Advanced search
2 files | 2.65 MB

Sensitivity analysis of CFD coupled non-isothermal heat and moisture modelling

Marnix Van Belleghem (UGent) , Hendrik-Jan Steeman (UGent) , Marijke Steeman (UGent) , Arnold Janssens (UGent) and Michel De Paepe (UGent)
(2010) BUILDING AND ENVIRONMENT. 45(11). p.2485-2496
Author
Organization
Keywords
Sensitivity, Non-isothermal, Modelling, Heat and moisture transport, CEO, INDOOR AIR, HYSTERESIS, HUMIDITY, SIMULATION

Downloads

  • M.V.Bellegh.Sensitivity.pdf
    • full text
    • |
    • open access
    • |
    • PDF
    • |
    • 699.09 KB
  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 1.95 MB

Citation

Please use this url to cite or link to this publication:

Chicago
Van Belleghem, Marnix, Hendrik-Jan Steeman, Marijke Steeman, Arnold Janssens, and Michel De Paepe. 2010. “Sensitivity Analysis of CFD Coupled Non-isothermal Heat and Moisture Modelling.” Building and Environment 45 (11): 2485–2496.
APA
Van Belleghem, M., Steeman, H.-J., Steeman, M., Janssens, A., & De Paepe, M. (2010). Sensitivity analysis of CFD coupled non-isothermal heat and moisture modelling. BUILDING AND ENVIRONMENT, 45(11), 2485–2496.
Vancouver
1.
Van Belleghem M, Steeman H-J, Steeman M, Janssens A, De Paepe M. Sensitivity analysis of CFD coupled non-isothermal heat and moisture modelling. BUILDING AND ENVIRONMENT. 2010;45(11):2485–96.
MLA
Van Belleghem, Marnix, Hendrik-Jan Steeman, Marijke Steeman, et al. “Sensitivity Analysis of CFD Coupled Non-isothermal Heat and Moisture Modelling.” BUILDING AND ENVIRONMENT 45.11 (2010): 2485–2496. Print.
@article{1095336,
  author       = {Van Belleghem, Marnix and Steeman, Hendrik-Jan and Steeman, Marijke and Janssens, Arnold and De Paepe, Michel},
  issn         = {0360-1323},
  journal      = {BUILDING AND ENVIRONMENT},
  keyword      = {Sensitivity,Non-isothermal,Modelling,Heat and moisture transport,CEO,INDOOR AIR,HYSTERESIS,HUMIDITY,SIMULATION},
  language     = {eng},
  number       = {11},
  pages        = {2485--2496},
  title        = {Sensitivity analysis of CFD coupled non-isothermal heat and moisture modelling},
  url          = {http://dx.doi.org/10.1016/j.buildenv.2010.05.011},
  volume       = {45},
  year         = {2010},
}

Altmetric
View in Altmetric
Web of Science
Times cited: