Automated Cone Photoreceptor Detection in Adaptive Optics Flood Illumination Ophthalmoscopy
- Author
- Sander Wooning, Pam A.T. Heutinck, Kubra Liman, Sem Hennekam, Manon Van Haute (UGent) , Filip Van Den Broeck (UGent) , Bart Leroy (UGent) , Danuta M. Sampson, Danial Roshandel, Fred K. Chen, Daniel M. Pelt, L. Ingeborgh van den Born, Virginie J.M. Verhoeven, Caroline C.W. Klaver, Alberta A.H.J. Thiadens, Marine Durand, Nicolas Chateau, Theo van Walsum, Danilo Andrade De Jesus and Luisa Sanchez Brea
- Organization
- Abstract
- Purpose: To develop and validate a deep learning-based model for detecting cone photoreceptor cells in adaptive optics flood illumination ophthalmoscopy (AO-FIO). Design: Healthy volunteer study. Participants: A total of 36 healthy participants were included. Methods: The imaging protocol consisted of 21 AO-FIO images per eye acquired with the rtx1 adaptive optics retinal camera (Imagine Eyes), 4 degrees x 4 degrees each with 2 degrees overlap, imaging a retinal patch 4 degrees nasal (N) to 12 degrees temporal (T) and-5 degrees inferior to 5 degrees superior relative to the fovea. Each image was divided into patches of 128 x 128 pixels, with a 20-pixel overlap. A training set (625 patches) from 18 subjects (32 +/- 12 years, 6 males and 12 females) was annotated by a single center, whereas the test set (54 patches) from 18 subjects (40 +/- 16 years, 11 males and 7 females) was annotated by graders from 3 different institutions. The deep learning model, based on the U-Net architecture, underwent a parameter search using the tree-structured Parzen estimator. Main Outcome Measures: The F1 score was used to determine both intragrader and intergrader agreements and to evaluate the model's performance compared with the automated detection by the manufacturer's software (AOdetect Mosaic). Results: The average intragrader agreement was 0.85 +/- 0.06 between 2 degrees N and 2 degrees T, followed by 0.83 +/- 0.09 between 3 and 6 degrees T, and 0.80 +/- 0.10 between 7 and 10 degrees T. The average intergrader agreement for the 3 centers was 0.84 +/- 0.05, 0.79 +/- 0.05, and 0.76 +/- 0.06 at 2 degrees N-2 degrees T, 3-6 degrees T, and 7-10 degrees T, respectively. The best combination of hyperparameters based on the tree-structured Parzen estimator algorithm achieved an F1 score of 0.89 +/- 0.04. The average agreement between the model and the graders was 0.87 +/- 0.04, 0.85 +/- 0.03, and 0.81 +/- 0.03 at 2 degrees N-2 degrees T, 3 degrees-6 degrees T, and 7 degrees-10 degrees T, respectively. These values were higher than those between AOdetect's auto detection without manual correction and the graders (0.84 +/- 0.05, 0.79 +/- 0.03, and 0.68 +/- 0.04, respectively). A reduction in cone density was noted at greater eccentricities, in line with previous research findings, and the model indicated variations in estimating cell density for individuals aged 18 to 30 compared with those aged >= 50 years. Conclusions: The performance of the developed deep learning-based model, AO-FIO ConeDetect, was comparable to that of graders from 3 medical centers. It outperformed the manufacturers' software auto-detection, particularly at higher eccentricities (7 degrees-10 degrees T). Hence, the model could reduce the need for manual correction and enable faster cone mosaic analyses. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article. Ophthalmology Science 2025;5:100675 (c) 2024 by the American Academy of Ophthalmology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
- Keywords
- Adaptive optics, Cone photoreceptors, Automated cone detection, Retinal imaging, Flood illumination ophthalmoscopy, Image analysis, CELL SEGMENTATION, DENSITY
Downloads
-
publisher version.pdf
- full text (Published version)
- |
- open access
- |
- |
- 3.84 MB
Citation
Please use this url to cite or link to this publication: http://hdl.handle.net/1854/LU-01M6E7PYHQH5AT98MJKX0K8Y2E
- MLA
- Wooning, Sander, et al. “Automated Cone Photoreceptor Detection in Adaptive Optics Flood Illumination Ophthalmoscopy.” OPHTHALMOLOGY SCIENCE, vol. 5, no. 3, Elsevier BV, 2025, doi:10.1016/j.xops.2024.100675.
- APA
- Wooning, S., Heutinck, P. A. T., Liman, K., Hennekam, S., Van Haute, M., Van Den Broeck, F., … Sanchez Brea, L. (2025). Automated Cone Photoreceptor Detection in Adaptive Optics Flood Illumination Ophthalmoscopy. OPHTHALMOLOGY SCIENCE, 5(3). https://doi.org/10.1016/j.xops.2024.100675
- Chicago author-date
- Wooning, Sander, Pam A.T. Heutinck, Kubra Liman, Sem Hennekam, Manon Van Haute, Filip Van Den Broeck, Bart Leroy, et al. 2025. “Automated Cone Photoreceptor Detection in Adaptive Optics Flood Illumination Ophthalmoscopy.” OPHTHALMOLOGY SCIENCE 5 (3). https://doi.org/10.1016/j.xops.2024.100675.
- Chicago author-date (all authors)
- Wooning, Sander, Pam A.T. Heutinck, Kubra Liman, Sem Hennekam, Manon Van Haute, Filip Van Den Broeck, Bart Leroy, Danuta M. Sampson, Danial Roshandel, Fred K. Chen, Daniel M. Pelt, L. Ingeborgh van den Born, Virginie J.M. Verhoeven, Caroline C.W. Klaver, Alberta A.H.J. Thiadens, Marine Durand, Nicolas Chateau, Theo van Walsum, Danilo Andrade De Jesus, and Luisa Sanchez Brea. 2025. “Automated Cone Photoreceptor Detection in Adaptive Optics Flood Illumination Ophthalmoscopy.” OPHTHALMOLOGY SCIENCE 5 (3). doi:10.1016/j.xops.2024.100675.
- Vancouver
- 1.Wooning S, Heutinck PAT, Liman K, Hennekam S, Van Haute M, Van Den Broeck F, et al. Automated Cone Photoreceptor Detection in Adaptive Optics Flood Illumination Ophthalmoscopy. OPHTHALMOLOGY SCIENCE. 2025;5(3).
- IEEE
- [1]S. Wooning et al., “Automated Cone Photoreceptor Detection in Adaptive Optics Flood Illumination Ophthalmoscopy,” OPHTHALMOLOGY SCIENCE, vol. 5, no. 3, 2025.
@article{01M6E7PYHQH5AT98MJKX0K8Y2E,
abstract = {{Purpose: To develop and validate a deep learning-based model for detecting cone photoreceptor cells in adaptive optics flood illumination ophthalmoscopy (AO-FIO). Design: Healthy volunteer study. Participants: A total of 36 healthy participants were included. Methods: The imaging protocol consisted of 21 AO-FIO images per eye acquired with the rtx1 adaptive optics retinal camera (Imagine Eyes), 4 degrees x 4 degrees each with 2 degrees overlap, imaging a retinal patch 4 degrees nasal (N) to 12 degrees temporal (T) and-5 degrees inferior to 5 degrees superior relative to the fovea. Each image was divided into patches of 128 x 128 pixels, with a 20-pixel overlap. A training set (625 patches) from 18 subjects (32 +/- 12 years, 6 males and 12 females) was annotated by a single center, whereas the test set (54 patches) from 18 subjects (40 +/- 16 years, 11 males and 7 females) was annotated by graders from 3 different institutions. The deep learning model, based on the U-Net architecture, underwent a parameter search using the tree-structured Parzen estimator. Main Outcome Measures: The F1 score was used to determine both intragrader and intergrader agreements and to evaluate the model's performance compared with the automated detection by the manufacturer's software (AOdetect Mosaic). Results: The average intragrader agreement was 0.85 +/- 0.06 between 2 degrees N and 2 degrees T, followed by 0.83 +/- 0.09 between 3 and 6 degrees T, and 0.80 +/- 0.10 between 7 and 10 degrees T. The average intergrader agreement for the 3 centers was 0.84 +/- 0.05, 0.79 +/- 0.05, and 0.76 +/- 0.06 at 2 degrees N-2 degrees T, 3-6 degrees T, and 7-10 degrees T, respectively. The best combination of hyperparameters based on the tree-structured Parzen estimator algorithm achieved an F1 score of 0.89 +/- 0.04. The average agreement between the model and the graders was 0.87 +/- 0.04, 0.85 +/- 0.03, and 0.81 +/- 0.03 at 2 degrees N-2 degrees T, 3 degrees-6 degrees T, and 7 degrees-10 degrees T, respectively. These values were higher than those between AOdetect's auto detection without manual correction and the graders (0.84 +/- 0.05, 0.79 +/- 0.03, and 0.68 +/- 0.04, respectively). A reduction in cone density was noted at greater eccentricities, in line with previous research findings, and the model indicated variations in estimating cell density for individuals aged 18 to 30 compared with those aged >= 50 years. Conclusions: The performance of the developed deep learning-based model, AO-FIO ConeDetect, was comparable to that of graders from 3 medical centers. It outperformed the manufacturers' software auto-detection, particularly at higher eccentricities (7 degrees-10 degrees T). Hence, the model could reduce the need for manual correction and enable faster cone mosaic analyses. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article. Ophthalmology Science 2025;5:100675 (c) 2024 by the American Academy of Ophthalmology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).}},
articleno = {{100675}},
author = {{Wooning, Sander and Heutinck, Pam A.T. and Liman, Kubra and Hennekam, Sem and Van Haute, Manon and Van Den Broeck, Filip and Leroy, Bart and Sampson, Danuta M. and Roshandel, Danial and Chen, Fred K. and Pelt, Daniel M. and van den Born, L. Ingeborgh and Verhoeven, Virginie J.M. and Klaver, Caroline C.W. and Thiadens, Alberta A.H.J. and Durand, Marine and Chateau, Nicolas and van Walsum, Theo and Andrade De Jesus, Danilo and Sanchez Brea, Luisa}},
issn = {{2666-9145}},
journal = {{OPHTHALMOLOGY SCIENCE}},
keywords = {{Adaptive optics,Cone photoreceptors,Automated cone detection,Retinal imaging,Flood illumination ophthalmoscopy,Image analysis,CELL SEGMENTATION,DENSITY}},
language = {{eng}},
number = {{3}},
pages = {{13}},
publisher = {{Elsevier BV}},
title = {{Automated Cone Photoreceptor Detection in Adaptive Optics Flood Illumination Ophthalmoscopy}},
url = {{http://doi.org/10.1016/j.xops.2024.100675}},
volume = {{5}},
year = {{2025}},
}
- Altmetric
- View in Altmetric