
A Rogowski-Chattock coil for local magnetic field measurements: sources of error
- Author
- Ahmed Mohamed Abouelyazied Abdallh (UGent) and Luc Dupré (UGent)
- Organization
- Abstract
- A magnetic field can be measured on a space scale of a few millimeters by means of magnetic sensors, such as a Rogowski–Chattock coil. The main advantage of the Rogowski coil is its capability to measure the field strength directly at the sample surface because both ends of the coil can be installed very close to the specimen surface. However, the measurements are affected by numerous errors, which are comprehensively discussed in this note.
- Keywords
- measurements errors, local magnetic measurements, Rogowski-Chattock coil
Downloads
-
(...).pdf
- full text
- |
- UGent only
- |
- |
- 377.58 KB
Citation
Please use this url to cite or link to this publication: http://hdl.handle.net/1854/LU-1043472
- MLA
- Mohamed Abouelyazied Abdallh, Ahmed, and Luc Dupré. “A Rogowski-Chattock Coil for Local Magnetic Field Measurements: Sources of Error.” MEASUREMENT SCIENCE & TECHNOLOGY 21.10 (2010): n. pag. Print.
- APA
- Mohamed Abouelyazied Abdallh, A., & Dupré, L. (2010). A Rogowski-Chattock coil for local magnetic field measurements: sources of error. MEASUREMENT SCIENCE & TECHNOLOGY, 21(10).
- Chicago author-date
- Mohamed Abouelyazied Abdallh, Ahmed, and Luc Dupré. 2010. “A Rogowski-Chattock Coil for Local Magnetic Field Measurements: Sources of Error.” Measurement Science & Technology 21 (10).
- Chicago author-date (all authors)
- Mohamed Abouelyazied Abdallh, Ahmed, and Luc Dupré. 2010. “A Rogowski-Chattock Coil for Local Magnetic Field Measurements: Sources of Error.” Measurement Science & Technology 21 (10).
- Vancouver
- 1.Mohamed Abouelyazied Abdallh A, Dupré L. A Rogowski-Chattock coil for local magnetic field measurements: sources of error. MEASUREMENT SCIENCE & TECHNOLOGY. 2010;21(10).
- IEEE
- [1]A. Mohamed Abouelyazied Abdallh and L. Dupré, “A Rogowski-Chattock coil for local magnetic field measurements: sources of error,” MEASUREMENT SCIENCE & TECHNOLOGY, vol. 21, no. 10, 2010.
@article{1043472, abstract = {A magnetic field can be measured on a space scale of a few millimeters by means of magnetic sensors, such as a Rogowski–Chattock coil. The main advantage of the Rogowski coil is its capability to measure the field strength directly at the sample surface because both ends of the coil can be installed very close to the specimen surface. However, the measurements are affected by numerous errors, which are comprehensively discussed in this note.}, articleno = {107003}, author = {Mohamed Abouelyazied Abdallh, Ahmed and Dupré, Luc}, issn = {0957-0233}, journal = {MEASUREMENT SCIENCE & TECHNOLOGY}, keywords = {measurements errors,local magnetic measurements,Rogowski-Chattock coil}, language = {eng}, number = {10}, pages = {5}, title = {A Rogowski-Chattock coil for local magnetic field measurements: sources of error}, url = {http://dx.doi.org/10.1088/0957-0233/21/10/107003}, volume = {21}, year = {2010}, }
- Altmetric
- View in Altmetric
- Web of Science
- Times cited: