Clinical validation of intensity modulated arc therapy (IMAT) by means of polymer gel dosimetry

Wim Duthoy, Koen Vergote, Werner De Gersem UGent, Yves De Deene UGent, Carlos De Wagter UGent and Wilfried De Neve UGent (2004) JOURNAL OF PHYSICS CONFERENCE SERIES. 3. p.276-279
Please use this url to cite or link to this publication:
author
organization
year
type
conference
publication status
published
subject
in
JOURNAL OF PHYSICS CONFERENCE SERIES
J. Phys. Conf. Ser.
editor
Yves De Deene UGent and Clive Baldock
volume
3
issue title
Third international conference on radiotherapy gel dosimetry
pages
276 - 279
publisher
IOP Publishing
place of publication
Bristol, UK
conference name
3rd International conference on Radiotherapy Gel Dosimetry (DOSGEL 2004)
conference location
Ghent, Belgium
conference start
2004-09-13
conference end
2004-09-16
ISSN
1742-6588
DOI
10.1088/1742-6596/3/1/046
language
English
UGent publication?
yes
classification
C1
copyright statement
I have transferred the copyright for this publication to the publisher
id
1184220
handle
http://hdl.handle.net/1854/LU-1184220
date created
2011-03-09 00:55:47
date last changed
2017-01-02 09:52:26
@inproceedings{1184220,
  author       = {Duthoy, Wim and Vergote, Koen and De Gersem, Werner and De Deene, Yves and De Wagter, Carlos and De Neve, Wilfried},
  booktitle    = {JOURNAL OF PHYSICS CONFERENCE SERIES},
  editor       = {De Deene, Yves and Baldock, Clive},
  issn         = {1742-6588},
  language     = {eng},
  location     = {Ghent, Belgium},
  pages        = {276--279},
  publisher    = {IOP Publishing},
  title        = {Clinical validation of intensity modulated arc therapy (IMAT) by means of polymer gel dosimetry},
  url          = {http://dx.doi.org/10.1088/1742-6596/3/1/046},
  volume       = {3},
  year         = {2004},
}

Chicago
Duthoy, Wim, Koen Vergote, Werner De Gersem, Yves De Deene, Carlos De Wagter, and Wilfried De Neve. 2004. “Clinical Validation of Intensity Modulated Arc Therapy (IMAT) by Means of Polymer Gel Dosimetry.” In Journal of Physics Conference Series, ed. Yves De Deene and Clive Baldock, 3:276–279. Bristol, UK: IOP Publishing.
APA
Duthoy, Wim, Vergote, K., De Gersem, W., De Deene, Y., De Wagter, C., & De Neve, W. (2004). Clinical validation of intensity modulated arc therapy (IMAT) by means of polymer gel dosimetry. In Yves De Deene & C. Baldock (Eds.), JOURNAL OF PHYSICS CONFERENCE SERIES (Vol. 3, pp. 276–279). Presented at the 3rd International conference on Radiotherapy Gel Dosimetry (DOSGEL 2004), Bristol, UK: IOP Publishing.
Vancouver
1.
Duthoy W, Vergote K, De Gersem W, De Deene Y, De Wagter C, De Neve W. Clinical validation of intensity modulated arc therapy (IMAT) by means of polymer gel dosimetry. In: De Deene Y, Baldock C, editors. JOURNAL OF PHYSICS CONFERENCE SERIES. Bristol, UK: IOP Publishing; 2004. p. 276–9.
MLA
Duthoy, Wim, Koen Vergote, Werner De Gersem, et al. “Clinical Validation of Intensity Modulated Arc Therapy (IMAT) by Means of Polymer Gel Dosimetry.” Journal of Physics Conference Series. Ed. Yves De Deene & Clive Baldock. Vol. 3. Bristol, UK: IOP Publishing, 2004. 276–279. Print.