Advanced search
1 file | 1.99 MB Add to list

EMT‐associated bias in the Parsortix® system observed with pancreatic cancer cell lines

Nele Vandenbussche (UGent) , Renske Imschoot (UGent) , Béatrice Lintermans (UGent) , Lode Denolf (UGent) , Joachim Taminau (UGent) , Charlotte Fieuws, Geert Berx (UGent) , Kris Gevaert (UGent) and Kathleen Claes (UGent)
(2025) MOLECULAR ONCOLOGY. 19. p.3360-3375
Author
Organization
Project
Abstract
Pancreatic cancer has a 5‐year survival rate of 12%, highlighting the need for reliable biomarkers for early detection and disease monitoring. Circulating tumor cells (CTCs) have emerged as a promising biomarker, yet their detection remains challenging. This study evaluates the Parsortix® system, a microfluidic device that enriches CTCs based on size and deformability, using pancreatic cancer cell lines. As increasing evidence indicates that during epithelial‐to‐mesenchymal transition (EMT) a cell's deformability increases, we evaluated possible biases by the device. The EMT stage of three pancreatic cancer cell lines, CAPAN‐1, MIA PaCa‐2, and PANC‐1, was assessed to classify them as epithelial, mesenchymal‐like, and hybrid, respectively. Spike‐in experiments showed that epithelial and hybrid phenotypes were more efficiently captured (62.6 ± 18.5% and 65.4 ± 11.1%) than mesenchymal‐like cancer cells (32.8 ± 10.2%). These results were confirmed using an EMT‐inducible breast cancer cell line. Lower recovery rates were found for the cells in a mesenchymal‐like state (31.5 ± 6.4%) than those in an epithelial state (47.56 ± 7.2%). In conclusion, the Parsortix® device may underestimate the number of mesenchymal CTCs.
Keywords
circulating tumor cells, EMT, liquid biopsy, pancreatic cancer, Parsortix, TO-MESENCHYMAL TRANSITION, CIRCULATING TUMOR-CELLS

Downloads

  • 5358 25Vandenbussche.pdf
    • full text (Published version)
    • |
    • open access
    • |
    • PDF
    • |
    • 1.99 MB

Citation

Please use this url to cite or link to this publication:

MLA
Vandenbussche, Nele, et al. “EMT‐associated Bias in the Parsortix® System Observed with Pancreatic Cancer Cell Lines.” MOLECULAR ONCOLOGY, vol. 19, 2025, pp. 3360–75, doi:10.1002/1878-0261.70066.
APA
Vandenbussche, N., Imschoot, R., Lintermans, B., Denolf, L., Taminau, J., Fieuws, C., … Claes, K. (2025). EMT‐associated bias in the Parsortix® system observed with pancreatic cancer cell lines. MOLECULAR ONCOLOGY, 19, 3360–3375. https://doi.org/10.1002/1878-0261.70066
Chicago author-date
Vandenbussche, Nele, Renske Imschoot, Béatrice Lintermans, Lode Denolf, Joachim Taminau, Charlotte Fieuws, Geert Berx, Kris Gevaert, and Kathleen Claes. 2025. “EMT‐associated Bias in the Parsortix® System Observed with Pancreatic Cancer Cell Lines.” MOLECULAR ONCOLOGY 19: 3360–75. https://doi.org/10.1002/1878-0261.70066.
Chicago author-date (all authors)
Vandenbussche, Nele, Renske Imschoot, Béatrice Lintermans, Lode Denolf, Joachim Taminau, Charlotte Fieuws, Geert Berx, Kris Gevaert, and Kathleen Claes. 2025. “EMT‐associated Bias in the Parsortix® System Observed with Pancreatic Cancer Cell Lines.” MOLECULAR ONCOLOGY 19: 3360–3375. doi:10.1002/1878-0261.70066.
Vancouver
1.
Vandenbussche N, Imschoot R, Lintermans B, Denolf L, Taminau J, Fieuws C, et al. EMT‐associated bias in the Parsortix® system observed with pancreatic cancer cell lines. MOLECULAR ONCOLOGY. 2025;19:3360–75.
IEEE
[1]
N. Vandenbussche et al., “EMT‐associated bias in the Parsortix® system observed with pancreatic cancer cell lines,” MOLECULAR ONCOLOGY, vol. 19, pp. 3360–3375, 2025.
@article{01JYGCAFHQ63KJFZ29RV1FXJB4,
  abstract     = {{Pancreatic cancer has a 5‐year survival rate of 12%, highlighting the need for reliable biomarkers for early detection and disease monitoring. Circulating tumor cells (CTCs) have emerged as a promising biomarker, yet their detection remains challenging. This study evaluates the Parsortix® system, a microfluidic device that enriches CTCs based on size and deformability, using pancreatic cancer cell lines. As increasing evidence indicates that during epithelial‐to‐mesenchymal transition (EMT) a cell's deformability increases, we evaluated possible biases by the device. The EMT stage of three pancreatic cancer cell lines, CAPAN‐1, MIA PaCa‐2, and PANC‐1, was assessed to classify them as epithelial, mesenchymal‐like, and hybrid, respectively. Spike‐in experiments showed that epithelial and hybrid phenotypes were more efficiently captured (62.6 ± 18.5% and 65.4 ± 11.1%) than mesenchymal‐like cancer cells (32.8 ± 10.2%). These results were confirmed using an EMT‐inducible breast cancer cell line. Lower recovery rates were found for the cells in a mesenchymal‐like state (31.5 ± 6.4%) than those in an epithelial state (47.56 ± 7.2%). In conclusion, the Parsortix® device may underestimate the number of mesenchymal CTCs.}},
  author       = {{Vandenbussche, Nele and Imschoot, Renske and Lintermans, Béatrice and Denolf, Lode and Taminau, Joachim and Fieuws, Charlotte and Berx, Geert and Gevaert, Kris and Claes, Kathleen}},
  issn         = {{1574-7891}},
  journal      = {{MOLECULAR ONCOLOGY}},
  keywords     = {{circulating tumor cells,EMT,liquid biopsy,pancreatic cancer,Parsortix,TO-MESENCHYMAL TRANSITION,CIRCULATING TUMOR-CELLS}},
  language     = {{eng}},
  pages        = {{3360--3375}},
  title        = {{EMT‐associated bias in the Parsortix® system observed with pancreatic cancer cell lines}},
  url          = {{http://doi.org/10.1002/1878-0261.70066}},
  volume       = {{19}},
  year         = {{2025}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: