Performance of glass resistive plate chambers for a high-granularity semi-digital calorimeter

Author
Organization
Abstract
A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold semi-digital read-out. Several GRPC prototypes with their electronics have been successfully built and tested in pion beams. The design of these detectors is presented along with the test results on efficiency, pad multiplicity, stability and reproducibility.
Keywords
Calorimeters, Gaseous detectors, Resistive-plate chambers, Calorimeter methods

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 1.83 MB

Citation

Please use this url to cite or link to this publication:

MLA
Bedjidian, M, K Belkadhi, V Boudry, et al. “Performance of Glass Resistive Plate Chambers for a High-granularity Semi-digital Calorimeter.” JOURNAL OF INSTRUMENTATION 6 (2011): n. pag. Print.
APA
Bedjidian, M., Belkadhi, K., Boudry, V., Combaret, C., Decotigny, D., Gil, E. C., de la Taille, C., et al. (2011). Performance of glass resistive plate chambers for a high-granularity semi-digital calorimeter. JOURNAL OF INSTRUMENTATION, 6.
Chicago author-date
Bedjidian, M, K Belkadhi, V Boudry, C Combaret, D Decotigny, E Cortina Gil, C de la Taille, et al. 2011. “Performance of Glass Resistive Plate Chambers for a High-granularity Semi-digital Calorimeter.” Journal of Instrumentation 6.
Chicago author-date (all authors)
Bedjidian, M, K Belkadhi, V Boudry, C Combaret, D Decotigny, E Cortina Gil, C de la Taille, R Dellanegra, VA Gapienko, G Grenier, C Jauffret, R Kieffer, MC Fouz, R Han, I Laktineh, N Lumb, K Manai, S Mannai, H Mathez, L Mirabito, JP Pelayo, M Ruan, F Schirra, N Seguin-Moreau, W Tromeur, Michael Tytgat, M Vander Donckt, and Nikolaos Zaganidis. 2011. “Performance of Glass Resistive Plate Chambers for a High-granularity Semi-digital Calorimeter.” Journal of Instrumentation 6.
Vancouver
1.
Bedjidian M, Belkadhi K, Boudry V, Combaret C, Decotigny D, Gil EC, et al. Performance of glass resistive plate chambers for a high-granularity semi-digital calorimeter. JOURNAL OF INSTRUMENTATION. 2011;6.
IEEE
[1]
M. Bedjidian et al., “Performance of glass resistive plate chambers for a high-granularity semi-digital calorimeter,” JOURNAL OF INSTRUMENTATION, vol. 6, 2011.
@article{1318979,
  abstract     = {A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold semi-digital read-out. Several GRPC prototypes with their electronics have been successfully built and tested in pion beams. The design of these detectors is presented along with the test results on efficiency, pad multiplicity, stability and reproducibility.},
  articleno    = {P02001},
  author       = {Bedjidian, M and Belkadhi, K and Boudry, V and Combaret, C and Decotigny, D and Gil, E Cortina and de la Taille, C and Dellanegra, R and Gapienko, VA and Grenier, G and Jauffret, C and Kieffer, R and Fouz, MC and Han, R and Laktineh, I and Lumb, N and Manai, K and Mannai, S and Mathez, H and Mirabito, L and Pelayo, JP and Ruan, M and Schirra, F and Seguin-Moreau, N and Tromeur, W and Tytgat, Michael and Vander Donckt, M and Zaganidis, Nikolaos},
  issn         = {1748-0221},
  journal      = {JOURNAL OF INSTRUMENTATION},
  keywords     = {Calorimeters,Gaseous detectors,Resistive-plate chambers,Calorimeter methods},
  language     = {eng},
  pages        = {15},
  title        = {Performance of glass resistive plate chambers for a high-granularity semi-digital calorimeter},
  url          = {http://dx.doi.org/10.1088/1748-0221/6/02/P02001},
  volume       = {6},
  year         = {2011},
}