Ghent University Academic Bibliography

Advanced

Spatially resolved 3D micro-XANES by a confocal detection scheme

Geert Silversmit UGent, Bart Vekemans UGent, Sergey Nikitenko, Sylvia Schmitz, Tom Schoonjans UGent, Frank E Brenker and Laszlo Vincze UGent (2010) PHYSICAL CHEMISTRY CHEMICAL PHYSICS. 12(21). p.5653-5659
abstract
A confocal setup based on polycapillary half-lenses was used to demonstrate three-dimensional (3D) spatially resolved µ-XANES in fluorescence detection mode at the DUBBLE XAS station of the ESRF (BM26A). The incoming beam was focused using a polycapillary half-lens and a second glass polycapillary was placed in front of the energy dispersive detector to establish the confocal detection. The full-width-half-maxima along the main axes of the resulting ellipsoidal detection volume were 18.5 x 12.0 x 10.0 µm3 at the Cu K-edge. The confocal µ-XANES mode is applied in the 3D resolved study of mineral inclusions in rare natural diamonds at the Fe K edge.
Please use this url to cite or link to this publication:
author
organization
year
type
journalArticle (original)
publication status
published
subject
keyword
polycapillary half-lens, confocal µ-XANES, µ-XAS, µ-XANES, MATO-GROSSO STATE, SUPERDEEP DIAMONDS, JUINA AREA, MANTLE, BRAZIL, SYNCHROTRON, INCLUSIONS
journal title
PHYSICAL CHEMISTRY CHEMICAL PHYSICS
Phys. Chem. Chem. Phys.
editor
Jeroen Anton van Bokhoven
volume
12
issue
21
issue title
Recent developments in X-ray absorption spectroscopy
pages
5653 - 5659
Web of Science type
Article
Web of Science id
000277926500015
JCR category
PHYSICS, ATOMIC, MOLECULAR & CHEMICAL
JCR impact factor
3.453 (2010)
JCR rank
4/31 (2010)
JCR quartile
1 (2010)
ISSN
1463-9076
DOI
10.1039/c004103n
language
English
UGent publication?
yes
classification
A1
copyright statement
I have transferred the copyright for this publication to the publisher
id
1073813
handle
http://hdl.handle.net/1854/LU-1073813
date created
2010-11-16 11:48:30
date last changed
2010-11-17 12:07:27
@article{1073813,
  abstract     = {A confocal setup based on polycapillary half-lenses was used to demonstrate three-dimensional (3D) spatially resolved {\textmu}-XANES in fluorescence detection mode at the DUBBLE XAS station of the ESRF (BM26A). The incoming beam was focused using a polycapillary half-lens and a second glass polycapillary was placed in front of the energy dispersive detector to  establish the confocal detection. The full-width-half-maxima along the main axes of the resulting ellipsoidal detection volume were 18.5 x 12.0 x 10.0 {\textmu}m3 at the Cu K-edge. The confocal {\textmu}-XANES mode is applied in the 3D resolved study of mineral inclusions in rare natural diamonds at the Fe K edge.},
  author       = {Silversmit, Geert and Vekemans, Bart and Nikitenko, Sergey and Schmitz, Sylvia and Schoonjans, Tom and Brenker, Frank E and Vincze, Laszlo},
  editor       = {van Bokhoven, Jeroen Anton},
  issn         = {1463-9076},
  journal      = {PHYSICAL CHEMISTRY CHEMICAL PHYSICS},
  keyword      = {polycapillary half-lens,confocal {\textmu}-XANES,{\textmu}-XAS,{\textmu}-XANES,MATO-GROSSO STATE,SUPERDEEP DIAMONDS,JUINA AREA,MANTLE,BRAZIL,SYNCHROTRON,INCLUSIONS},
  language     = {eng},
  number       = {21},
  pages        = {5653--5659},
  title        = {Spatially resolved 3D micro-XANES by a confocal detection scheme},
  url          = {http://dx.doi.org/10.1039/c004103n},
  volume       = {12},
  year         = {2010},
}

Chicago
Silversmit, Geert, Bart Vekemans, Sergey Nikitenko, Sylvia Schmitz, Tom Schoonjans, Frank E Brenker, and Laszlo Vincze. 2010. “Spatially Resolved 3D micro-XANES by a Confocal Detection Scheme.” Ed. Jeroen Anton van Bokhoven. Physical Chemistry Chemical Physics 12 (21): 5653–5659.
APA
Silversmit, G., Vekemans, B., Nikitenko, S., Schmitz, S., Schoonjans, T., Brenker, F. E., & Vincze, L. (2010). Spatially resolved 3D micro-XANES by a confocal detection scheme. (J. A. van Bokhoven, Ed.)PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 12(21), 5653–5659.
Vancouver
1.
Silversmit G, Vekemans B, Nikitenko S, Schmitz S, Schoonjans T, Brenker FE, et al. Spatially resolved 3D micro-XANES by a confocal detection scheme. van Bokhoven JA, editor. PHYSICAL CHEMISTRY CHEMICAL PHYSICS. 2010;12(21):5653–9.
MLA
Silversmit, Geert, Bart Vekemans, Sergey Nikitenko, et al. “Spatially Resolved 3D micro-XANES by a Confocal Detection Scheme.” Ed. Jeroen Anton van Bokhoven. PHYSICAL CHEMISTRY CHEMICAL PHYSICS 12.21 (2010): 5653–5659. Print.