Effectiveness of cerclage according to severity of cervical length shortening: a meta-analysis
- Author
- V Berghella, SM Keeler, MS To, SIETSKE ALTHUISIUS (UGent) and OA Rust
- Organization
- Keywords
- PREVENTION, transvaginal ultrasound, TRANSVAGINAL ULTRASOUND, TRIAL, WOMEN, cervical length, preterm birth, cerclage
Downloads
-
(...).pdf
- full text
- |
- UGent only
- |
- |
- 86.47 KB
Citation
Please use this url to cite or link to this publication: http://hdl.handle.net/1854/LU-1845310
- MLA
- Berghella, V., et al. “Effectiveness of Cerclage According to Severity of Cervical Length Shortening: A Meta-Analysis.” ULTRASOUND IN OBSTETRICS & GYNECOLOGY, vol. 35, no. 4, 2010, pp. 468–73, doi:10.1002/uog.7547.
- APA
- Berghella, V., Keeler, S., To, M., ALTHUISIUS, S., & Rust, O. (2010). Effectiveness of cerclage according to severity of cervical length shortening: a meta-analysis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 35(4), 468–473. https://doi.org/10.1002/uog.7547
- Chicago author-date
- Berghella, V, SM Keeler, MS To, SIETSKE ALTHUISIUS, and OA Rust. 2010. “Effectiveness of Cerclage According to Severity of Cervical Length Shortening: A Meta-Analysis.” ULTRASOUND IN OBSTETRICS & GYNECOLOGY 35 (4): 468–73. https://doi.org/10.1002/uog.7547.
- Chicago author-date (all authors)
- Berghella, V, SM Keeler, MS To, SIETSKE ALTHUISIUS, and OA Rust. 2010. “Effectiveness of Cerclage According to Severity of Cervical Length Shortening: A Meta-Analysis.” ULTRASOUND IN OBSTETRICS & GYNECOLOGY 35 (4): 468–473. doi:10.1002/uog.7547.
- Vancouver
- 1.Berghella V, Keeler S, To M, ALTHUISIUS S, Rust O. Effectiveness of cerclage according to severity of cervical length shortening: a meta-analysis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY. 2010;35(4):468–73.
- IEEE
- [1]V. Berghella, S. Keeler, M. To, S. ALTHUISIUS, and O. Rust, “Effectiveness of cerclage according to severity of cervical length shortening: a meta-analysis,” ULTRASOUND IN OBSTETRICS & GYNECOLOGY, vol. 35, no. 4, pp. 468–473, 2010.
@article{1845310, author = {{Berghella, V and Keeler, SM and To, MS and ALTHUISIUS, SIETSKE and Rust, OA}}, issn = {{0960-7692}}, journal = {{ULTRASOUND IN OBSTETRICS & GYNECOLOGY}}, keywords = {{PREVENTION,transvaginal ultrasound,TRANSVAGINAL ULTRASOUND,TRIAL,WOMEN,cervical length,preterm birth,cerclage}}, language = {{eng}}, number = {{4}}, pages = {{468--473}}, title = {{Effectiveness of cerclage according to severity of cervical length shortening: a meta-analysis}}, url = {{http://doi.org/10.1002/uog.7547}}, volume = {{35}}, year = {{2010}}, }
- Altmetric
- View in Altmetric
- Web of Science
- Times cited: