sludge - domestic and 146R Sewage sludge - industrial]. The accuracy and precision of external calibration with internal standardization, standard additions and isotope dilution were compared, Similar results were obtained for the aqua regia soluble content of Cd and Pb in these materials.
Keywords
THERMOSPRAY NEBULIZATION, INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY, MEMORY EFFECTS, SPECTROSCOPIC AND NONSPECTROSCOPIC INTERFERENCES, CALIBRATION METHODS, ANALYSIS OF ENVIRONMENTAL SAMPLES, ATOMIC EMISSION-SPECTROMETRY, DIRECT-INJECTION NEBULIZATION, SAMPLE INTRODUCTION SYSTEM, ELEMENTAL SPECIATION, CHROMATOGRAPHY, INTERFERENCES

Citation

Please use this url to cite or link to this publication:

MLA
Vanhoe, Hans, et al. “Analytical Characteristics of an Inductively Coupled Plasma Mass Spectrometer Coupled with a Thermospray Nebulization System.” JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, vol. 10, no. 9, 1995, pp. 575–81, doi:10.1039/ja9951000575.
APA
Vanhoe, H., Saverwijns, S., Parent, M., Moens, L., & Dams, R. (1995). Analytical characteristics of an inductively coupled plasma mass spectrometer coupled with a thermospray nebulization system. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 10(9), 575–581. https://doi.org/10.1039/ja9951000575
Chicago author-date
Vanhoe, Hans, Steven Saverwijns, Magali Parent, Luc Moens, and Richard Dams. 1995. “Analytical Characteristics of an Inductively Coupled Plasma Mass Spectrometer Coupled with a Thermospray Nebulization System.” JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY 10 (9): 575–81. https://doi.org/10.1039/ja9951000575.
Chicago author-date (all authors)
Vanhoe, Hans, Steven Saverwijns, Magali Parent, Luc Moens, and Richard Dams. 1995. “Analytical Characteristics of an Inductively Coupled Plasma Mass Spectrometer Coupled with a Thermospray Nebulization System.” JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY 10 (9): 575–581. doi:10.1039/ja9951000575.
Vancouver
1.
Vanhoe H, Saverwijns S, Parent M, Moens L, Dams R. Analytical characteristics of an inductively coupled plasma mass spectrometer coupled with a thermospray nebulization system. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY. 1995;10(9):575–81.
IEEE
[1]
H. Vanhoe, S. Saverwijns, M. Parent, L. Moens, and R. Dams, “Analytical characteristics of an inductively coupled plasma mass spectrometer coupled with a thermospray nebulization system,” JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, vol. 10, no. 9, pp. 575–581, 1995.
@article{195361,
  abstract     = {{The analytical characteristics of a thermospray sample introduction system coupled to an inductively coupled plasma mass spectrometer have been evaluated, The results obtained with the thermospray system were compared with those obtained with two other arrangements, namely the pneumatic nebulizer coupled with a spray chamber (the conventional arrangement) and the same pneumatic nebulizer coupled with the desolvating unit employed with the thermospray nebulizer, In the presence of salts of Na (NaNO3) or Ca[Ca(NO3)(2)], the non-spectroscopic interferences (analyte ion signal suppression) were more pronounced in the thermospray system than in the conventional arrangement, whereas in the presence of mineral acids (H2SO4, H3PO4) both systems gave similar suppressions. The apparent analyte element concentrations due to spectral overlap with MO(x)(+) (e,g,, SO+, SO2+, PO+, PO2+, CaO+) or ArM(+) (e.g, ArNa+, ArS+, ArP+) were lower or similar for the thermospray nebulizer in comparison with those obtained with the conventional arrangement, In order to reduce memory effects, a sample Bow injection system was used for the analysis of three candidate environmental reference materials [Community Bureau of Reference (BCR) Certified Reference Materials 141R Soil-calcareous loam, 144R Sewage sludge - domestic and 146R Sewage sludge - industrial]. The accuracy and precision of external calibration with internal standardization, standard additions and isotope dilution were compared, Similar results were obtained for the aqua regia soluble content of Cd and Pb in these materials.}},
  author       = {{Vanhoe, Hans and Saverwijns, Steven and Parent, Magali and Moens, Luc and Dams, Richard}},
  issn         = {{0267-9477}},
  journal      = {{JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY}},
  keywords     = {{THERMOSPRAY NEBULIZATION,INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY,MEMORY EFFECTS,SPECTROSCOPIC AND NONSPECTROSCOPIC INTERFERENCES,CALIBRATION METHODS,ANALYSIS OF ENVIRONMENTAL SAMPLES,ATOMIC EMISSION-SPECTROMETRY,DIRECT-INJECTION NEBULIZATION,SAMPLE INTRODUCTION SYSTEM,ELEMENTAL SPECIATION,CHROMATOGRAPHY,INTERFERENCES}},
  language     = {{eng}},
  number       = {{9}},
  pages        = {{575--581}},
  title        = {{Analytical characteristics of an inductively coupled plasma mass spectrometer coupled with a thermospray nebulization system}},
  url          = {{http://dx.doi.org/10.1039/ja9951000575}},
  volume       = {{10}},
  year         = {{1995}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: