Monte Carlo-based reconstruction for positron emission tomography

Long Zhang UGent (2011)
abstract
The poor spatial resolution of Positron emission tomography (PET) images has limited the application of this imaging modality into some expanding fields, e.g. treatment planning, therapeutic evaluation and Cardiac imaging. The spatial resolution degradation is attributed to the non-perfect data acquisition. Therefore, an accurate modeling of the data acquisition process could be employed to improve the physical performance of a PET scanner. We investigated a Monte Carlo-based method to model these effects. The calculation and storage of the system model are challenging through the Monte Carlo method due to the huge dimension of the system matrix. To address this issue, we developed a framework of techniques. The first component is a set of simple variance reduction techniques for resolution modeling based on egs_pet (an EGSnrc user code). These variance reduction techniques improved the simulation efficiency by a factor of about 15. The second component is symmetry handling for a cylindrical PET scanner, which improves both the simulation efficiency and the storage requirement by a factor up to 406. The last component is a rotator-based reconstruction algorithm, which performs reconstruction with the pre-computed system matrix. Our system matrix simulation took five days on 50 cores of Xeon 2.66 GHz CPU. The system matrix took about 1.8 GB of memory when we limited the maximum ring difference to 14. The contrast noise trade-offs were significantly improved compared to a line-length system model with a Siddon projector pair. Experiment-based point spread function (PSF) modeling was also investigated. The PSFs were measured on a sparse grid covering a small portion of the entire field of view (FOV). The rest part could be obtained by symmetry. A parameterization technique was employed to estimate the PSFs at unmeasured locations. The system model was further downsized by employing a factorized matrix approach, where the full system model is expressed as a product of a projection space blurring component and a geometrical component. The obtained system model is about 250 MB. The contrast noise trade-off was significantly improved compared to a line-length system model with a Siddon projector pair. The PSF model was found to be superior to the Monte Carlo model in both contrast recovery and noise reduction. In addition, we also investigated the ringing artifacts, which were detected in image reconstruction with both the Monte Carlo model and the PSF model. We evaluated the ringing artifacts with three different system models: an under-compensated model, an over-compensated model and a matched model. These models characterized the impact of “taper artifacts” on the ringing artifacts. We used “taper artifacts” to represent the artifacts caused by the partial volume effect. Data at different noise levels were produced to evaluate the impact of noise artifacts on the ringing artifacts. The ringing artifacts were found to be sensitive to the width of the system model and nearly independent of the data noise. The ringing artifacts were demonstrated to be a secondary effect compared to the noise artifacts and taper artifacts, however, the ringing artifacts were inherent in PET imaging with resolution compensation. We also noticed that moderately over-compensated the resolution loss may yield slightly over-estimated resolution and contrast, particularly for small hot lesions. These characteristics could be beneficial in diagnosis or treatment planning. Finally, we have demonstrated that resolution compensation is an efficient way in improving image quality of PET. The improvements are two folds (i) the improved resolution, which yields sharper images and uniform resolution across the FOV; (ii) the improved contrast, which improves the quantification of both hot and cold lesions. Our studies also indicate that the PSF model is more preferred than the Monte Carlo model.
Please use this url to cite or link to this publication:
author
promoter
UGent and UGent
organization
alternative title
Monte Carlo-gebaseerde reconstructie voor positron emissie tomografie
year
type
dissertation (monograph)
subject
keyword
Image reconstruction, Point spread function, Resolution modeling, Ringing artifacts
pages
XXXIII, 163 pages
publisher
Ghent University. Faculty of Engineering and Architecture
place of publication
Ghent, Belgium
defense location
Gent : Faculteit Ingenieurswetenschappen en Architectuur (Jozef Plateauzaal)
defense date
2011-04-08 17:30
ISBN
9789085784180
language
English
UGent publication?
yes
classification
D1
additional info
dissertation in part contains copyrighted material
copyright statement
I have transferred the copyright for this publication to the publisher
id
1208336
handle
http://hdl.handle.net/1854/LU-1208336
date created
2011-04-13 15:10:15
date last changed
2011-04-14 08:53:35
@phdthesis{1208336,
  abstract     = {The poor spatial resolution of Positron emission tomography (PET) images has limited the application of this imaging modality into some expanding fields, e.g. treatment planning, therapeutic evaluation and Cardiac imaging. The spatial resolution degradation is attributed to the non-perfect data acquisition. Therefore, an accurate modeling of the data acquisition process could be employed to improve the physical performance of a PET scanner. 
We investigated a Monte Carlo-based method to model these effects. The calculation and storage of the system model are challenging through the Monte Carlo method due to the huge dimension of the system matrix.
To address this issue, we developed a framework of techniques. The first component is a set of simple variance reduction techniques for resolution modeling based on egs\_pet (an EGSnrc user code).  These variance reduction techniques improved the simulation efficiency by a factor of about 15. The second component is symmetry handling for a cylindrical PET scanner, which improves both the simulation efficiency and the storage requirement by a factor up to 406. The last component is a rotator-based reconstruction algorithm, which performs reconstruction with the pre-computed system matrix. Our system matrix simulation took five days on 50 cores of Xeon 2.66 GHz CPU. The system matrix took about 1.8 GB of memory when we limited the maximum ring difference to 14. The contrast noise trade-offs were significantly improved compared to a line-length system model with a Siddon projector pair.
Experiment-based point spread function (PSF) modeling was also investigated. The PSFs were measured on a sparse grid covering a small portion of the entire field of view (FOV). The rest part could be obtained by symmetry. A parameterization technique was employed to estimate the PSFs at unmeasured locations. The system model was further downsized by employing a factorized matrix approach, where the full system model is expressed as a product of a projection space blurring component and a geometrical component. The obtained system model is about 250 MB. The contrast noise trade-off was significantly improved compared to a line-length system model with a Siddon projector pair. The PSF model was found to be superior to the Monte Carlo model in both contrast recovery and noise reduction.
In addition, we also investigated the ringing artifacts, which were detected in image reconstruction with both the Monte Carlo model and the PSF model. We evaluated the ringing artifacts with three different system models: an under-compensated model, an over-compensated model and a matched model. These models characterized the impact of {\textquotedblleft}taper artifacts{\textquotedblright} on the ringing artifacts. We used {\textquotedblleft}taper artifacts{\textquotedblright} to represent the artifacts caused by the partial volume effect. Data at different noise levels were produced to evaluate the impact of noise artifacts on the ringing artifacts. The ringing artifacts were found to be sensitive to the width of the system model and nearly independent of the data noise. The ringing artifacts were demonstrated to be a secondary effect compared to the noise artifacts and taper artifacts, however, the ringing artifacts were inherent in PET imaging with resolution compensation. We also noticed that moderately over-compensated the resolution loss may yield slightly over-estimated resolution and contrast, particularly for small hot lesions. These characteristics could be beneficial in diagnosis or treatment planning. 
Finally, we have demonstrated that resolution compensation is an efficient way in improving image quality of PET. The improvements are two folds (i) the improved resolution, which yields sharper images and uniform resolution across the FOV; (ii) the improved contrast, which improves the quantification of both hot and cold lesions. Our studies also indicate that the PSF model is more preferred than the Monte Carlo model.},
  author       = {Zhang, Long},
  isbn         = {9789085784180},
  keyword      = {Image reconstruction,Point spread function,Resolution modeling,Ringing artifacts},
  language     = {eng},
  pages        = {XXXIII, 163},
  publisher    = {Ghent University. Faculty of Engineering and Architecture},
  school       = {Ghent University},
  title        = {Monte Carlo-based reconstruction for positron emission tomography},
  year         = {2011},
}

Chicago
Zhang, Long. 2011. “Monte Carlo-based Reconstruction for Positron Emission Tomography”. Ghent, Belgium: Ghent University. Faculty of Engineering and Architecture.
APA
Zhang, Long. (2011). Monte Carlo-based reconstruction for positron emission tomography. Ghent University. Faculty of Engineering and Architecture, Ghent, Belgium.
Vancouver
1.
Zhang L. Monte Carlo-based reconstruction for positron emission tomography. [Ghent, Belgium]: Ghent University. Faculty of Engineering and Architecture; 2011.
MLA
Zhang, Long. “Monte Carlo-based Reconstruction for Positron Emission Tomography.” 2011 : n. pag. Print.