Ghent University Academic Bibliography

Advanced

Influence of bus voltage variations on two Maximum Power Point control loops

Koen Martens UGent, Bart Meersman UGent, Jeroen De Kooning UGent, Bert Renders UGent and Lieven Vandevelde UGent (2010) Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP).
abstract
An increasing amount of converter-connected distributed generators (DG) inject electrical energy in the power grid. On the other hand the increasing amount of non-linear and unbalanced loads put the power grid under increasing stress. Therefore, it is important not only to maximize the power output of the DG's through Maximum Power Point Tracking, but also to minimize the harmonic voltage and harmonic current distortion of the power system. In this article the interaction between the control system injecting the power in the grid and the control system maximizing the power output of the solar array is examined.
Please use this url to cite or link to this publication:
author
organization
year
type
conference
publication status
published
subject
keyword
full-bridge bidirectional converter, damping control strategy, photovoltaic array, MPPT, MPP control loop
in
Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP)
pages
6 pages
publisher
IEEE
place of publication
New York, NY, USA
conference name
14th IEEE International conference on Harmonics and Quality of Power (ICHQP)
conference location
Bergamo, Italy
conference start
2010-09-26
conference end
2010-09-29
language
English
UGent publication?
yes
classification
C1
copyright statement
I have transferred the copyright for this publication to the publisher
id
1047689
handle
http://hdl.handle.net/1854/LU-1047689
date created
2010-09-30 11:23:26
date last changed
2010-09-30 16:28:22
@inproceedings{1047689,
  abstract     = {An increasing amount of converter-connected distributed generators (DG) inject electrical energy in the power grid. On the other hand the increasing amount of non-linear and unbalanced loads put the power grid under increasing stress. Therefore, it is important not only to maximize the power output of the DG's through Maximum Power Point Tracking, but also to minimize the harmonic voltage and harmonic current distortion of the power system. In this article the interaction between the control system injecting the power in the grid and the control system maximizing the power output of the solar array is examined.},
  author       = {Martens, Koen and Meersman, Bart and De Kooning, Jeroen and Renders, Bert and Vandevelde, Lieven},
  booktitle    = {Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP)},
  keyword      = {full-bridge bidirectional converter,damping control strategy,photovoltaic array,MPPT,MPP control loop},
  language     = {eng},
  location     = {Bergamo, Italy},
  pages        = {6},
  publisher    = {IEEE},
  title        = {Influence of bus voltage variations on two Maximum Power Point control loops},
  year         = {2010},
}

Chicago
Martens, Koen, Bart Meersman, Jeroen De Kooning, Bert Renders, and Lieven Vandevelde. 2010. “Influence of Bus Voltage Variations on Two Maximum Power Point Control Loops.” In Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP). New York, NY, USA: IEEE.
APA
Martens, K., Meersman, B., De Kooning, J., Renders, B., & Vandevelde, L. (2010). Influence of bus voltage variations on two Maximum Power Point control loops. Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP). Presented at the 14th IEEE International conference on Harmonics and Quality of Power (ICHQP), New York, NY, USA: IEEE.
Vancouver
1.
Martens K, Meersman B, De Kooning J, Renders B, Vandevelde L. Influence of bus voltage variations on two Maximum Power Point control loops. Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP). New York, NY, USA: IEEE; 2010.
MLA
Martens, Koen, Bart Meersman, Jeroen De Kooning, et al. “Influence of Bus Voltage Variations on Two Maximum Power Point Control Loops.” Proceedings of the the 14th IEEE International Conference on Harmonics and Quality of Power (ICHQP). New York, NY, USA: IEEE, 2010. Print.