Ghent University Academic Bibliography

Advanced

The C-13-octanoic acid breath test: validation of a new noninvasive method of measuring gastric emptying in rats.

Renaat Schoonjans, Bruno Van Vlem, N VAN HEDDEGHEM, W VANDAMME, Raymond Vanholder UGent, Norbert Lameire, Romain Lefebvre UGent and MARTINE DE VOS UGent (2002) NEUROGASTROENTEROLOGY AND MOTILITY. 14(3). p.287-293
Please use this url to cite or link to this publication:
author
organization
year
type
journalArticle
publication status
published
subject
journal title
NEUROGASTROENTEROLOGY AND MOTILITY
Neurogastroenterol. Motil.
volume
14
issue
3
pages
287-293 pages
Web of Science type
Article
Web of Science id
000176222100010
JCR category
CLINICAL NEUROLOGY
JCR impact factor
2.083 (2002)
JCR rank
45/137 (2002)
JCR quartile
2 (2002)
ISSN
1350-1925
language
English
UGent publication?
yes
classification
A1
id
164933
handle
http://hdl.handle.net/1854/LU-164933
date created
2004-01-14 13:40:00
date last changed
2008-02-22 22:47:51
@article{164933,
  author       = {Schoonjans, Renaat and Van Vlem, Bruno and VAN HEDDEGHEM, N and VANDAMME, W and Vanholder, Raymond and Lameire, Norbert and Lefebvre, Romain and DE VOS, MARTINE},
  issn         = {1350-1925},
  journal      = {NEUROGASTROENTEROLOGY AND MOTILITY},
  language     = {eng},
  number       = {3},
  pages        = {287--293},
  title        = {The C-13-octanoic acid breath test: validation of a new noninvasive method of measuring gastric emptying in rats.},
  volume       = {14},
  year         = {2002},
}

Chicago
Schoonjans, Renaat, Bruno Van Vlem, N VAN HEDDEGHEM, W VANDAMME, Raymond Vanholder, Norbert Lameire, Romain Lefebvre, and MARTINE DE VOS. 2002. “The C-13-octanoic Acid Breath Test: Validation of a New Noninvasive Method of Measuring Gastric Emptying in Rats.” Neurogastroenterology and Motility 14 (3): 287–293.
APA
Schoonjans, Renaat, Van Vlem, B., VAN HEDDEGHEM, N., VANDAMME, W., Vanholder, R., Lameire, N., Lefebvre, R., et al. (2002). The C-13-octanoic acid breath test: validation of a new noninvasive method of measuring gastric emptying in rats. NEUROGASTROENTEROLOGY AND MOTILITY, 14(3), 287–293.
Vancouver
1.
Schoonjans R, Van Vlem B, VAN HEDDEGHEM N, VANDAMME W, Vanholder R, Lameire N, et al. The C-13-octanoic acid breath test: validation of a new noninvasive method of measuring gastric emptying in rats. NEUROGASTROENTEROLOGY AND MOTILITY. 2002;14(3):287–93.
MLA
Schoonjans, Renaat, Bruno Van Vlem, N VAN HEDDEGHEM, et al. “The C-13-octanoic Acid Breath Test: Validation of a New Noninvasive Method of Measuring Gastric Emptying in Rats.” NEUROGASTROENTEROLOGY AND MOTILITY 14.3 (2002): 287–293. Print.