Ghent University Academic Bibliography

Advanced

Monte Carlo calculations of dose distributions around 32P and 198Au stents for intravascular brachytherapy

Nick Reynaert, F Verhaegen, Yvo Taeymans, Marc Van Eijkeren UGent and Hubert Thierens UGent (1999) MEDICAL PHYSICS. 26(8). p.1484-1491
Please use this url to cite or link to this publication:
author
organization
alternative title
Monte Carlo calculations of dose distributions around P-32 and (198)AU stents for intravascular brachytherapy
year
type
journalArticle (original)
publication status
published
subject
keyword
intravascular brachytherapy, stents, Monte Carlo calculations, NEOINTIMA FORMATION, CELL-PROLIFERATION, CORONARY-ARTERIES, RADIATION-THERAPY, RESTENOSIS, HYPERPLASIA, IRRADIATION, PREVENTION, MANAGEMENT, INJURY
journal title
MEDICAL PHYSICS
Med. Phys.
volume
26
issue
8
pages
1484 - 1491
Web of Science type
Article
Web of Science id
000082121600007
ISSN
0094-2405
DOI
10.1118/1.598644
language
English
UGent publication?
yes
classification
A1
id
116457
handle
http://hdl.handle.net/1854/LU-116457
date created
2004-01-14 13:35:00
date last changed
2017-01-31 13:46:21
@article{116457,
  author       = {Reynaert, Nick and Verhaegen, F and Taeymans, Yvo and Van Eijkeren, Marc and Thierens, Hubert},
  issn         = {0094-2405},
  journal      = {MEDICAL PHYSICS},
  keyword      = {intravascular brachytherapy,stents,Monte Carlo calculations,NEOINTIMA FORMATION,CELL-PROLIFERATION,CORONARY-ARTERIES,RADIATION-THERAPY,RESTENOSIS,HYPERPLASIA,IRRADIATION,PREVENTION,MANAGEMENT,INJURY},
  language     = {eng},
  number       = {8},
  pages        = {1484--1491},
  title        = {Monte Carlo calculations of dose distributions around 32P and 198Au stents for intravascular brachytherapy},
  url          = {http://dx.doi.org/10.1118/1.598644},
  volume       = {26},
  year         = {1999},
}

Chicago
Reynaert, Nick, F Verhaegen, Yvo Taeymans, Marc Van Eijkeren, and Hubert Thierens. 1999. “Monte Carlo Calculations of Dose Distributions Around 32P and 198Au Stents for Intravascular Brachytherapy.” Medical Physics 26 (8): 1484–1491.
APA
Reynaert, N., Verhaegen, F., Taeymans, Y., Van Eijkeren, M., & Thierens, H. (1999). Monte Carlo calculations of dose distributions around 32P and 198Au stents for intravascular brachytherapy. MEDICAL PHYSICS, 26(8), 1484–1491.
Vancouver
1.
Reynaert N, Verhaegen F, Taeymans Y, Van Eijkeren M, Thierens H. Monte Carlo calculations of dose distributions around 32P and 198Au stents for intravascular brachytherapy. MEDICAL PHYSICS. 1999;26(8):1484–91.
MLA
Reynaert, Nick, F Verhaegen, Yvo Taeymans, et al. “Monte Carlo Calculations of Dose Distributions Around 32P and 198Au Stents for Intravascular Brachytherapy.” MEDICAL PHYSICS 26.8 (1999): 1484–1491. Print.