Influence of bus voltage variations on two Maximum Power Point control loops

Koen Martens (UGent) , Bart Meersman (UGent) , Jeroen De Kooning (UGent) , Bert Renders (UGent) and Lieven Vandevelde (UGent)
Author
Organization
Abstract
An increasing amount of converter-connected distributed generators (DG) inject electrical energy in the power grid. On the other hand the increasing amount of non-linear and unbalanced loads put the power grid under increasing stress. Therefore, it is important not only to maximize the power output of the DG's through Maximum Power Point Tracking, but also to minimize the harmonic voltage and harmonic current distortion of the power system. In this article the interaction between the control system injecting the power in the grid and the control system maximizing the power output of the solar array is examined.
Keywords
full-bridge bidirectional converter, damping control strategy, photovoltaic array, MPPT, MPP control loop

Downloads

  • (...).pdf
    • full text
    • |
    • UGent only
    • |
    • PDF
    • |
    • 831.38 KB

Citation

Please use this url to cite or link to this publication:

Chicago
Martens, Koen, Bart Meersman, Jeroen De Kooning, Bert Renders, and Lieven Vandevelde. 2010. “Influence of Bus Voltage Variations on Two Maximum Power Point Control Loops.” In Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP). New York, NY, USA: IEEE.
APA
Martens, Koen, Meersman, B., De Kooning, J., Renders, B., & Vandevelde, L. (2010). Influence of bus voltage variations on two Maximum Power Point control loops. Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP). Presented at the 14th IEEE International conference on Harmonics and Quality of Power (ICHQP), New York, NY, USA: IEEE.
Vancouver
1.
Martens K, Meersman B, De Kooning J, Renders B, Vandevelde L. Influence of bus voltage variations on two Maximum Power Point control loops. Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP). New York, NY, USA: IEEE; 2010.
MLA
Martens, Koen, Bart Meersman, Jeroen De Kooning, et al. “Influence of Bus Voltage Variations on Two Maximum Power Point Control Loops.” Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP). New York, NY, USA: IEEE, 2010. Print.
@inproceedings{1047689,
  abstract     = {An increasing amount of converter-connected distributed generators (DG) inject electrical energy in the power grid. On the other hand the increasing amount of non-linear and unbalanced loads put the power grid under increasing stress. Therefore, it is important not only to maximize the power output of the DG's through Maximum Power Point Tracking, but also to minimize the harmonic voltage and harmonic current distortion of the power system. In this article the interaction between the control system injecting the power in the grid and the control system maximizing the power output of the solar array is examined.},
  author       = {Martens, Koen and Meersman, Bart and De Kooning, Jeroen and Renders, Bert and Vandevelde, Lieven},
  booktitle    = {Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP)},
  language     = {eng},
  location     = {Bergamo, Italy},
  pages        = {6},
  publisher    = {IEEE},
  title        = {Influence of bus voltage variations on two Maximum Power Point control loops},
  year         = {2010},
}