A three-detector positron lifetime setup suited for measurements on irradiated steels

Author
Organization
Abstract
An advanced positron lifetime setup is described, particularly suited to perform measurements on irradiated nuclear reactor pressure vessel steel. The equipment exists of three BaF2-detectors operated in triple coincidence mode to avoid the very disturbing Co-60-contribution in the lifetime spectra. The use of BaF2 scintillators gives rise to an acceptable efficiency and a time resolution well below 300 ps.
Keywords
SCINTILLATORS

Citation

Please use this url to cite or link to this publication:

Chicago
Van Hoorebeke, Luc, A Fabry, E van Walle, J Van de Velde, Danny Segers, and L Dorikens-Vanpraet. 1996. “A Three-detector Positron Lifetime Setup Suited for Measurements on Irradiated Steels.” Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment 371 (3): 566–571.
APA
Van Hoorebeke, L., Fabry, A., van Walle, E., Van de Velde, J., Segers, D., & Dorikens-Vanpraet, L. (1996). A three-detector positron lifetime setup suited for measurements on irradiated steels. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 371(3), 566–571.
Vancouver
1.
Van Hoorebeke L, Fabry A, van Walle E, Van de Velde J, Segers D, Dorikens-Vanpraet L. A three-detector positron lifetime setup suited for measurements on irradiated steels. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. 1996;371(3):566–71.
MLA
Van Hoorebeke, Luc, A Fabry, E van Walle, et al. “A Three-detector Positron Lifetime Setup Suited for Measurements on Irradiated Steels.” NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 371.3 (1996): 566–571. Print.
@article{187860,
  abstract     = {An advanced positron lifetime setup is described, particularly suited to perform measurements on irradiated nuclear reactor pressure vessel steel. The equipment exists of three BaF2-detectors operated in triple coincidence mode to avoid the very disturbing Co-60-contribution in the lifetime spectra. The use of BaF2 scintillators gives rise to an acceptable efficiency and a time resolution well below 300 ps.},
  author       = {Van Hoorebeke, Luc and Fabry, A and van Walle, E and Van de Velde, J and Segers, Danny and Dorikens-Vanpraet, L},
  issn         = {0168-9002},
  journal      = {NUCLEAR INSTRUMENTS \& METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT},
  keyword      = {SCINTILLATORS},
  language     = {eng},
  number       = {3},
  pages        = {566--571},
  title        = {A three-detector positron lifetime setup suited for measurements on irradiated steels},
  url          = {http://dx.doi.org/10.1016/0168-9002(95)01007-6},
  volume       = {371},
  year         = {1996},
}

Altmetric
View in Altmetric